158631 Euchner Safety Proximity Sensors

158631 on MQ Automation
Euchner
  • 158631
  • 158631
  • 158631

Part#:158631

Alt. Part#:CES-I-AP-M-C14-U20-158631

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

158631 Euchner - Non-contact safety switches CES-I-AP-.-C14-…, with cable end sleeves

Product Details

  • Weight
    0.1763696 lb
  • Series
    CES-AP
  • Product Class
    Safety System
  • Assured release distance Sar
    max.72 mm
  • Operating distance
    max.24 mm ALU
  • Assured operating distance Sao
    max.10 mm ALU
  • Mission time
    20
  • PFHD
    4.1 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Repeat accuracy R
    ≤ 10
  • Rated conditional short-circuit current
    100 A
  • Off-state current Ir
    max.0,25 mA
  • Discrepancy time
    max.10 ms
  • Utilization category acc. to EN 60947-5-2
    24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Output voltage
    UB-1,5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
  • Switching current
    1 ... 200 mA
  • Test-pulse interval
    min.140 ms
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Safety class
    III
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.300 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    300 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Current consumption
    max.35 mA (Without taking into account the load currents on the monitoring output and the safety outputs)
  • Fusing
    0,25 ... 8 A
  • Connection
    connection cable PUR, length 20m
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
  • Ready delay
    10 s
  • Switching frequency
    max.1 Hz
  • Tightening torque
    2 Nm
  • Installation orientation
    Any
  • Housing material
    Two-component epoxy resin
  • Mounting distance
    min.80 mm
  • Mounting method
    Surface mounting on metal
  • Degree of protection
    IP65/IP67/IP69/IP69K
  • Weight
    0,7 kg
  • Ambient temperature
    0 ... +65 °C
  • Dynamic bending radius
    10 x cable diameter
  • Static bending radius
    5 x cable diameter
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158631 on MQ Automation is $429.21. Order now.


About the product

Safety switch with integrated evaluation electronics;Safety switch CES-C04 encapsulated in epoxy resin;Tested for material resistance in accordance with Ecolab specifications;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Three active faces;Connecting cable PUR, 20 m, with cable end sleeves;Multicode;Monitoring output OD


Manufacturer warranty

158631 Euchner

$429.21

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$429.21

$429.21 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158631 with other products

Weight

Series

Product Class

Assured release distance ...

Operating distance

Assured operating distanc...

Mission time

PFHD

Performance Level

Category

Repeat accuracy R

Rated conditional short-c...

Off-state current Ir

Discrepancy time

Utilization category acc....

Type of output

Output voltage

Switching current

Test-pulse interval

Test pulses

Safety class

EMC protection requiremen...

Turn-on time

Degree of contamination (...

Rated insulation voltage ...

Rated impulse withstand v...

Current consumption

Fusing

Connection

Operating voltage DC

Ready delay

Switching frequency

Tightening torque

Installation orientation

Housing material

Mounting distance

Mounting method

Degree of protection

Ambient temperature

Dynamic bending radius

Static bending radius

Shock and vibration resis...

Switching hysteresis

For the approval acc. to ...

Additional feature

Risk time according to EN...

Extension of risk time ac...

Cable ambient temperature...

Cable ambient temperature...

Material

Selected product

158631
0 in stock
158631
Euchner

158631 Euchner - Non-contact safety switches CES-I-AP-.-C14-…, with cable end sleeves

Weight0.1763696 lb

SeriesCES-AP

Product ClassSafety System

Assured release distance Sarmax.72 mm

Operating distancemax.24 mm ALU

Assured operating distance Saomax.10 mm ALU

Mission time20

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

Rated conditional short-circuit current100 A

Off-state current Irmax.0,25 mA

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224 V 150 mA (Caution: outpu...

Type of output2 semiconductor outputs, p-s...

Output voltageUB-1,5V ... UB V DC (Values...

Switching current1 ... 200 mA

Test-pulse intervalmin.140 ms

Test pulsesmax.0,3 ms (Applies for a l...

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Turn-on timemax.300 ms

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Current consumptionmax.35 mA (Without taking i...

Fusing0,25 ... 8 A

Connectionconnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay10 s

Switching frequencymax.1 Hz

Tightening torque2 Nm

Installation orientationAny

Housing materialTwo-component epoxy resin

Mounting distancemin.80 mm

Mounting methodSurface mounting on metal

Degree of protectionIP65/IP67/IP69/IP69K

Ambient temperature0 ... +65 °C

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresis-

For the approval acc. to UL the following applies-

Additional feature-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Material-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Assured release distance Sarmax.60 mm

Operating distance11 mm

Assured operating distance Sao6

Mission time20

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

Rated conditional short-circuit current100 A

Off-state current Irmax.0,25 mA

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Type of outputSemiconductor output, p-swit...

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Current consumptionmax.35 mA (Without taking i...

Fusing0,25 ... 8 A

ConnectionConnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay10 s

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Installation orientationAny

Housing materialPlastic, PBT

Mounting distancemin.80 mm

Mounting methodSurface mounting on metal

Degree of protectionIP67

Ambient temperature-

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresismin.1 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

MaterialNBR 80 ±5 Shore

109052
68 in stock
109052
Euchner

109052 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Weight1.763696 lb

SeriesCES-AR

Product ClassSafety System

Assured release distance Sarmax.40 mm

Operating distance15 mm

Assured operating distance Saomin.10 mm

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Category4

Repeat accuracy R≤ 10

Rated conditional short-circuit current100 A

Off-state current Irmax.0,25 mA

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Type of outputp-switching, short circuit-p...

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Test-pulse intervalmin.140 ms

Test pulsesmax.1 ms (Applies for a loa...

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Current consumptionmax.50 mA (Without taking i...

Fusing0,25 ... 8 A

Connectionconnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay10 s

Switching frequencymax.1 Hz

Tightening torquemax.1 Nm

Installation orientationAny

Housing materialPlastic, PBT

Mounting distancemin.120 mm

Mounting methodSurface mounting on metal

Degree of protectionIP67, IP69K

Ambient temperature-

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching hysteresismin.1 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Cable ambient temperature (static)-30 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Material-

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158631?
The price of 158631 on MQ Automation is $429.21. Order now.

Out if stock but available for backorder.

158631 Euchner - Non-contact safety switches CES-I-AP-.-C14-…, with cable end sleeves

What can I help you find today?

Recommended parts