161023 Euchner Safety Locking Systems

161023 on MQ Automation
Euchner
  • 161023
  • 161023

Part#:161023

Alt. Part#:MGB2-L2-BR-M-X0000-BX-161023

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

161023 Euchner - Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current principle)

Product Details

  • Series
    MGB2-L.-BR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Diagnostic Coverage (DC)
    99
  • Output current
    1 ... 150 mA
  • Performance Level
    PL e
  • PFHD
    2.95 x 10⁻⁹
  • Output voltage
    UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Product version number
    V1.0.3
  • Category
    4
  • Turn-on time
    max.80 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.5 ms
  • Operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Current consumption
    max.80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)
  • Transponder coding
    Multicode
  • Solenoid operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Risk time according to EN 60947-5-3
    max.50 ms (In a series connection, the risk time increases by 10 ms per each additional device.)
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Rated insulation voltage Ui
    75 V
  • Connection cross-section
    0,25 ... 1,5 mm² ((AWG 23 ... AWG 16))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Housing material
    Glass fiber reinforced plastic; die-cast zinc, nickel-plated
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Mechanical life
    0,1 x 10⁶
  • Ready delay
    5 s
  • Ambient temperature
    -25 ... 55 °C
  • Switching frequency
    0,25 Hz
  • Weight
    1,00 kg
  • Degree of protection
    IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)
  • Guard locking principle
    Open-circuit current principle

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161023 on MQ Automation is $849.33. Order now.


About the product

Guard locking for the protection of persons or processes;Locking module MGB2 for direct connection to a control system;Configurable as interlocking or guard locking;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Adjustable door hinge;Multicode;Compatible with BR technology


Manufacturer warranty

161023 Euchner

$849.33

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$849.33

$849.33 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161023 with other products

Series

Product Class

Mission time

Safety Integrity Level

Diagnostic Coverage (DC)

Output current

Performance Level

PFHD

Output voltage

Product version number

Category

Turn-on time

Type of output

Test-pulse interval

Test pulses

Operating voltage DC

Current consumption

Transponder coding

Solenoid operating voltag...

Risk time according to EN...

Discrepancy time

Safety class

Rated insulation voltage ...

Connection cross-section

Degree of contamination (...

Rated impulse withstand v...

Utilization category acc....

Locking force FZh

Housing material

Shock and vibration resis...

Mechanical life

Ready delay

Ambient temperature

Switching frequency

Weight

Degree of protection

Guard locking principle

For the approval acc. to ...

Additional feature

Repeat accuracy R

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Installation orientation

Assured release distance ...

Operating distance

Switching hysteresis

Assured operating distanc...

Rated conditional short-c...

Tightening torque

Static bending radius

Dynamic bending radius

Mounting distance

Mounting method

Cable ambient temperature...

Cable ambient temperature...

Selected product

161023
0 in stock
161023
Euchner

161023 Euchner - Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current ...

SeriesMGB2-L.-BR

Product ClassSafety System

Mission time20 y

Safety Integrity LevelSIL 3 (EN 62061:2005)

Diagnostic Coverage (DC)99

Output current1 ... 150 mA

Performance LevelPL e

PFHD2.95 x 10⁻⁹

Output voltageUB-2 ... UB V DC (Value at ...

Product version numberV1.0.3

Category4

Turn-on timemax.80 ms

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Test pulsesmax.5 ms

Operating voltage DC24 V DC -15% ... 15% ((Re...

Current consumptionmax.80 mA (at 20.4 V includ...

Transponder codingMulticode

Solenoid operating voltage DC24 V DC -15% ... 15% ((Re...

Risk time according to EN 60947-5-3max.50 ms (In a series conn...

Discrepancy timemax.10 ms

Safety classIII

Rated insulation voltage Ui75 V

Connection cross-section0,25 ... 1,5 mm² ((AWG 23 ....

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh2000 N

Housing materialGlass fiber reinforced plast...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mechanical life0,1 x 10⁶

Ready delay5 s

Ambient temperature-25 ... 55 °C

Switching frequency0,25 Hz

Weight1,00 kg

Degree of protectionIP65 (This is the case only...

Guard locking principleOpen-circuit current princip...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Installation orientation-

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

Output current-

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Output voltage0,8xUB ... UB V DC

Product version number-

Category4

Turn-on timemax.400 ms

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Transponder coding-

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Rated insulation voltage Ui50 V

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Housing materialDie-cast zinc

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mechanical life1 x 10⁶

Ready delay8 s

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Weight1.763696 lb

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Guard locking principleClosed-circuit current princ...

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

SeriesCES-AP

Product ClassSafety System

Mission time20

Safety Integrity Level-

Diagnostic Coverage (DC)-

Output current-

Performance LevelPL e

PFHD1.8 x 10⁻⁹

Output voltage0,8 x UB ... UB V DC

Product version number-

Category4

Turn-on timemax.300 ms

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.30 mA (Without taking i...

Transponder coding-

Solenoid operating voltage DC-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms

Safety classIII

Rated insulation voltage Ui75 V

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Housing materialPlastic, PBT

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mechanical life-

Ready delay0,5 s

Ambient temperature-

Switching frequencymax.1 Hz

Weight0.52029032 lb

Degree of protectionIP67, IP69K

Guard locking principle-

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Switching load-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connectionconnection cable PVC, length...

Installation orientationAny

Assured release distance Sarmax.60 mm

Operating distance19 mm

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Static bending radius5 x cable diameter

Dynamic bending radius10 x cable diameter

Mounting distancemin.400 mm

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161023?
The price of 161023 on MQ Automation is $849.33. Order now.

Out if stock but available for backorder.

161023 Euchner - Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current principle)

What can I help you find today?

Recommended parts