117312 Euchner Safety Accessories

117312 on MQ Automation
Euchner
  • 117312
  • 117312
  • 117312

Part#:117312

Alt. Part#:MGB-L1-ARA-AB8A1-S1-L-117312

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

117312 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    2.425082 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Performance Level
    PL e
  • PFHD
    3.7 x 10⁻⁹
  • Mission time
    20 y
  • Product version number
    V4.0.0
  • Switching element
    2 pos. driven NC + 1NO
  • Special features
    With auxiliary contact
  • Category
    4
  • Output voltage
    UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Assignment diagram
    L1
  • Output current
    max.50 mA
  • Version
    Emergency stop
  • Power supply LED
    24 V DC
  • Test pulses
    max.5 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Test-pulse interval
    min.100 ms
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 100 mA
  • Switching voltage
    5 ... 24 V
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    30 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Door hinge DIN left
  • Guard locking principle
    Closed-circuit current principle
  • Weight
    0,75 kg
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP65
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Connection
    Plug connector RC18 (X6)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 117312 on MQ Automation is $1,403.15. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode


Manufacturer warranty

117312 Euchner

$1,403.15

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,403.15

$1,403.15 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 117312 with other products

Weight

Series

Product Class

B10D

Performance Level

PFHD

Mission time

Product version number

Switching element

Special features

Category

Output voltage

Assignment diagram

Output current

Version

Power supply LED

Test pulses

Current consumption

Type of output

Operating voltage DC

Test-pulse interval

Breaking capacity

Switching current

Switching voltage

Transponder coding

Risk time according to EN...

Discrepancy time

Safety class

Degree of contamination (...

Rated insulation voltage ...

Rated impulse withstand v...

Utilization category acc....

Locking force FZh

Ambient temperature

Installation orientation

Guard locking principle

Mechanical life

Switching frequency

Degree of protection

Housing material

Connection

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

117312
0 in stock
117312
Euchner

117312 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, em...

Weight2.425082 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Performance LevelPL e

PFHD3.7 x 10⁻⁹

Mission time20 y

Product version numberV4.0.0

Switching element2 pos. driven NC + 1NO

Special featuresWith auxiliary contact

Category4

Output voltageUA-2V ... UA V DC (Value at...

Assignment diagramL1

Output currentmax.50 mA

VersionEmergency stop

Power supply LED24 V DC

Test pulsesmax.5 ms

Current consumptionmax.80 mA ((no load on outp...

Type of outputSemiconductor outputs, p-swi...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Test-pulse intervalmin.100 ms

Breaking capacitymax.0,25 W

Switching current1 ... 100 mA

Switching voltage5 ... 24 V

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui30 V

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh2000 N

Ambient temperature-20 ... 55 °C

Installation orientationDoor hinge DIN left

Guard locking principleClosed-circuit current princ...

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Degree of protectionIP65

Housing materialReinforced plastic; die-cast...

ConnectionPlug connector RC18 (X6)

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Product version number-

Switching element2 pos. driven NC

Special features-

Category4

Output voltage0 ... 1 V DC

Assignment diagram-

Output current-

VersionEmergency stop

Power supply LED-

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Type of output2 semiconductor outputs, p-s...

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.100 ms

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Transponder coding-

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Ambient temperature-20 ... +55 °C

Installation orientationDoor hinge DIN right

Guard locking principle-

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Connection2 plug connectors M12, 5-pin

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Product version number-

Switching element-

Special features-

Category4

Output voltage0,8xUB ... UB V DC

Assignment diagram-

Output current-

Version-

Power supply LED-

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Type of outputp-switching, short circuit-p...

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.140 ms

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Ambient temperature-20 ... +55 °C

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Connection2 plug connectors M12, 5 and...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 117312?
The price of 117312 on MQ Automation is $1,403.15. Order now.

Out if stock but available for backorder.

117312 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

What can I help you find today?

Recommended parts