117330 Euchner Safety Proximity Sensors

117330 on MQ Automation
Euchner
  • 117330
  • 117330
  • 117330

Part#:117330

Alt. Part#:CES-I-AP-M-C04-U20-117330

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

117330 Euchner - Non-contact safety switches CES-I-AP-.- C04-…, flying lead

Product Details

  • Weight
    1.5652802 lb
  • Series
    CES-AP
  • Product Class
    Safety System
  • Switching hysteresis
    min.1 mm
  • Assured operating distance Sao
    min.6 mm
  • Assured release distance Sar
    max.60 mm
  • Operating distance
    11 mm
  • Performance Level
    PL e
  • Mission time
    20
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • PFHD
    4.1 x 10⁻⁹
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Additional feature
    Rubber support included
  • Output voltage
    0,8 x UB ... UB V DC
  • Repeat accuracy R
    ≤ 10
  • Switching current
    max.50 mA
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Rated conditional short-circuit current
    100 A
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Test-pulse interval
    min.100 ms
  • Turn-on time
    max.300 ms
  • Type of output
    p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Fusing
    0,25 ... 8 A
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Current consumption
    max.35 mA
  • Rated insulation voltage Ui
    300 V
  • Connection
    connection cable PUR, length 20m
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the outputs.)
  • Ready delay
    0,5 s
  • Mounting distance
    min.80 mm
  • Switching frequency
    max.1 Hz
  • Tightening torque
    max.0,8 Nm
  • Installation orientation
    Any
  • Weight
    0,7 kg
  • Mounting method
    Surface mounting on metal
  • Degree of protection
    IP67
  • Static bending radius
    5 x cable diameter
  • Housing material
    Plastic, PBT
  • Material
    NBR 80 ±5 Shore
  • Dynamic bending radius
    10 x cable diameter
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Cable ambient temperature (static)
    -25 ... 65 °C
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 117330 on MQ Automation is $265.97. Order now.


About the product

Safety switch with integrated evaluation electronics;No series connection;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Three active faces;Connecting cable PUR, 20 m, flying lead;Multicode;Monitoring output OD


Manufacturer warranty

117330 Euchner

$265.97

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$265.97

$265.97 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 117330 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Performance Level

Mission time

Category

For the approval acc. to ...

PFHD

Discrepancy time

Off-state current Ir

Additional feature

Output voltage

Repeat accuracy R

Switching current

Test pulses

Rated conditional short-c...

Utilization category acc....

Test-pulse interval

Turn-on time

Type of output

Risk time according to EN...

Safety class

Degree of contamination (...

EMC protection requiremen...

Fusing

Rated impulse withstand v...

Current consumption

Rated insulation voltage ...

Connection

Operating voltage DC

Ready delay

Mounting distance

Switching frequency

Tightening torque

Installation orientation

Mounting method

Degree of protection

Static bending radius

Housing material

Material

Dynamic bending radius

Shock and vibration resis...

Cable ambient temperature...

Cable ambient temperature...

Extension of risk time ac...

Selected product

117330
0 in stock
117330
Euchner

117330 Euchner - Non-contact safety switches CES-I-AP-.- C04-…, flying lead

Weight1.5652802 lb

SeriesCES-AP

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.6 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Performance LevelPL e

Mission time20

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

PFHD4.1 x 10⁻⁹

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Additional featureRubber support included

Output voltage0,8 x UB ... UB V DC

Repeat accuracy R≤ 10

Switching currentmax.50 mA

Test pulsesmax.0,3 ms (Applies for a l...

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.100 ms

Turn-on timemax.300 ms

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Current consumptionmax.35 mA

Rated insulation voltage Ui300 V

Connectionconnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay0,5 s

Mounting distancemin.80 mm

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Degree of protectionIP67

Static bending radius5 x cable diameter

Housing materialPlastic, PBT

MaterialNBR 80 ±5 Shore

Dynamic bending radius10 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Extension of risk time according to EN 60947-5-3 per device-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

Operating distance11 mm

Performance LevelPL e

Mission time20

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

PFHD4.1 x 10⁻⁹

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Additional featureRubber support included

Output voltage0,8 x UB ... UB V DC

Repeat accuracy R≤ 10

Switching currentmax.50 mA

Test pulsesmax.1,0 ms (Applies for a l...

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test-pulse intervalmin.140 ms

Turn-on timemax.400 ms

Type of outputSemiconductor output, p-swit...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Current consumptionmax.35 mA (Without taking i...

Rated insulation voltage Ui300 V

ConnectionConnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay10 s

Mounting distancemin.80 mm

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Degree of protectionIP67

Static bending radius5 x cable diameter

Housing materialPlastic, PBT

MaterialNBR 80 ±5 Shore

Dynamic bending radius10 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Performance LevelPL e

Mission time20

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

PFHD1.8 x 10⁻⁹

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Additional feature-

Output voltage0,8 x UB ... UB V DC

Repeat accuracy R≤ 10

Switching currentmax.50 mA

Test pulsesmax.0,3 ms (Applies for a l...

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.100 ms

Turn-on timemax.300 ms

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Current consumptionmax.30 mA (Without taking i...

Rated insulation voltage Ui75 V

Connectionconnection cable PVC, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay0,5 s

Mounting distancemin.400 mm

Switching frequencymax.1 Hz

Tightening torquemax.1 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Degree of protectionIP67, IP69K

Static bending radius5 x cable diameter

Housing materialPlastic, PBT

Material-

Dynamic bending radius10 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

Extension of risk time according to EN 60947-5-3 per device-

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 117330?
The price of 117330 on MQ Automation is $265.97. Order now.

Out if stock but available for backorder.

117330 Euchner - Non-contact safety switches CES-I-AP-.- C04-…, flying lead

What can I help you find today?

Recommended parts