121088 Euchner Safety Accessories

121088 on MQ Automation
Euchner
  • 121088
  • 121088
  • 121088

Part#:121088

Alt. Part#:MGB-L1-ARA-AL2A1-M-L-121088

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121088 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier

Product Details

  • Weight
    2.20682462 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    2.8 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Additional feature
    Incl. cover set ID. No. 120344
  • Version
    Illuminated push buttons
  • Product version number
    V4.0.0
  • Assignment diagram
    L1
  • Switching element
    1NO
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Output current
    1 ... 200 mA
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Current consumption
    max.80 mA ((no load on outputs))
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • Connection cross-section
    0,25 ... 0,75 mm²
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Degree of protection
    IP65
  • Installation orientation
    Door hinge DIN left
  • Weight
    0,75 kg
  • Connection
    Cable entries M20x1.5
  • Guard locking principle
    Closed-circuit current principle
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121088 on MQ Automation is $1,184.40. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);2 pushbuttons (illuminated);With lens set, 6 pcs.;incl. adhesive labels;With cable entry;Unicode


Manufacturer warranty

121088 Euchner

$1,184.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,184.40

$1,184.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121088 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Category

Additional feature

Version

Product version number

Assignment diagram

Switching element

Power supply LED

Breaking capacity

Switching current

Switching voltage

Output current

Output voltage

Test-pulse interval

Test pulses

Operating voltage DC

Type of output

Current consumption

Transponder coding

Risk time according to EN...

Discrepancy time

Rated impulse withstand v...

Degree of contamination (...

Safety class

Connection cross-section

Rated insulation voltage ...

Utilization category acc....

Locking force FZh

Ambient temperature

Housing material

Degree of protection

Installation orientation

Connection

Guard locking principle

Mechanical life

Switching frequency

For the approval acc. to ...

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

121088
0 in stock
121088
Euchner

121088 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, in...

Weight2.20682462 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD2.8 x 10⁻⁹

Performance LevelPL e

Category4

Additional featureIncl. cover set ID. No. 1203...

VersionIlluminated push buttons

Product version numberV4.0.0

Assignment diagramL1

Switching element1NO

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Output current1 ... 200 mA

Output voltageUB-2V ... UB V DC (Value at...

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Operating voltage DC24 V DC -15% ... 10% ((Re...

Type of outputSemiconductor outputs, p-swi...

Current consumptionmax.80 mA ((no load on outp...

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Connection cross-section0,25 ... 0,75 mm²

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh2000 N

Ambient temperature-20 ... 55 °C

Housing materialReinforced plastic; die-cast...

Degree of protectionIP65

Installation orientationDoor hinge DIN left

ConnectionCable entries M20x1.5

Guard locking principleClosed-circuit current princ...

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

For the approval acc. to UL the following applies-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Additional featureEscape release actuated by p...

Version-

Product version number-

Assignment diagram-

Switching element-

Power supply LED-

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Output current-

Output voltage0,8xUB ... UB V DC

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Type of outputp-switching, short circuit-p...

Current consumption40 mA

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Connection cross-section-

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Additional feature-

VersionEmergency stop

Product version number-

Assignment diagram-

Switching element2 pos. driven NC

Power supply LED-

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Output current-

Output voltage0 ... 1 V DC

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Type of output2 semiconductor outputs, p-s...

Current consumption40 mA

Transponder coding-

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Connection cross-section-

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121088?
The price of 121088 on MQ Automation is $1,184.40. Order now.

Out if stock but available for backorder.

121088 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier

What can I help you find today?

Recommended parts