Product description
121844 Euchner - Evaluation module and bus module MGB-L2...-PN (guard locking by solenoid force) with 3 control elements, push-pull plug
Product Details
- Weight 7.70073766 lb
- Series Spare parts
- Product Class Accessories
- PFHD 4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
- Mission time 20
- Safety Integrity Level SIL 3 (EN 62061:2005)
- Diagnostic Coverage (DC) 99
- B10D 0,13 x 10⁶
- Performance Level PL e
- Category 4
- Additional feature Incl. cover set ID. No. 120344
- Product version number V3.30.10
- Version Emergency stop illuminated
- Switching element 2 pos. driven NC
- Assignment diagram L0
- Bus data protocol Profinet (IEC 61158 type 10)
- Safety data protocol Profisafe (IEC 61784-3-3)
- Assured release distance Sar max.65 mm
- Fusing min.1 A Slow blow
- Degree of contamination (external, according to EN 60947-1) 3
- Auxiliary voltage DC 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Current consumption max.500 mA
- Transponder coding Unicode
- Safety class III
- Maximum feed-in current in the connection block max.4000 mA
- Connecting cable Profinet I/O cable, at least cat. 5e
- EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
- Rated impulse withstand voltage Uimp 0,5 kV
- Rated insulation voltage Ui 75 V
- Guard locking principle Open-circuit current principle
- Connection Push-pull RJ45 (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
- Locking force FZh 2000 N
- Weight 3,1 kg
- Mechanical life 0,1 x 10⁶
- Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
- Degree of protection IP54
- Reaction time max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
- Installation orientation Door hinge DIN left
- Shock and vibration resistance In acc. with EN 60947-5-3
- Switching frequency 0,25 Hz
- Ambient temperature -20 ... 55 °C
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121844 on MQ Automation is $2,930.28. Order now.
About the product
Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;2 illuminated pushbuttons;including adhesive labels;Push-pull plug;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode
Manufacturer warranty
121844 Euchner
$2,930.28
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$2,930.28
$2,930.28 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 121844 with other products
Weight
Series
Product Class
PFHD
Mission time
Safety Integrity Level
Diagnostic Coverage (DC)
B10D
Performance Level
Category
Additional feature
Product version number
Version
Switching element
Assignment diagram
Bus data protocol
Safety data protocol
Assured release distance ...
Fusing
Degree of contamination (...
Auxiliary voltage DC
Operating voltage DC
Current consumption
Transponder coding
Safety class
Maximum feed-in current i...
Connecting cable
EMC protection requiremen...
Rated impulse withstand v...
Rated insulation voltage ...
Guard locking principle
Connection
Locking force FZh
Mechanical life
Housing material
Degree of protection
Reaction time
Installation orientation
Shock and vibration resis...
Switching frequency
Ambient temperature
For the approval acc. to ...
Operating current
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Switching current
Type of output
Turn-on time
Switching load
Output voltage
Connection rating
Utilization category acc....
Overtravel
Test-pulse interval
Extraction force
Test pulses
Actuating force
Approach speed
Ready delay
Risk time according to EN...
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Selected product

121844
Euchner
121844 Euchner - Evaluation module and bus module MGB-L2...-PN (guard locking by solenoid force) wit...
Weight7.70073766 lb
SeriesSpare parts
Product ClassAccessories
PFHD4.07 x 10⁻⁸ (Fixed failure ...
Mission time20
Safety Integrity LevelSIL 3 (EN 62061:2005)
Diagnostic Coverage (DC)99
B10D0,13 x 10⁶
Performance LevelPL e
Category4
Additional featureIncl. cover set ID. No. 1203...
Product version numberV3.30.10
VersionEmergency stop illuminated
Switching element2 pos. driven NC
Assignment diagramL0
Bus data protocolProfinet (IEC 61158 type 10)
Safety data protocolProfisafe (IEC 61784-3-3)
Assured release distance Sarmax.65 mm
Fusingmin.1 A Slow blow
Degree of contamination (external, according to EN 60947-1)3
Auxiliary voltage DC24 V DC -15% ... +10% (Th...
Operating voltage DC24 V DC -15% ... 10% ((Re...
Current consumptionmax.500 mA
Transponder codingUnicode
Safety classIII
Maximum feed-in current in the connection blockmax.4000 mA
Connecting cableProfinet I/O cable, at least...
EMC protection requirementsIn accordance with EN 61000-...
Rated impulse withstand voltage Uimp0,5 kV
Rated insulation voltage Ui75 V
Guard locking principleOpen-circuit current princip...
ConnectionPush-pull RJ45 (X4 (The doc...
Locking force FZh2000 N
Mechanical life0,1 x 10⁶
Housing materialReinforced plastic, die-cast...
Degree of protectionIP54
Reaction timemax.250 ms Switch-off time...
Installation orientationDoor hinge DIN left
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching frequency0,25 Hz
Ambient temperature-20 ... 55 °C
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Switching current-
Type of output-
Turn-on time-
Switching load-
Output voltage-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Overtravel-
Test-pulse interval-
Extraction force-
Test pulses-
Actuating force-
Approach speed-
Ready delay-
Risk time according to EN 60947-5-3-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 121844?
The price of 121844 on MQ Automation is $2,930.28. Order now.
Out if stock but available for backorder.
121844 Euchner - Evaluation module and bus module MGB-L2...-PN (guard locking by solenoid force) with 3 control elements, push-pull plug
Similar products from: Safety Accessories
What can I help you find today?