121846 Euchner Safety Accessories
Part#:121846
Alt. Part#:MGB-L1B-PNA-L-121846
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
121846 Euchner - Evaluation module and bus module MGB-L1...-PN (guard locking by spring force) with 3 control elements, push-pull plug
Product Details
- Weight 7.495708 lb
- Series Spare parts
- Product Class Accessories
- B10D 0,13 x 10⁶
- PFHD 4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
- Performance Level PL e
- Mission time 20
- Diagnostic Coverage (DC) 99
- Safety Integrity Level SIL 3 (EN 62061:2005)
- Category 4
- Product version number V3.30.10
- Additional feature Incl. cover set ID. No. 120344
- Bus data protocol Profinet (IEC 61158 type 10)
- Assured release distance Sar max.65 mm
- Version Emergency stop illuminated
- Safety data protocol Profisafe (IEC 61784-3-3)
- Switching element 2 pos. driven NC
- Assignment diagram B3
- Auxiliary voltage DC 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Degree of contamination (external, according to EN 60947-1) 3
- Safety class III
- Fusing min.1 A Slow blow
- Transponder coding Unicode
- Connecting cable Profinet I/O cable, at least cat. 5e
- EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
- Connection Push-pull power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
- Maximum feed-in current in the connection block max.4000 mA
- Rated impulse withstand voltage Uimp 0,5 kV
- Current consumption max.500 mA
- Locking force FZh 2000 N
- Switching frequency 0,25 Hz
- Guard locking principle Closed-circuit current principle
- Rated insulation voltage Ui 75 V
- Reaction time max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
- Ambient temperature -20 ... 55 °C
- Installation orientation Door hinge DIN left
- Mechanical life 0,1 x 10⁶
- Degree of protection IP54
- Weight 3,1 kg
- Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
- Shock and vibration resistance In acc. with EN 60947-5-3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121846 on MQ Automation is $2,930.28. Order now.
About the product
Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;2 illuminated pushbuttons;including adhesive labels;Push-pull plug;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode
Manufacturer warranty
121846 Euchner
$2,930.28
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$2,930.28
$2,930.28 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 121846 with other products
Weight
Series
Product Class
B10D
PFHD
Performance Level
Mission time
Diagnostic Coverage (DC)
Safety Integrity Level
Category
Product version number
Additional feature
Bus data protocol
Assured release distance ...
Version
Safety data protocol
Switching element
Assignment diagram
Auxiliary voltage DC
Operating voltage DC
Degree of contamination (...
Safety class
Fusing
Transponder coding
Connecting cable
EMC protection requiremen...
Connection
Maximum feed-in current i...
Rated impulse withstand v...
Current consumption
Locking force FZh
Switching frequency
Guard locking principle
Rated insulation voltage ...
Reaction time
Ambient temperature
Installation orientation
Mechanical life
Degree of protection
Housing material
Shock and vibration resis...
For the approval acc. to ...
Operating current
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Switching current
Type of output
Turn-on time
Switching load
Output voltage
Connection rating
Utilization category acc....
Overtravel
Test-pulse interval
Extraction force
Test pulses
Actuating force
Approach speed
Ready delay
Risk time according to EN...
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Selected product

121846
Euchner
121846 Euchner - Evaluation module and bus module MGB-L1...-PN (guard locking by spring force) with ...
Weight7.495708 lb
SeriesSpare parts
Product ClassAccessories
B10D0,13 x 10⁶
PFHD4.07 x 10⁻⁸ (Fixed failure ...
Performance LevelPL e
Mission time20
Diagnostic Coverage (DC)99
Safety Integrity LevelSIL 3 (EN 62061:2005)
Category4
Product version numberV3.30.10
Additional featureIncl. cover set ID. No. 1203...
Bus data protocolProfinet (IEC 61158 type 10)
Assured release distance Sarmax.65 mm
VersionEmergency stop illuminated
Safety data protocolProfisafe (IEC 61784-3-3)
Switching element2 pos. driven NC
Assignment diagramB3
Auxiliary voltage DC24 V DC -15% ... +10% (Th...
Operating voltage DC24 V DC -15% ... 10% ((Re...
Degree of contamination (external, according to EN 60947-1)3
Safety classIII
Fusingmin.1 A Slow blow
Transponder codingUnicode
Connecting cableProfinet I/O cable, at least...
EMC protection requirementsIn accordance with EN 61000-...
ConnectionPush-pull power (X1 (The do...
Maximum feed-in current in the connection blockmax.4000 mA
Rated impulse withstand voltage Uimp0,5 kV
Current consumptionmax.500 mA
Locking force FZh2000 N
Switching frequency0,25 Hz
Guard locking principleClosed-circuit current princ...
Rated insulation voltage Ui75 V
Reaction timemax.550 ms Switch-off time...
Ambient temperature-20 ... 55 °C
Installation orientationDoor hinge DIN left
Mechanical life0,1 x 10⁶
Degree of protectionIP54
Housing materialReinforced plastic, die-cast...
Shock and vibration resistanceIn acc. with EN 60947-5-3
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Switching current-
Type of output-
Turn-on time-
Switching load-
Output voltage-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Overtravel-
Test-pulse interval-
Extraction force-
Test pulses-
Actuating force-
Approach speed-
Ready delay-
Risk time according to EN 60947-5-3-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 121846?
The price of 121846 on MQ Automation is $2,930.28. Order now.
Out if stock but available for backorder.
121846 Euchner - Evaluation module and bus module MGB-L1...-PN (guard locking by spring force) with 3 control elements, push-pull plug
Similar products from: Safety Accessories
What can I help you find today?