161081 Euchner Safety Locking Systems

161081 on MQ Automation
Euchner
  • 161081
  • 161081
  • 161081

Part#:161081

Alt. Part#:MGBS-P-L2-AR-U-R-AEE-SH-161081

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

161081 Euchner - MGBS-AR, M23, 2 pushbutton, with escape release, door hinge on right

Product Details

  • Weight
    4.3871938 lb
  • Series
    MGBS-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • PFHD
    4.1 x 10 ⁻⁹
  • Category
    4
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Switching element
    1NO
  • Operating current
    1 ... 50 mA
  • Version
    Illuminated push buttons
  • Repeat accuracy R
    10 %
  • Power supply
    24 V
  • Additional feature
    Incl. cover set ID. No. 120344
  • Operating voltage
    UB V
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Switching current
    1 ... 150 mA
  • Output voltage
    0 ... 1 V DC
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid duty cycle
    100 %
  • Connection rating
    6 W
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    50 V
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    40 mA
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Test-pulse interval
    min.140 ms
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Actuating force
    10 N
  • Overtravel
    5 mm
  • Extraction force
    20 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Locking force Fmax
    3900 N
  • Retention force
    20 N
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Open-circuit current principle
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Installation orientation
    Door hinge DIN right
  • Weight
    1,5 kg
  • Ready delay
    8 s
  • Switching frequency
    max.0,5 Hz
  • Housing material
    Die-cast zinc
  • Ambient temperature
    -20 ... +55 °C
  • Mechanical life
    1 x 10⁶
  • Degree of protection
    IP65 (Screwed tight plug connector/mating component)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161081 on MQ Automation is $1,398.54. Order now.


About the product

Locking module (order handle module separately);Adjustable door hinge; factory setting: right;Series connection possible (up to 20 AR devices in series);Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;2 pushbuttons (illuminated);With plug connector M23;Unicode;Door position monitoring output;With escape release (order inner door handle separately)


Manufacturer warranty

161081 Euchner

$1,398.54

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,398.54

$1,398.54 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161081 with other products

Weight

Series

Product Class

Mission time

PFHD

Category

Performance Level

For the approval acc. to ...

Switching element

Operating current

Version

Repeat accuracy R

Power supply

Additional feature

Operating voltage

Discrepancy time

Turn-on time

Off-state current Ir

Switching current

Output voltage

Switching load

Type of output

Risk time according to EN...

Safety class

Degree of contamination (...

EMC protection requiremen...

Solenoid duty cycle

Connection rating

Rated impulse withstand v...

Rated insulation voltage ...

Solenoid operating voltag...

Test pulses

Fusing

Operating voltage DC

Current consumption

Utilization category acc....

Test-pulse interval

Extension of risk time ac...

Actuating force

Overtravel

Extraction force

Locking force FZh

Locking force Fmax

Retention force

Approach speed

Guard locking principle

Connection

Installation orientation

Ready delay

Switching frequency

Housing material

Ambient temperature

Mechanical life

Degree of protection

Shock and vibration resis...

B10D

Detent mechanism

Selected product

161081
0 in stock
161081
Euchner

161081 Euchner - MGBS-AR, M23, 2 pushbutton, with escape release, door hinge on right

Weight4.3871938 lb

SeriesMGBS-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Switching element1NO

Operating current1 ... 50 mA

VersionIlluminated push buttons

Repeat accuracy R10 %

Power supply24 V

Additional featureIncl. cover set ID. No. 1203...

Operating voltageUB V

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating6 W

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Test pulsesmax.1,0 ms (Applies for a l...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.140 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Actuating force10 N

Overtravel5 mm

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Retention force20 N

Approach speedmax.20 m/min

Guard locking principleOpen-circuit current princip...

Connection1 plug connector M23, 19-pin...

Installation orientationDoor hinge DIN right

Ready delay8 s

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Detent mechanism-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Switching element-

Operating current-

Version-

Repeat accuracy R10 %

Power supply-

Additional featureEscape release actuated by p...

Operating voltage-

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Output voltage0,8xUB ... UB V DC

Switching load24V DC, class 2 (Alternativ...

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating6 W

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Test pulsesmax.1,0 ms (Applies for a l...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.140 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Actuating force10 N

Overtravel5 mm

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Retention force20 N

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Ready delay8 s

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Detent mechanism-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Switching element2 pos. driven NC

Operating current1 ... 100 mA

VersionEmergency stop

Repeat accuracy R10 %

Power supply-

Additional feature-

Operating voltage5 ... 24 V

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle-

Connection rating1 W

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid operating voltage DC-

Test pulsesmax.0,3 ms (Applies for a l...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.100 ms

Extension of risk time according to EN 60947-5-3 per device-

Actuating force10 N

Overtravel5 mm

Extraction force20 N

Locking force FZh-

Locking force Fmax-

Retention force-

Approach speedmax.20 m/min

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Installation orientationDoor hinge DIN right

Ready delaymax.1 s

Switching frequencymax.0,5 Hz

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

Detent mechanismSnap-in bolt

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161081?
The price of 161081 on MQ Automation is $1,398.54. Order now.

Out if stock but available for backorder.

161081 Euchner - MGBS-AR, M23, 2 pushbutton, with escape release, door hinge on right

What can I help you find today?