117026 Euchner Safety Accessories
Part#:117026
Alt. Part#:MGB-L2B-PNC-L-117026
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
117026 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 4 control elements, push-pull plug, RC12
Product Details
- Weight 7.54420964 lb
- Series Spare parts
- Product Class Accessories
- Safety Integrity Level SIL 3 (EN 62061:2005)
- B10D 0,13 x 10⁶
- Mission time 20
- Diagnostic Coverage (DC) 99
- Performance Level PL e
- Category 4
- Product version number V3.30.11
- PFHD 4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
- Switching element 1NO
- Color white
- Special features Printed
- Version Illuminated push buttons
- Assignment diagram B1
- Assured release distance Sar max.65 mm
- Bus data protocol Profinet (IEC 61158 type 10)
- Safety data protocol Profisafe (IEC 61784-3-3)
- Fusing min.1 A Slow blow
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Auxiliary voltage DC 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
- Connecting cable Profinet I/O cable, at least cat. 5e
- Safety class III
- Transponder coding Multicode
- Degree of contamination (external, according to EN 60947-1) 3
- Maximum feed-in current in the connection block max.4000 mA
- EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
- Rated impulse withstand voltage Uimp 0,5 kV
- Locking force FZh 2000 N
- Current consumption max.500 mA
- Rated insulation voltage Ui 75 V
- Guard locking principle Open-circuit current principle
- Connection Push-pull RJ45 (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
- Switching frequency 0,25 Hz
- Reaction time max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
- Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
- Installation orientation Door hinge DIN left
- Ambient temperature -20 ... 55 °C
- Weight 3,1 kg
- Shock and vibration resistance In acc. with EN 60947-5-3
- Mechanical life 0,1 x 10⁶
- Degree of protection IP54
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 117026 on MQ Automation is $3,031.32. Order now.
About the product
Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;3 illuminated pushbuttons with symbol;Push-pull plug;including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Multicode
Manufacturer warranty
117026 Euchner
$3,031.32
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$3,031.32
$3,031.32 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 117026 with other products
Weight
Series
Product Class
Safety Integrity Level
B10D
Mission time
Diagnostic Coverage (DC)
Performance Level
Category
Product version number
PFHD
Switching element
Color
Special features
Version
Assignment diagram
Assured release distance ...
Bus data protocol
Safety data protocol
Fusing
Operating voltage DC
Auxiliary voltage DC
Connecting cable
Safety class
Transponder coding
Degree of contamination (...
Maximum feed-in current i...
EMC protection requiremen...
Rated impulse withstand v...
Locking force FZh
Current consumption
Rated insulation voltage ...
Guard locking principle
Connection
Switching frequency
Reaction time
Housing material
Installation orientation
Ambient temperature
Shock and vibration resis...
Mechanical life
Degree of protection
For the approval acc. to ...
Operating current
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Switching current
Type of output
Turn-on time
Switching load
Output voltage
Connection rating
Utilization category acc....
Overtravel
Test-pulse interval
Extraction force
Test pulses
Actuating force
Approach speed
Ready delay
Additional feature
Risk time according to EN...
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Selected product

117026
Euchner
117026 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) ...
Weight7.54420964 lb
SeriesSpare parts
Product ClassAccessories
Safety Integrity LevelSIL 3 (EN 62061:2005)
B10D0,13 x 10⁶
Mission time20
Diagnostic Coverage (DC)99
Performance LevelPL e
Category4
Product version numberV3.30.11
PFHD4.07 x 10⁻⁸ (Fixed failure ...
Switching element1NO
Colorwhite
Special featuresPrinted
VersionIlluminated push buttons
Assignment diagramB1
Assured release distance Sarmax.65 mm
Bus data protocolProfinet (IEC 61158 type 10)
Safety data protocolProfisafe (IEC 61784-3-3)
Fusingmin.1 A Slow blow
Operating voltage DC24 V DC -15% ... 10% ((Re...
Auxiliary voltage DC24 V DC -15% ... +10% (Th...
Connecting cableProfinet I/O cable, at least...
Safety classIII
Transponder codingMulticode
Degree of contamination (external, according to EN 60947-1)3
Maximum feed-in current in the connection blockmax.4000 mA
EMC protection requirementsIn accordance with EN 61000-...
Rated impulse withstand voltage Uimp0,5 kV
Locking force FZh2000 N
Current consumptionmax.500 mA
Rated insulation voltage Ui75 V
Guard locking principleOpen-circuit current princip...
ConnectionPush-pull RJ45 (X4 (The doc...
Switching frequency0,25 Hz
Reaction timemax.250 ms Switch-off time...
Housing materialReinforced plastic, die-cast...
Installation orientationDoor hinge DIN left
Ambient temperature-20 ... 55 °C
Shock and vibration resistanceIn acc. with EN 60947-5-3
Mechanical life0,1 x 10⁶
Degree of protectionIP54
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Switching current-
Type of output-
Turn-on time-
Switching load-
Output voltage-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Overtravel-
Test-pulse interval-
Extraction force-
Test pulses-
Actuating force-
Approach speed-
Ready delay-
Additional feature-
Risk time according to EN 60947-5-3-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 117026?
The price of 117026 on MQ Automation is $3,031.32. Order now.
Out if stock but available for backorder.
117026 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 4 control elements, push-pull plug, RC12
Similar products from: Safety Accessories
What can I help you find today?