114777 Euchner Safety Locking Systems

114777 on MQ Automation
Euchner

Part#:114777

Alt. Part#:MGB-L2CB-PNC-L-114777

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

114777 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Product Details

  • Weight
    10.0107 lb
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • B10D
    0,13 x 10⁶
  • Diagnostic Coverage (DC)
    99
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Category
    4
  • Performance Level
    PL e
  • Product version number
    V3.30.10
  • Switching element
    1NO
  • Color
    Green
  • Slide-in label
    Inicia estação
  • Version
    Illuminated push buttons
  • Assignment diagram
    L2
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Fusing
    min.1 A Slow blow
  • Assured release distance Sar
    max.65 mm
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Safety class
    III
  • Transponder coding
    Multicode
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Current consumption
    max.500 mA
  • Rated insulation voltage Ui
    75 V
  • Locking force FZh
    2000 N
  • Connection
    Push-pull power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Guard locking principle
    Open-circuit current principle
  • Installation orientation
    Door hinge DIN left
  • Weight
    4,05 kg
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP54
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Reaction time
    max.220 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114777 on MQ Automation is $5,498.78. Order now.


Manufacturer warranty

114777 Euchner

$5,498.78

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$5,498.78

$5,498.78 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 114777 with other products

Weight

Mission time

Safety Integrity Level

B10D

Diagnostic Coverage (DC)

PFHD

Category

Performance Level

Product version number

Switching element

Color

Slide-in label

Version

Assignment diagram

Safety data protocol

Fusing

Assured release distance ...

Bus data protocol

Auxiliary voltage DC

Operating voltage DC

Safety class

Transponder coding

Connecting cable

Degree of contamination (...

EMC protection requiremen...

Maximum feed-in current i...

Rated impulse withstand v...

Current consumption

Rated insulation voltage ...

Locking force FZh

Connection

Guard locking principle

Installation orientation

Ambient temperature

Degree of protection

Mechanical life

Switching frequency

Reaction time

Housing material

Shock and vibration resis...

Series

Product Class

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

114777
0 in stock
114777
Euchner

114777 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Weight10.0107 lb

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

B10D0,13 x 10⁶

Diagnostic Coverage (DC)99

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Category4

Performance LevelPL e

Product version numberV3.30.10

Switching element1NO

ColorGreen

Slide-in labelInicia estação

VersionIlluminated push buttons

Assignment diagramL2

Safety data protocolProfisafe (IEC 61784-3-3)

Fusingmin.1 A Slow blow

Assured release distance Sarmax.65 mm

Bus data protocolProfinet (IEC 61158 type 10)

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Safety classIII

Transponder codingMulticode

Connecting cableProfinet I/O cable, at least...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Rated impulse withstand voltage Uimp0,5 kV

Current consumptionmax.500 mA

Rated insulation voltage Ui75 V

Locking force FZh2000 N

ConnectionPush-pull power (X1 (The do...

Guard locking principleOpen-circuit current princip...

Installation orientationDoor hinge DIN left

Ambient temperature-20 ... 55 °C

Degree of protectionIP54

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Reaction timemax.220 ms Switch-off time...

Housing materialReinforced plastic, die-cast...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Series-

Product Class-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

Mission time20 y

Safety Integrity Level-

B10D0,13 x 10⁶

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

Switching element2 pos. driven NC

Color-

Slide-in label-

VersionEmergency stop

Assignment diagram-

Safety data protocol-

Fusing0,25 ... 8 A

Assured release distance Sar-

Bus data protocol-

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Transponder coding-

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Current consumption40 mA

Rated insulation voltage Ui50 V

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Reaction time-

Housing materialFiber glass reinforced therm...

Shock and vibration resistanceIn acc. with EN 60947-5-3

SeriesMGBS-P-I-AP

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

Mission time20 y

Safety Integrity Level-

B10D-

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

Switching element-

Color-

Slide-in label-

Version-

Assignment diagram-

Safety data protocol-

Fusing0,25 ... 8 A

Assured release distance Sar-

Bus data protocol-

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Transponder coding-

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Current consumption40 mA

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Installation orientationAny

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Reaction time-

Housing materialDie-cast zinc

Shock and vibration resistanceIn acc. with EN 60947-5-3

SeriesCTP-AR

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 114777?
The price of 114777 on MQ Automation is $5,498.78. Order now.

Out if stock but available for backorder.

114777 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

What can I help you find today?

Recommended parts