158698 Euchner Safety Locking Systems

158698 on MQ Automation
Euchner
  • 158698
  • 158698

Part#:158698

Alt. Part#:MGB2-L1-MLI-M-Y0000-BJ-158698

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

158698 Euchner - Locking module MGB2-L1-MLI... (module without blanking covers, closed-circuit current principle)

Product Details

  • Weight
    2.6896364 lb
  • Series
    MGB2-MLI
  • Product Class
    Safety System
  • Mission time
    20
  • Diagnostic Coverage (DC)
    99
  • PFHD
    2.62 x 10⁻⁹ (Fixed failure rate without consideration of faults in wearing parts.)
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Performance Level
    PL e
  • Category
    4
  • Operating voltage DC
    24 V DC -25% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Auxiliary voltage DC
    24 V DC -25% ... 15%
  • Transponder coding
    Multicode
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • EMC protection requirements
    EMC directive 2014/30/EU
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    75 V
  • Guard locking principle
    Closed-circuit current principle
  • Switching frequency
    0,25 Hz
  • Current consumption
    max.350 mA
  • Locking force FZh
    2000 N
  • Weight
    1,0 kg
  • Reaction time
    See operating instructions for bus module MBM-...
  • Mechanical life
    0,1 x 10⁶
  • Housing material
    Fiber glass reinforced plastic, die-cast zinc, nickel plated
  • Ambient temperature
    -25 ... 55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of protection
    IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158698 on MQ Automation is $1,007.08. Order now.


About the product

Guard locking for the protection of persons or processes;Locking module MGB2 for connection to a bus module MBM;Interlocking with monitored guard locking;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Adjustable door hinge;Multicode;Compatible with all Modular devices


Manufacturer warranty

158698 Euchner

$1,007.08

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,007.08

$1,007.08 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158698 with other products

Weight

Series

Product Class

Mission time

Diagnostic Coverage (DC)

PFHD

Safety Integrity Level

Performance Level

Category

Operating voltage DC

Auxiliary voltage DC

Transponder coding

Safety class

Rated impulse withstand v...

EMC protection requiremen...

Degree of contamination (...

Rated insulation voltage ...

Guard locking principle

Switching frequency

Current consumption

Locking force FZh

Reaction time

Mechanical life

Housing material

Ambient temperature

Shock and vibration resis...

Degree of protection

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN...

Solenoid duty cycle

Connection rating

Fusing

Solenoid operating voltag...

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Ready delay

Installation orientation

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

158698
0 in stock
158698
Euchner

158698 Euchner - Locking module MGB2-L1-MLI... (module without blanking covers, closed-circuit curre...

Weight2.6896364 lb

SeriesMGB2-MLI

Product ClassSafety System

Mission time20

Diagnostic Coverage (DC)99

PFHD2.62 x 10⁻⁹ (Fixed failure ...

Safety Integrity LevelSIL 3 (EN 62061:2005)

Performance LevelPL e

Category4

Operating voltage DC24 V DC -25% ... 15% ((Re...

Auxiliary voltage DC24 V DC -25% ... 15%

Transponder codingMulticode

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsEMC directive 2014/30/EU

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Guard locking principleClosed-circuit current princ...

Switching frequency0,25 Hz

Current consumptionmax.350 mA

Locking force FZh2000 N

Reaction timeSee operating instructions f...

Mechanical life0,1 x 10⁶

Housing materialFiber glass reinforced plast...

Ambient temperature-25 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP65 (This is the case only...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Ready delay-

Installation orientation-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Safety Integrity Level-

Performance LevelPL e

Category4

Operating voltage DC24 V DC -15% ... 15% Rev...

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Current consumption40 mA

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Reaction time-

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP67/IP69/IP69K (Screwed ti...

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and...

Ready delay8 s

Installation orientationAny

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Mission time20

Diagnostic Coverage (DC)-

PFHD1.9 x 10⁻⁹

Safety Integrity Level-

Performance LevelPL e

Category4

Operating voltage DC24 V DC 15% ... 15% Regu...

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Guard locking principle-

Switching frequencymax.1 Hz

Current consumptionmax.50 mA (Without taking i...

Locking force FZh-

Reaction time-

Mechanical life-

Housing materialPlastic, PBT

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP67

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Switching load-

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle-

Connection rating-

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Actuating force-

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

ConnectionConnection cable PUR, length...

Ready delay10 s

Installation orientationAny

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158698?
The price of 158698 on MQ Automation is $1,007.08. Order now.

Out if stock but available for backorder.

158698 Euchner - Locking module MGB2-L1-MLI... (module without blanking covers, closed-circuit current principle)

What can I help you find today?

Recommended parts