121848 Euchner Safety Accessories

121848 on MQ Automation
Euchner
  • 121848
  • 121848

Part#:121848

Alt. Part#:MGB-L2B-PNA-R-121848

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121848 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, push-pull plug

Product Details

  • Weight
    7.67869146 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • B10D
    0,13 x 10⁶
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Category
    4
  • Performance Level
    PL e
  • Diagnostic Coverage (DC)
    99
  • Product version number
    V3.30.10
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    1NO
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Version
    Illuminated push buttons
  • Assignment diagram
    B1
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Fusing
    min.1 A Slow blow
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Transponder coding
    Unicode
  • Safety class
    III
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Current consumption
    max.500 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated insulation voltage Ui
    75 V
  • Guard locking principle
    Open-circuit current principle
  • Locking force FZh
    2000 N
  • Connection
    Push-pull power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Degree of protection
    IP54
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Installation orientation
    Door hinge DIN right
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    3,1 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121848 on MQ Automation is $2,930.28. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;2 illuminated pushbuttons;including adhesive labels;Push-pull plug;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

121848 Euchner

$2,930.28

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,930.28

$2,930.28 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121848 with other products

Weight

Series

Product Class

Mission time

B10D

Safety Integrity Level

Category

Performance Level

Diagnostic Coverage (DC)

Product version number

Additional feature

Switching element

PFHD

Safety data protocol

Version

Assignment diagram

Bus data protocol

Assured release distance ...

Fusing

Operating voltage DC

Auxiliary voltage DC

Transponder coding

Safety class

Connecting cable

Degree of contamination (...

EMC protection requiremen...

Current consumption

Rated impulse withstand v...

Maximum feed-in current i...

Rated insulation voltage ...

Guard locking principle

Locking force FZh

Connection

Degree of protection

Mechanical life

Switching frequency

Housing material

Installation orientation

Reaction time

Ambient temperature

Shock and vibration resis...

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

121848
0 in stock
121848
Euchner

121848 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) ...

Weight7.67869146 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

B10D0,13 x 10⁶

Safety Integrity LevelSIL 3 (EN 62061:2005)

Category4

Performance LevelPL e

Diagnostic Coverage (DC)99

Product version numberV3.30.10

Additional featureIncl. cover set ID. No. 1203...

Switching element1NO

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Safety data protocolProfisafe (IEC 61784-3-3)

VersionIlluminated push buttons

Assignment diagramB1

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Fusingmin.1 A Slow blow

Operating voltage DC24 V DC -15% ... 10% ((Re...

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Transponder codingUnicode

Safety classIII

Connecting cableProfinet I/O cable, at least...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Current consumptionmax.500 mA

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection blockmax.4000 mA

Rated insulation voltage Ui75 V

Guard locking principleOpen-circuit current princip...

Locking force FZh2000 N

ConnectionPush-pull power (X1 (The do...

Degree of protectionIP54

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Housing materialReinforced plastic, die-cast...

Installation orientationDoor hinge DIN right

Reaction timemax.550 ms Switch-off time...

Ambient temperature-20 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

Safety Integrity Level-

Category4

Performance LevelPL e

Diagnostic Coverage (DC)-

Product version number-

Additional feature-

Switching element2 pos. driven NC

PFHD4.1 x 10 ⁻⁹

Safety data protocol-

VersionEmergency stop

Assignment diagram-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Guard locking principle-

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Housing materialFiber glass reinforced therm...

Installation orientationDoor hinge DIN right

Reaction time-

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

B10D-

Safety Integrity Level-

Category4

Performance LevelPL e

Diagnostic Coverage (DC)-

Product version number-

Additional featureEscape release actuated by p...

Switching element-

PFHD4.1 x 10 ⁻⁹

Safety data protocol-

Version-

Assignment diagram-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Guard locking principleClosed-circuit current princ...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

Installation orientationAny

Reaction time-

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121848?
The price of 121848 on MQ Automation is $2,930.28. Order now.

Out if stock but available for backorder.

121848 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, push-pull plug

What can I help you find today?

Recommended parts