161577 Euchner Safety Proximity Sensors

161577 on MQ Automation
Euchner
  • 161577
  • 161577
  • 161577

Part#:161577

Alt. Part#:CET4-AP-CRA-AH-50X-SI-C2509-161577

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

7 in stock

Mar 15, 2025

Product description

161577 Euchner - Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems

Product Details

  • Weight
    3.747854 lb
  • Series
    CET-AP
  • Product Class
    Safety System
  • Performance Level
    PL e
  • Mission time
    20 y
  • PFHD
    3.1 x 10⁻⁹
  • Switching delay from state change
    max.700 ms
  • Category
    4
  • Repeat accuracy R
    10 %
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Output voltage
    UB-1,5V ... UB V DC
  • Switching current
    1 ... 200 mA
  • Safety class
    III
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Fusing
    0,25 ... 8 A
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Locking force Fmax
    6500 N
  • Current consumption
    80 mA
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    2 plug connectors M12, 5-pin
  • Locking force FZh
    5000 N
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    1 s
  • Installation orientation
    Any (Preferably head downward)
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    1 kg
  • Degree of freedom Y
    ±5 mm
  • Degree of freedom X
    ±5 mm
  • Degree of freedom Z
    ±4 mm
  • Housing material
    Stainless steel
  • Mechanical life
    1 x 10⁶

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 161577 on MQ Automation is $979.28. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Connection to decentralized peripheral systems (e.g. ET200pro) via Y-distributor;Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Indication of the door position by LED;Wire front release (bowden), 3 m, automatic return;Approach direction A (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

161577 Euchner

$979.28

Your price can be lower.
Log in or Create account to check your discount

Stock:

7

Select Qty:

$979.28

$979.28 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 161577 with other products

Weight

Series

Product Class

Performance Level

Mission time

PFHD

Switching delay from stat...

Category

Repeat accuracy R

Turn-on time

Risk time according to EN...

For the approval acc. to ...

Discrepancy time

Off-state current Ir

Type of output

Output voltage

Switching current

Safety class

Connecting cable

Switching load

Degree of contamination (...

Solenoid duty cycle

Connection rating

EMC protection requiremen...

Solenoid operating voltag...

Fusing

Utilization category acc....

Locking force Fmax

Current consumption

Operating voltage DC

Guard locking principle

Approach speed

Connection

Locking force FZh

Switching frequency

Ready delay

Installation orientation

Degree of protection

Shock and vibration resis...

Ambient temperature

Degree of freedom Y

Degree of freedom X

Degree of freedom Z

Housing material

Mechanical life

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

161577
7 in stock
161577
Euchner

161577 Euchner - Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for co...

Weight3.747854 lb

SeriesCET-AP

Product ClassSafety System

Performance LevelPL e

Mission time20 y

PFHD3.1 x 10⁻⁹

Switching delay from state changemax.700 ms

Category4

Repeat accuracy R10 %

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Output voltageUB-1,5V ... UB V DC

Switching current1 ... 200 mA

Safety classIII

Connecting cable30V DC, 2A (For UL requirem...

Switching load24V DC, class 2 (For altern...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating11 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force Fmax6500 N

Current consumption80 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Locking force FZh5000 N

Switching frequencymax.0,5 Hz

Ready delay1 s

Installation orientationAny (Preferably head downwa...

Degree of protectionIP67 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... 55 °C

Degree of freedom Y±5 mm

Degree of freedom X±5 mm

Degree of freedom Z±4 mm

Housing materialStainless steel

Mechanical life1 x 10⁶

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Performance LevelPL e

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Switching delay from state change-

Category4

Repeat accuracy R10 %

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Type of outputp-switching, short circuit-p...

Output voltage0,8xUB ... UB V DC

Switching current1 ... 50 mA

Safety classIII

Connecting cable-

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating6 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force Fmax3900 N

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of freedom Y-

Degree of freedom X-

Degree of freedom Z-

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Performance LevelPL e

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Switching delay from state change-

Category4

Repeat accuracy R10 %

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Output voltage0 ... 1 V DC

Switching current1 ... 150 mA

Safety classIII

Connecting cable-

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

Connection rating1 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC-

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force Fmax-

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Locking force FZh-

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of freedom Y-

Degree of freedom X-

Degree of freedom Z-

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 161577?
The price of 161577 on MQ Automation is $979.28. Order now.

Out if stock but available for backorder.

161577 Euchner - Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems

What can I help you find today?

Recommended parts