136553 Euchner Safety Accessories

136553 on MQ Automation
Euchner
  • 136553
  • 136553
  • 136553

Part#:136553

Alt. Part#:MGB-L0B-EIA-R-136553

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

136553 Euchner - Interlocking module MGB-L0...-EI with 2 pushbuttons, emergency stop

Product Details

  • Series
    MGB-EI
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Mission time
    20
  • Diagnostic Coverage (DC)
    99
  • PFHD
    3.37 x 10⁻⁹ (Fixed failure rate without consideration of faults in wearing parts.)
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Performance Level
    PL e
  • Category
    4
  • Switching element
    2 pos. driven NC
  • Additional feature
    Incl. cover set ID. No. 120344
  • Product version number
    V1.2
  • Version
    Emergency stop illuminated
  • Special features
    With adhesive ring
  • Safety data protocol
    CIP Safety
  • Assignment diagram
    B0
  • Assured release distance Sar
    max.65 mm
  • Bus data protocol
    Ethernet/IP
  • Fusing
    min.1 A Slow blow
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Transponder coding
    Unicode
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Connecting cable
    Ethernet/IP cable, Cat. 5e min.
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    75 V
  • Current consumption
    max.500 mA
  • Switching frequency
    0,25 Hz
  • Connection
    M12 Power, A-coded (X1)
  • Ambient temperature
    -20 ... 55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Degree of protection
    IP54
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Mechanical life
    0,1 x 10⁶
  • Weight
    3,1 kg
  • Installation orientation
    Door hinge DIN right

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


About the product

Interlocking (without guard locking);Emergency stop according to ISO 13850, illuminated;2 illuminated pushbuttons;including adhesive labels;Connection via M12 plug;Pre-assembled on mounting plates;Unicode


Manufacturer warranty

136553 Euchner

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 136553 with other products

Series

Product Class

B10D

Mission time

Diagnostic Coverage (DC)

PFHD

Safety Integrity Level

Performance Level

Category

Switching element

Additional feature

Product version number

Version

Special features

Safety data protocol

Assignment diagram

Assured release distance ...

Bus data protocol

Fusing

Operating voltage DC

Auxiliary voltage DC

Transponder coding

Safety class

Degree of contamination (...

EMC protection requiremen...

Connecting cable

Maximum feed-in current i...

Rated impulse withstand v...

Rated insulation voltage ...

Current consumption

Switching frequency

Connection

Ambient temperature

Shock and vibration resis...

Reaction time

Degree of protection

Housing material

Mechanical life

Weight

Installation orientation

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Locking force FZh

Guard locking principle

Selected product

136553
0 in stock
136553
Euchner

136553 Euchner - Interlocking module MGB-L0...-EI with 2 pushbuttons, emergency stop

SeriesMGB-EI

Product ClassAccessories

B10D0,13 x 10⁶

Mission time20

Diagnostic Coverage (DC)99

PFHD3.37 x 10⁻⁹ (Fixed failure ...

Safety Integrity LevelSIL 3 (EN 62061:2005)

Performance LevelPL e

Category4

Switching element2 pos. driven NC

Additional featureIncl. cover set ID. No. 1203...

Product version numberV1.2

VersionEmergency stop illuminated

Special featuresWith adhesive ring

Safety data protocolCIP Safety

Assignment diagramB0

Assured release distance Sarmax.65 mm

Bus data protocolEthernet/IP

Fusingmin.1 A Slow blow

Operating voltage DC24 V DC -15% ... 10% ((Re...

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Transponder codingUnicode

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Connecting cableEthernet/IP cable, Cat. 5e m...

Maximum feed-in current in the connection blockmax.4000 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui75 V

Current consumptionmax.500 mA

Switching frequency0,25 Hz

ConnectionM12 Power, A-coded (X1)

Ambient temperature-20 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction timemax.250 ms Switch-off time...

Degree of protectionIP54

Housing materialReinforced plastic, die-cast...

Mechanical life0,1 x 10⁶

Weight3,1 kg

Installation orientationDoor hinge DIN right

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Safety Integrity Level-

Performance LevelPL e

Category4

Switching element2 pos. driven NC

Additional feature-

Product version number-

VersionEmergency stop

Special features-

Safety data protocol-

Assignment diagram-

Assured release distance Sar-

Bus data protocol-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connecting cable-

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction time-

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Weight3.968316 lb

Installation orientationDoor hinge DIN right

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Safety Integrity Level-

Performance LevelPL e

Category4

Switching element-

Additional featureEscape release actuated by p...

Product version number-

Version-

Special features-

Safety data protocol-

Assignment diagram-

Assured release distance Sar-

Bus data protocol-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connecting cable-

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction time-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Weight1.763696 lb

Installation orientationAny

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

136553 Euchner - Interlocking module MGB-L0...-EI with 2 pushbuttons, emergency stop

What can I help you find today?

Recommended parts