161021 Euchner Safety Locking Systems

161021 on MQ Automation
Euchner
  • 161021
  • 161021

Part#:161021

Alt. Part#:MGB2-L1-BR-M-X0000-BX-161021

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

161021 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit current principle)

Product Details

  • Weight
    2.5242899 lb
  • Series
    MGB2-L.-BR
  • Product Class
    Safety System
  • PFHD
    2.95 x 10⁻⁹
  • Diagnostic Coverage (DC)
    99
  • Mission time
    20 y
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Performance Level
    PL e
  • Category
    4
  • Turn-on time
    max.80 ms
  • Output current
    1 ... 150 mA
  • Product version number
    V1.0.3
  • Output voltage
    UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Test pulses
    max.5 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Current consumption
    max.80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)
  • Solenoid operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Multicode
  • Risk time according to EN 60947-5-3
    max.50 ms (In a series connection, the risk time increases by 10 ms per each additional device.)
  • Discrepancy time
    max.10 ms
  • Connection cross-section
    0,25 ... 1,5 mm²
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Locking force FZh
    2000 N
  • Rated insulation voltage Ui
    75 V
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Degree of protection
    IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)
  • Mechanical life
    0,1 x 10⁶
  • Ready delay
    5 s
  • Guard locking principle
    Closed-circuit current principle
  • Switching frequency
    0,25 Hz
  • Housing material
    Glass fiber reinforced plastic; die-cast zinc, nickel-plated
  • Ambient temperature
    -25 ... 55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Weight
    1,00 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161021 on MQ Automation is $849.33. Order now.


About the product

Guard locking for the protection of persons or processes;Locking module MGB2 for direct connection to a control system;Configurable as interlocking or guard locking;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Adjustable door hinge;Multicode;Compatible with BR technology


Manufacturer warranty

161021 Euchner

$849.33

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$849.33

$849.33 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161021 with other products

Weight

Series

Product Class

PFHD

Diagnostic Coverage (DC)

Mission time

Safety Integrity Level

Performance Level

Category

Turn-on time

Output current

Product version number

Output voltage

Test pulses

Type of output

Test-pulse interval

Current consumption

Solenoid operating voltag...

Operating voltage DC

Transponder coding

Risk time according to EN...

Discrepancy time

Connection cross-section

Rated impulse withstand v...

Safety class

Degree of contamination (...

Locking force FZh

Rated insulation voltage ...

Utilization category acc....

Degree of protection

Mechanical life

Ready delay

Guard locking principle

Switching frequency

Housing material

Ambient temperature

Shock and vibration resis...

For the approval acc. to ...

Additional feature

Repeat accuracy R

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Installation orientation

Assured release distance ...

Operating distance

Switching hysteresis

Assured operating distanc...

Rated conditional short-c...

Tightening torque

Static bending radius

Dynamic bending radius

Mounting distance

Mounting method

Cable ambient temperature...

Cable ambient temperature...

Selected product

161021
0 in stock
161021
Euchner

161021 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit curren...

Weight2.5242899 lb

SeriesMGB2-L.-BR

Product ClassSafety System

PFHD2.95 x 10⁻⁹

Diagnostic Coverage (DC)99

Mission time20 y

Safety Integrity LevelSIL 3 (EN 62061:2005)

Performance LevelPL e

Category4

Turn-on timemax.80 ms

Output current1 ... 150 mA

Product version numberV1.0.3

Output voltageUB-2 ... UB V DC (Value at ...

Test pulsesmax.5 ms

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Current consumptionmax.80 mA (at 20.4 V includ...

Solenoid operating voltage DC24 V DC -15% ... 15% ((Re...

Operating voltage DC24 V DC -15% ... 15% ((Re...

Transponder codingMulticode

Risk time according to EN 60947-5-3max.50 ms (In a series conn...

Discrepancy timemax.10 ms

Connection cross-section0,25 ... 1,5 mm²

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Locking force FZh2000 N

Rated insulation voltage Ui75 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Degree of protectionIP65 (This is the case only...

Mechanical life0,1 x 10⁶

Ready delay5 s

Guard locking principleClosed-circuit current princ...

Switching frequency0,25 Hz

Housing materialGlass fiber reinforced plast...

Ambient temperature-25 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Installation orientation-

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

Mission time20 y

Safety Integrity Level-

Performance LevelPL e

Category4

Turn-on timemax.400 ms

Output current-

Product version number-

Output voltage0,8xUB ... UB V DC

Test pulsesmax.1,0 ms (Applies for a l...

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Current consumption40 mA

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Connection cross-section-

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Ready delay8 s

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

PFHD1.8 x 10⁻⁹

Diagnostic Coverage (DC)-

Mission time20

Safety Integrity Level-

Performance LevelPL e

Category4

Turn-on timemax.300 ms

Output current-

Product version number-

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.0,3 ms (Applies for a l...

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.100 ms

Current consumptionmax.30 mA (Without taking i...

Solenoid operating voltage DC-

Operating voltage DC24 V DC 15% ... 15% Regu...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms

Connection cross-section-

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Locking force FZh-

Rated insulation voltage Ui75 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Degree of protectionIP67, IP69K

Mechanical life-

Ready delay0,5 s

Guard locking principle-

Switching frequencymax.1 Hz

Housing materialPlastic, PBT

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Switching load-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connectionconnection cable PVC, length...

Installation orientationAny

Assured release distance Sarmax.60 mm

Operating distance19 mm

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Static bending radius5 x cable diameter

Dynamic bending radius10 x cable diameter

Mounting distancemin.400 mm

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161021?
The price of 161021 on MQ Automation is $849.33. Order now.

Out if stock but available for backorder.

161021 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit current principle)

What can I help you find today?

Recommended parts