121831 Euchner Safety Accessories

121831 on MQ Automation
Euchner
  • 121831
  • 121831

Part#:121831

Alt. Part#:MGB-L1B-PNA-R-121831

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121831 Euchner - Evaluation module and bus module MGB-L1...-PN (guard locking by spring force) with 2 control elements, push-pull plug

Product Details

  • Weight
    7.5949159 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Mission time
    20
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Performance Level
    PL e
  • Category
    4
  • Diagnostic Coverage (DC)
    99
  • Product version number
    V3.30.10
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    1NO
  • Fusing
    min.1 A Slow blow
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assignment diagram
    B1
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Version
    Illuminated push buttons
  • Assured release distance Sar
    max.65 mm
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Transponder coding
    Unicode
  • Safety class
    III
  • Rated insulation voltage Ui
    75 V
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Current consumption
    max.500 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Locking force FZh
    2000 N
  • Guard locking principle
    Closed-circuit current principle
  • Mechanical life
    0,1 x 10⁶
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Installation orientation
    Door hinge DIN right
  • Connection
    Push-pull power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP54
  • Weight
    3,1 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121831 on MQ Automation is $2,826.20. Order now.


About the product

Guard locking with guard lock monitoring;2 illuminated pushbuttons;including adhesive labels;Push-pull plug;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

121831 Euchner

$2,826.20

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,826.20

$2,826.20 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121831 with other products

Weight

Series

Product Class

Safety Integrity Level

Mission time

PFHD

Performance Level

Category

Diagnostic Coverage (DC)

Product version number

Additional feature

Switching element

Fusing

Bus data protocol

Assignment diagram

Safety data protocol

Version

Assured release distance ...

Auxiliary voltage DC

Operating voltage DC

Connecting cable

Degree of contamination (...

EMC protection requiremen...

Transponder coding

Safety class

Rated insulation voltage ...

Maximum feed-in current i...

Current consumption

Rated impulse withstand v...

Locking force FZh

Guard locking principle

Mechanical life

Reaction time

Installation orientation

Connection

Housing material

Ambient temperature

Switching frequency

Degree of protection

Shock and vibration resis...

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN...

Solenoid duty cycle

Connection rating

Solenoid operating voltag...

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

121831
0 in stock
121831
Euchner

121831 Euchner - Evaluation module and bus module MGB-L1...-PN (guard locking by spring force) with ...

Weight7.5949159 lb

SeriesSpare parts

Product ClassAccessories

Safety Integrity LevelSIL 3 (EN 62061:2005)

Mission time20

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Performance LevelPL e

Category4

Diagnostic Coverage (DC)99

Product version numberV3.30.10

Additional featureIncl. cover set ID. No. 1203...

Switching element1NO

Fusingmin.1 A Slow blow

Bus data protocolProfinet (IEC 61158 type 10)

Assignment diagramB1

Safety data protocolProfisafe (IEC 61784-3-3)

VersionIlluminated push buttons

Assured release distance Sarmax.65 mm

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Connecting cableProfinet I/O cable, at least...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Transponder codingUnicode

Safety classIII

Rated insulation voltage Ui75 V

Maximum feed-in current in the connection blockmax.4000 mA

Current consumptionmax.500 mA

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh2000 N

Guard locking principleClosed-circuit current princ...

Mechanical life0,1 x 10⁶

Reaction timemax.550 ms Switch-off time...

Installation orientationDoor hinge DIN right

ConnectionPush-pull power (X1 (The do...

Housing materialReinforced plastic, die-cast...

Ambient temperature-20 ... 55 °C

Switching frequency0,25 Hz

Degree of protectionIP54

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Safety Integrity Level-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Diagnostic Coverage (DC)-

Product version number-

Additional featureEscape release actuated by p...

Switching element-

Fusing0,25 ... 8 A

Bus data protocol-

Assignment diagram-

Safety data protocol-

Version-

Assured release distance Sar-

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Transponder coding-

Safety classIII

Rated insulation voltage Ui50 V

Maximum feed-in current in the connection block-

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Reaction time-

Installation orientationAny

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Safety Integrity Level-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Diagnostic Coverage (DC)-

Product version number-

Additional feature-

Switching element2 pos. driven NC

Fusing0,25 ... 8 A

Bus data protocol-

Assignment diagram-

Safety data protocol-

VersionEmergency stop

Assured release distance Sar-

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Transponder coding-

Safety classIII

Rated insulation voltage Ui50 V

Maximum feed-in current in the connection block-

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh-

Guard locking principle-

Mechanical life1 x 10⁶

Reaction time-

Installation orientationDoor hinge DIN right

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating1 W

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121831?
The price of 121831 on MQ Automation is $2,826.20. Order now.

Out if stock but available for backorder.

121831 Euchner - Evaluation module and bus module MGB-L1...-PN (guard locking by spring force) with 2 control elements, push-pull plug

What can I help you find today?

Recommended parts