114712 Euchner Safety Proximity Sensors

114712 on MQ Automation
Euchner
  • 114712
  • 114712
  • 114712

Part#:114712

Alt. Part#:CET4-AR-CDA-CH-50X-SG-114712

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

114712 Euchner - Non-contact safety switch CET-AR-..., M12, with double ramp

Product Details

  • Weight
    2.7116826 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Category
    4
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Switching delay from state change
    max.400 ms
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Output voltage
    0 ... 1 V DC
  • Off-state current Ir
    max.0,25 mA
  • Switching current
    1 ... 200 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Safety class
    III
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    450 mA
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Locking force Fmax
    6500 N
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Switching frequency
    max.0,5 Hz
  • Housing material
    Stainless steel
  • Ready delay
    10 s
  • Weight
    1 kg
  • Degree of freedom X
    ±5 mm
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Any (Preferably head downward)
  • Mechanical life
    1 x 10⁶
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Degree of freedom Z
    ±4 mm
  • Degree of freedom Y
    ±5 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114712 on MQ Automation is $899.66. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Door monitoring output;Indication of the door position by LED;With double ramp;Approach directions A and C (delivery state)


Manufacturer warranty

114712 Euchner

$899.66

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$899.66

$899.66 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 114712 with other products

Weight

Series

Product Class

PFHD

Mission time

Category

Performance Level

For the approval acc. to ...

Switching delay from stat...

Repeat accuracy R

Discrepancy time

Turn-on time

Risk time according to EN...

Output voltage

Off-state current Ir

Switching current

Type of output

Extension of risk time ac...

Switching load

Safety class

Connecting cable

Degree of contamination (...

EMC protection requiremen...

Solenoid duty cycle

Connection rating

Fusing

Solenoid operating voltag...

Utilization category acc....

Current consumption

Locking force FZh

Operating voltage DC

Locking force Fmax

Guard locking principle

Approach speed

Connection

Switching frequency

Housing material

Ready delay

Degree of freedom X

Ambient temperature

Installation orientation

Mechanical life

Degree of protection

Degree of freedom Z

Degree of freedom Y

Shock and vibration resis...

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

114712
0 in stock
114712
Euchner

114712 Euchner - Non-contact safety switch CET-AR-..., M12, with double ramp

Weight2.7116826 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state changemax.400 ms

Repeat accuracy R10 %

Discrepancy timemax.10 ms

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

Output voltage0 ... 1 V DC

Off-state current Irmax.0,25 mA

Switching current1 ... 200 mA

Type of output2 semiconductor outputs, p-s...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (For altern...

Safety classIII

Connecting cable30V DC, 2A (For UL requirem...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating11 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Current consumption450 mA

Locking force FZh5000 N (FZH = FMAX/1.3)

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax6500 N

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Housing materialStainless steel

Ready delay10 s

Degree of freedom X±5 mm

Ambient temperature-20 ... 55 °C

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Degree of protectionIP67 (Screwed tight plug co...

Degree of freedom Z±4 mm

Degree of freedom Y±5 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Output voltage0,8xUB ... UB V DC

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Housing materialDie-cast zinc

Ready delay8 s

Degree of freedom X-

Ambient temperature-20 ... +55 °C

Installation orientationAny

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Degree of freedom Z-

Degree of freedom Y-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Output voltage0 ... 1 V DC

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Extension of risk time according to EN 60947-5-3 per device-

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle-

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Locking force FZh-

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Housing materialFiber glass reinforced therm...

Ready delaymax.1 s

Degree of freedom X-

Ambient temperature-20 ... +55 °C

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Degree of freedom Z-

Degree of freedom Y-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 114712?
The price of 114712 on MQ Automation is $899.66. Order now.

Out if stock but available for backorder.

114712 Euchner - Non-contact safety switch CET-AR-..., M12, with double ramp

What can I help you find today?

Recommended parts