117310 Euchner Safety Accessories

117310 on MQ Automation
Euchner
  • 117310
  • 117310
  • 117310

Part#:117310

Alt. Part#:MGB-L1-ARA-AB8A1-S1-R-117310

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

117310 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    2.425082 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Performance Level
    PL e
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Product version number
    V4.0.0
  • Category
    4
  • Special features
    With auxiliary contact
  • Switching element
    2 pos. driven NC + 1NO
  • Version
    Emergency stop
  • Breaking capacity
    max.0,25 W
  • Assignment diagram
    L1
  • Switching current
    1 ... 10 mA
  • Current consumption
    max.80 mA ((no load on outputs))
  • Switching voltage
    UA V
  • Power supply LED
    24 V DC
  • Output current
    1 ... 200 mA
  • Degree of protection
    IP65
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Switching frequency
    0,25 Hz
  • Discrepancy time
    max.10 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Guard locking principle
    Closed-circuit current principle
  • Rated insulation voltage Ui
    30 V
  • Installation orientation
    Door hinge DIN right
  • Connection
    Plug connector RC18 (X6)
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    0,75 kg
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Mechanical life
    0,1 x 10⁶
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 117310 on MQ Automation is $1,403.15. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode


Manufacturer warranty

117310 Euchner

$1,403.15

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,403.15

$1,403.15 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 117310 with other products

Weight

Series

Product Class

B10D

Performance Level

Mission time

PFHD

Product version number

Category

Special features

Switching element

Version

Breaking capacity

Assignment diagram

Switching current

Current consumption

Switching voltage

Power supply LED

Output current

Degree of protection

Operating voltage DC

Output voltage

Type of output

Test-pulse interval

Test pulses

Safety class

Degree of contamination (...

Transponder coding

Risk time according to EN...

Switching frequency

Discrepancy time

Rated impulse withstand v...

Guard locking principle

Rated insulation voltage ...

Installation orientation

Connection

Ambient temperature

Utilization category acc....

Locking force FZh

Mechanical life

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

117310
0 in stock
117310
Euchner

117310 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, em...

Weight2.425082 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Performance LevelPL e

Mission time20 y

PFHD3.7 x 10⁻⁹

Product version numberV4.0.0

Category4

Special featuresWith auxiliary contact

Switching element2 pos. driven NC + 1NO

VersionEmergency stop

Breaking capacitymax.0,25 W

Assignment diagramL1

Switching current1 ... 10 mA

Current consumptionmax.80 mA ((no load on outp...

Switching voltageU<sub>A</sub> V

Power supply LED24 V DC

Output current1 ... 200 mA

Degree of protectionIP65

Operating voltage DC24 V DC -15% ... 10% ((Re...

Output voltageUB-2V ... UB V DC (Value at...

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Switching frequency0,25 Hz

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Guard locking principleClosed-circuit current princ...

Rated insulation voltage Ui30 V

Installation orientationDoor hinge DIN right

ConnectionPlug connector RC18 (X6)

Ambient temperature-20 ... 55 °C

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh2000 N

Mechanical life0,1 x 10⁶

Housing materialReinforced plastic; die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Performance LevelPL e

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Product version number-

Category4

Special features-

Switching element2 pos. driven NC

VersionEmergency stop

Breaking capacity-

Assignment diagram-

Switching current1 ... 150 mA

Current consumption40 mA

Switching voltage-

Power supply LED-

Output current-

Degree of protectionIP65 (Screwed tight plug co...

Operating voltage DC24 V DC -15% ... 15% Rev...

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Risk time according to EN 60947-5-3-

Switching frequencymax.0,5 Hz

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Guard locking principle-

Rated insulation voltage Ui50 V

Installation orientationDoor hinge DIN right

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Performance LevelPL e

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Product version number-

Category4

Special features-

Switching element-

Version-

Breaking capacity-

Assignment diagram-

Switching current1 ... 50 mA

Current consumption40 mA

Switching voltage-

Power supply LED-

Output current-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Operating voltage DC24 V DC -15% ... 15% Rev...

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Switching frequencymax.0,5 Hz

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Guard locking principleClosed-circuit current princ...

Rated insulation voltage Ui50 V

Installation orientationAny

Connection2 plug connectors M12, 5 and...

Ambient temperature-20 ... +55 °C

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 117310?
The price of 117310 on MQ Automation is $1,403.15. Order now.

Out if stock but available for backorder.

117310 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

What can I help you find today?

Recommended parts