121086 Euchner Safety Accessories

121086 on MQ Automation
Euchner
  • 121086
  • 121086
  • 121086

Part#:121086

Alt. Part#:MGB-L1-ARA-AL2A1-M-R-121086

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121086 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier

Product Details

  • Weight
    2.19139228 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V4.0.0
  • Switching element
    1NO
  • Version
    Illuminated push buttons
  • Additional feature
    Incl. cover set ID. No. 120344
  • Assignment diagram
    L1
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Switching voltage
    UA V
  • Switching current
    1 ... 10 mA
  • Output current
    1 ... 200 mA
  • Test-pulse interval
    min.100 ms
  • Output voltage
    0 ... 1 V DC
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test pulses
    max.1 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Discrepancy time
    max.10 ms
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Degree of protection
    IP65
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Connection
    Cable entries M20x1.5
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Ambient temperature
    -20 ... 55 °C
  • Locking force FZh
    2000 N
  • Guard locking principle
    Closed-circuit current principle
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Switching frequency
    0,25 Hz
  • Installation orientation
    Door hinge DIN right
  • Mechanical life
    0,1 x 10⁶
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121086 on MQ Automation is $1,184.40. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);2 pushbuttons (illuminated);With lens set, 6 pcs.;incl. adhesive labels;With cable entry;Unicode


Manufacturer warranty

121086 Euchner

$1,184.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,184.40

$1,184.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121086 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Category

Product version number

Switching element

Version

Additional feature

Assignment diagram

Power supply LED

Breaking capacity

Switching voltage

Switching current

Output current

Test-pulse interval

Output voltage

Type of output

Test pulses

Current consumption

Operating voltage DC

Discrepancy time

Transponder coding

Risk time according to EN...

Degree of contamination (...

Degree of protection

Connection cross-section

Safety class

Rated impulse withstand v...

Connection

Rated insulation voltage ...

Utilization category acc....

Ambient temperature

Locking force FZh

Guard locking principle

Housing material

Switching frequency

Installation orientation

Mechanical life

For the approval acc. to ...

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

121086
0 in stock
121086
Euchner

121086 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, in...

Weight2.19139228 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

Product version numberV4.0.0

Switching element1NO

VersionIlluminated push buttons

Additional featureIncl. cover set ID. No. 1203...

Assignment diagramL1

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Switching voltageU<sub>A</sub> V

Switching current1 ... 10 mA

Output current1 ... 200 mA

Test-pulse intervalmin.100 ms

Output voltage0 ... 1 V DC

Type of outputSemiconductor outputs, p-swi...

Test pulsesmax.1 ms

Current consumptionmax.80 mA ((no load on outp...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Discrepancy timemax.10 ms

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Degree of contamination (external, according to EN 60947-1)3

Degree of protectionIP65

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

ConnectionCable entries M20x1.5

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Ambient temperature-20 ... 55 °C

Locking force FZh2000 N

Guard locking principleClosed-circuit current princ...

Housing materialReinforced plastic; die-cast...

Switching frequency0,25 Hz

Installation orientationDoor hinge DIN right

Mechanical life0,1 x 10⁶

For the approval acc. to UL the following applies-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Switching element-

Version-

Additional featureEscape release actuated by p...

Assignment diagram-

Power supply LED-

Breaking capacity-

Switching voltage-

Switching current1 ... 50 mA

Output current-

Test-pulse intervalmin.140 ms

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Discrepancy timemax.10 ms In acc. with EN ...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Degree of contamination (external, according to EN 60947-1)3

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Connection cross-section-

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Connection2 plug connectors M12, 5 and...

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Ambient temperature-20 ... +55 °C

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

Switching frequencymax.0,5 Hz

Installation orientationAny

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Switching element2 pos. driven NC

VersionEmergency stop

Additional feature-

Assignment diagram-

Power supply LED-

Breaking capacity-

Switching voltage-

Switching current1 ... 150 mA

Output current-

Test-pulse intervalmin.100 ms

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Discrepancy timemax.10 ms In acc. with EN ...

Transponder coding-

Risk time according to EN 60947-5-3-

Degree of contamination (external, according to EN 60947-1)3

Degree of protectionIP65 (Screwed tight plug co...

Connection cross-section-

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Connection2 plug connectors M12, 5-pin

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Ambient temperature-20 ... +55 °C

Locking force FZh-

Guard locking principle-

Housing materialFiber glass reinforced therm...

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121086?
The price of 121086 on MQ Automation is $1,184.40. Order now.

Out if stock but available for backorder.

121086 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier

What can I help you find today?

Recommended parts