117020 Euchner Safety Accessories

117020 on MQ Automation
Euchner
  • 117020
  • 117020

Part#:117020

Alt. Part#:MGB-L1B-PNC-R-117020

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

117020 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 4 control elements, push-pull plug, RC12

Product Details

  • Weight
    7.71837462 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • B10D
    0,13 x 10⁶
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Product version number
    V3.30.11
  • Performance Level
    PL e
  • Diagnostic Coverage (DC)
    99
  • Category
    4
  • Switching element
    1NO
  • Color
    white
  • Special features
    Printed
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Version
    Illuminated push buttons
  • Assignment diagram
    B1
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Transponder coding
    Multicode
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Safety class
    III
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Mechanical life
    0,1 x 10⁶
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    75 V
  • Weight
    3,1 kg
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP54
  • Installation orientation
    Door hinge DIN right
  • Ambient temperature
    -20 ... 55 °C
  • Locking force FZh
    2000 N
  • Current consumption
    max.500 mA
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Push-pull RJ45 (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 117020 on MQ Automation is $3,031.32. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;3 illuminated pushbuttons with symbol;Push-pull plug;including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Multicode


Manufacturer warranty

117020 Euchner

$3,031.32

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,031.32

$3,031.32 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 117020 with other products

Weight

Series

Product Class

Mission time

Safety Integrity Level

B10D

PFHD

Product version number

Performance Level

Diagnostic Coverage (DC)

Category

Switching element

Color

Special features

Safety data protocol

Version

Assignment diagram

Bus data protocol

Assured release distance ...

Fusing

Auxiliary voltage DC

Degree of contamination (...

Transponder coding

Operating voltage DC

Connecting cable

Safety class

EMC protection requiremen...

Maximum feed-in current i...

Mechanical life

Rated impulse withstand v...

Rated insulation voltage ...

Switching frequency

Degree of protection

Installation orientation

Ambient temperature

Locking force FZh

Current consumption

Reaction time

Shock and vibration resis...

Guard locking principle

Connection

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

117020
0 in stock
117020
Euchner

117020 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) wi...

Weight7.71837462 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

B10D0,13 x 10⁶

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Product version numberV3.30.11

Performance LevelPL e

Diagnostic Coverage (DC)99

Category4

Switching element1NO

Colorwhite

Special featuresPrinted

Safety data protocolProfisafe (IEC 61784-3-3)

VersionIlluminated push buttons

Assignment diagramB1

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Degree of contamination (external, according to EN 60947-1)3

Transponder codingMulticode

Operating voltage DC24 V DC -15% ... 10% ((Re...

Connecting cableProfinet I/O cable, at least...

Safety classIII

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Mechanical life0,1 x 10⁶

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui75 V

Switching frequency0,25 Hz

Degree of protectionIP54

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... 55 °C

Locking force FZh2000 N

Current consumptionmax.500 mA

Reaction timemax.250 ms Switch-off time...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Guard locking principleClosed-circuit current princ...

ConnectionPush-pull RJ45 (X4 (The doc...

Housing materialReinforced plastic, die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Product version number-

Performance LevelPL e

Diagnostic Coverage (DC)-

Category4

Switching element2 pos. driven NC

Color-

Special features-

Safety data protocol-

VersionEmergency stop

Assignment diagram-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Operating voltage DC24 V DC -15% ... 15% Rev...

Connecting cable-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Mechanical life1 x 10⁶

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... +55 °C

Locking force FZh-

Current consumption40 mA

Reaction time-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

B10D-

PFHD4.1 x 10 ⁻⁹

Product version number-

Performance LevelPL e

Diagnostic Coverage (DC)-

Category4

Switching element-

Color-

Special features-

Safety data protocol-

Version-

Assignment diagram-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Operating voltage DC24 V DC -15% ... 15% Rev...

Connecting cable-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Mechanical life1 x 10⁶

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Ambient temperature-20 ... +55 °C

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Current consumption40 mA

Reaction time-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 117020?
The price of 117020 on MQ Automation is $3,031.32. Order now.

Out if stock but available for backorder.

117020 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 4 control elements, push-pull plug, RC12

What can I help you find today?

Recommended parts