114784 Euchner Safety Accessories

114784 on MQ Automation
Euchner
  • 114784
  • 114784
  • 114784

Part#:114784

Alt. Part#:MGB-L1-ARA-AG2A1-M-114784

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

114784 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop

Product Details

  • Weight
    2.26855398 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • Performance Level
    PL e
  • B10D
    0,13 x 10⁶
  • PFHD
    3.7 x 10⁻⁹
  • Product version number
    V4.0.0
  • Category
    4
  • Switching element
    2 pos. driven NC + 1NO
  • Version
    Emergency stop
  • Special features
    With auxiliary contact
  • Assignment diagram
    L1
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Output current
    max.50 mA
  • Switching voltage
    UA V
  • Output voltage
    UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Transponder coding
    Unicode
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Cable entries M20x1.5
  • Degree of protection
    IP65
  • Installation orientation
    Door hinge DIN right
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Locking force FZh
    2000 N
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114784 on MQ Automation is $1,370.26. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, wh, wh);With cable entry;Unicode


Manufacturer warranty

114784 Euchner

$1,370.26

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,370.26

$1,370.26 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 114784 with other products

Weight

Series

Product Class

Mission time

Performance Level

B10D

PFHD

Product version number

Category

Switching element

Version

Special features

Assignment diagram

Test-pulse interval

Test pulses

Current consumption

Operating voltage DC

Power supply LED

Breaking capacity

Switching current

Output current

Switching voltage

Output voltage

Type of output

Risk time according to EN...

Transponder coding

Discrepancy time

Safety class

Connection cross-section

Rated impulse withstand v...

Degree of contamination (...

Rated insulation voltage ...

Utilization category acc....

Housing material

Ambient temperature

Guard locking principle

Connection

Degree of protection

Installation orientation

Mechanical life

Switching frequency

Locking force FZh

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

114784
0 in stock
114784
Euchner

114784 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, e...

Weight2.26855398 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

Performance LevelPL e

B10D0,13 x 10⁶

PFHD3.7 x 10⁻⁹

Product version numberV4.0.0

Category4

Switching element2 pos. driven NC + 1NO

VersionEmergency stop

Special featuresWith auxiliary contact

Assignment diagramL1

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Current consumptionmax.80 mA ((no load on outp...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Output currentmax.50 mA

Switching voltageU<sub>A</sub> V

Output voltageUA-2V ... UA V DC (Value at...

Type of outputSemiconductor outputs, p-swi...

Risk time according to EN 60947-5-3max.350 ms

Transponder codingUnicode

Discrepancy timemax.10 ms

Safety classIII

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Housing materialReinforced plastic; die-cast...

Ambient temperature-20 ... 55 °C

Guard locking principleClosed-circuit current princ...

ConnectionCable entries M20x1.5

Degree of protectionIP65

Installation orientationDoor hinge DIN right

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Locking force FZh2000 N

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Performance LevelPL e

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Product version number-

Category4

Switching element2 pos. driven NC

VersionEmergency stop

Special features-

Assignment diagram-

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Breaking capacity-

Switching current1 ... 150 mA

Output current-

Switching voltage-

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3-

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Connection cross-section-

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Locking force FZh-

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

B10D-

PFHD4.1 x 10 ⁻⁹

Product version number-

Category4

Switching element-

Version-

Special features-

Assignment diagram-

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Breaking capacity-

Switching current1 ... 50 mA

Output current-

Switching voltage-

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Connection cross-section-

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 114784?
The price of 114784 on MQ Automation is $1,370.26. Order now.

Out if stock but available for backorder.

114784 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop

What can I help you find today?

Recommended parts