161027 Euchner Safety Locking Systems

161027 on MQ Automation
Euchner
  • 161027
  • 161027

Part#:161027

Alt. Part#:MGB2-L1-BR-M-X0000-BJ-161027

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

161027 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit current principle)

Product Details

  • Weight
    2.5904285 lb
  • Series
    MGB2-L.-BR
  • Product Class
    Safety System
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Mission time
    20 y
  • PFHD
    2.95 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Diagnostic Coverage (DC)
    99
  • Product version number
    V1.0.3
  • Turn-on time
    max.80 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.5 ms
  • Output current
    1 ... 150 mA
  • Output voltage
    UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Solenoid operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Current consumption
    max.80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)
  • Operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Risk time according to EN 60947-5-3
    max.50 ms (In a series connection, the risk time increases by 10 ms per each additional device.)
  • Safety class
    III
  • Transponder coding
    Multicode
  • Connection cross-section
    0,25 ... 0,75 mm²
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Discrepancy time
    max.10 ms
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    75 V
  • Locking force FZh
    2000 N
  • Connection
    Other connection option to X5 / X6 available
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Guard locking principle
    Closed-circuit current principle
  • Ambient temperature
    -25 ... 55 °C
  • Ready delay
    5 s
  • Housing material
    Glass fiber reinforced plastic; die-cast zinc, nickel-plated
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Weight
    1,00 kg
  • Degree of protection
    IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161027 on MQ Automation is $1,042.96. Order now.


About the product

Guard locking for the protection of persons or processes;Locking module MGB2 for direct connection to a control system;Configurable as interlocking or guard locking;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Connection for signal light/enabling switch;Adjustable door hinge;Multicode;Compatible with BR technology


Manufacturer warranty

161027 Euchner

$1,042.96

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,042.96

$1,042.96 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161027 with other products

Weight

Series

Product Class

Safety Integrity Level

Mission time

PFHD

Performance Level

Category

Diagnostic Coverage (DC)

Product version number

Turn-on time

Type of output

Test-pulse interval

Test pulses

Output current

Output voltage

Solenoid operating voltag...

Current consumption

Operating voltage DC

Risk time according to EN...

Safety class

Transponder coding

Connection cross-section

Degree of contamination (...

Rated impulse withstand v...

Discrepancy time

Utilization category acc....

Rated insulation voltage ...

Locking force FZh

Connection

Shock and vibration resis...

Guard locking principle

Ambient temperature

Ready delay

Housing material

Mechanical life

Switching frequency

Degree of protection

For the approval acc. to ...

Additional feature

Repeat accuracy R

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Installation orientation

Assured release distance ...

Operating distance

Switching hysteresis

Assured operating distanc...

Rated conditional short-c...

Tightening torque

Static bending radius

Dynamic bending radius

Mounting distance

Mounting method

Cable ambient temperature...

Cable ambient temperature...

Selected product

161027
0 in stock
161027
Euchner

161027 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit curren...

Weight2.5904285 lb

SeriesMGB2-L.-BR

Product ClassSafety System

Safety Integrity LevelSIL 3 (EN 62061:2005)

Mission time20 y

PFHD2.95 x 10⁻⁹

Performance LevelPL e

Category4

Diagnostic Coverage (DC)99

Product version numberV1.0.3

Turn-on timemax.80 ms

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Test pulsesmax.5 ms

Output current1 ... 150 mA

Output voltageUB-2 ... UB V DC (Value at ...

Solenoid operating voltage DC24 V DC -15% ... 15% ((Re...

Current consumptionmax.80 mA (at 20.4 V includ...

Operating voltage DC24 V DC -15% ... 15% ((Re...

Risk time according to EN 60947-5-3max.50 ms (In a series conn...

Safety classIII

Transponder codingMulticode

Connection cross-section0,25 ... 0,75 mm²

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui75 V

Locking force FZh2000 N

ConnectionOther connection option to X...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Guard locking principleClosed-circuit current princ...

Ambient temperature-25 ... 55 °C

Ready delay5 s

Housing materialGlass fiber reinforced plast...

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Degree of protectionIP65 (This is the case only...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Installation orientation-

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Safety Integrity Level-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Diagnostic Coverage (DC)-

Product version number-

Turn-on timemax.400 ms

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Output current-

Output voltage0,8xUB ... UB V DC

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Transponder coding-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Discrepancy timemax.10 ms In acc. with EN ...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Guard locking principleClosed-circuit current princ...

Ambient temperature-20 ... +55 °C

Ready delay8 s

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Installation orientationAny

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Safety Integrity Level-

Mission time20

PFHD1.8 x 10⁻⁹

Performance LevelPL e

Category4

Diagnostic Coverage (DC)-

Product version number-

Turn-on timemax.300 ms

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Output current-

Output voltage0,8 x UB ... UB V DC

Solenoid operating voltage DC-

Current consumptionmax.30 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Transponder coding-

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui75 V

Locking force FZh-

Connectionconnection cable PVC, length...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Guard locking principle-

Ambient temperature-

Ready delay0,5 s

Housing materialPlastic, PBT

Mechanical life-

Switching frequencymax.1 Hz

Degree of protectionIP67, IP69K

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Switching load-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Installation orientationAny

Assured release distance Sarmax.60 mm

Operating distance19 mm

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Static bending radius5 x cable diameter

Dynamic bending radius10 x cable diameter

Mounting distancemin.400 mm

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161027?
The price of 161027 on MQ Automation is $1,042.96. Order now.

Out if stock but available for backorder.

161027 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit current principle)

What can I help you find today?

Recommended parts