121067 Euchner Safety Accessories

121067 on MQ Automation
Euchner
  • 121067
  • 121067
  • 121067

Part#:121067

Alt. Part#:MGB-L1-ARA-AL2A1-M-L-121067

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121067 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton

Product Details

  • Weight
    2.19139228 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Additional feature
    Incl. cover set ID. No. 120344
  • Performance Level
    PL e
  • Switching element
    1NO
  • Category
    4
  • Product version number
    V4.0.0
  • Assignment diagram
    L1
  • Version
    Illuminated push buttons
  • Power supply LED
    24 V DC
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Breaking capacity
    max.0,25 W
  • Output current
    1 ... 200 mA
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Current consumption
    max.375 mA ((With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Transponder coding
    Unicode
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Safety class
    III
  • Discrepancy time
    max.10 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Guard locking principle
    Closed-circuit current principle
  • Locking force FZh
    2000 N
  • Degree of protection
    IP65
  • Switching frequency
    0,25 Hz
  • Installation orientation
    Door hinge DIN left
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Connection
    Cable entries M20x1.5
  • Mechanical life
    0,1 x 10⁶
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121067 on MQ Automation is $1,175.31. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);2 pushbuttons (illuminated);With lens set, 6 pcs.;incl. adhesive labels;With cable entry;Unicode


Manufacturer warranty

121067 Euchner

$1,175.31

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,175.31

$1,175.31 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121067 with other products

Weight

Series

Product Class

Mission time

PFHD

Additional feature

Performance Level

Switching element

Category

Product version number

Assignment diagram

Version

Power supply LED

Switching current

Switching voltage

Breaking capacity

Output current

Output voltage

Type of output

Test-pulse interval

Test pulses

Current consumption

Operating voltage DC

Risk time according to EN...

Transponder coding

Connection cross-section

Safety class

Discrepancy time

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Utilization category acc....

Guard locking principle

Locking force FZh

Degree of protection

Switching frequency

Installation orientation

Housing material

Ambient temperature

Connection

Mechanical life

For the approval acc. to ...

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

121067
0 in stock
121067
Euchner

121067 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton

Weight2.19139228 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Additional featureIncl. cover set ID. No. 1203...

Performance LevelPL e

Switching element1NO

Category4

Product version numberV4.0.0

Assignment diagramL1

VersionIlluminated push buttons

Power supply LED24 V DC

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Breaking capacitymax.0,25 W

Output current1 ... 200 mA

Output voltageUB-2V ... UB V DC (Value at...

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Current consumptionmax.375 mA ((With energized...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Risk time according to EN 60947-5-3max.350 ms

Transponder codingUnicode

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Safety classIII

Discrepancy timemax.10 ms

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Locking force FZh2000 N

Degree of protectionIP65

Switching frequency0,25 Hz

Installation orientationDoor hinge DIN left

Housing materialReinforced plastic; die-cast...

Ambient temperature-20 ... 55 °C

ConnectionCable entries M20x1.5

Mechanical life0,1 x 10⁶

For the approval acc. to UL the following applies-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Additional featureEscape release actuated by p...

Performance LevelPL e

Switching element-

Category4

Product version number-

Assignment diagram-

Version-

Power supply LED-

Switching current1 ... 50 mA

Switching voltage-

Breaking capacity-

Output current-

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3max.260 ms

Transponder coding-

Connection cross-section-

Safety classIII

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching frequencymax.0,5 Hz

Installation orientationAny

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5 and...

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Additional feature-

Performance LevelPL e

Switching element2 pos. driven NC

Category4

Product version number-

Assignment diagram-

VersionEmergency stop

Power supply LED-

Switching current1 ... 150 mA

Switching voltage-

Breaking capacity-

Output current-

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3-

Transponder coding-

Connection cross-section-

Safety classIII

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principle-

Locking force FZh-

Degree of protectionIP65 (Screwed tight plug co...

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5-pin

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121067?
The price of 121067 on MQ Automation is $1,175.31. Order now.

Out if stock but available for backorder.

121067 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton

What can I help you find today?

Recommended parts