158119 Euchner Safety Accessories

158119 on MQ Automation
Euchner
  • 158119
  • 158119
  • 158119

Part#:158119

Alt. Part#:MGB-L1-APA-AP4A1-S1-L-158119

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

158119 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18

Product Details

  • Weight
    2.3589434 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Version
    Emergency stop
  • Category
    4
  • B10D
    0,13 x 10⁶
  • Product version number
    V4.0.0
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    2 pos. driven NC
  • Assignment diagram
    L1
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Test pulses
    max.0,3 ms
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Power supply LED
    24 V DC
  • Current consumption
    max.80 mA ((no load on outputs))
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Safety class
    III
  • Rated insulation voltage Ui
    30 V
  • Mechanical life
    0,1 x 10⁶
  • Locking force FZh
    2000 N
  • Degree of protection
    IP65
  • Installation orientation
    Door hinge DIN left
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Plug connector RC18 (X6)
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Weight
    0,75 kg
  • Switching frequency
    0,25 Hz
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158119 on MQ Automation is $1,590.09. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;3 pushbuttons (illuminated);With lens set, 6 pcs.;With plug connector RC18;Unicode


Manufacturer warranty

158119 Euchner

$1,590.09

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,590.09

$1,590.09 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158119 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Version

Category

B10D

Product version number

Additional feature

Switching element

Assignment diagram

Output current

Type of output

Test-pulse interval

Output voltage

Test pulses

Operating voltage DC

Power supply LED

Current consumption

Breaking capacity

Switching current

Switching voltage

Degree of contamination (...

Transponder coding

Risk time according to EN...

Discrepancy time

Utilization category acc....

Rated impulse withstand v...

Safety class

Rated insulation voltage ...

Mechanical life

Locking force FZh

Degree of protection

Installation orientation

Guard locking principle

Connection

Housing material

Switching frequency

Ambient temperature

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

158119
0 in stock
158119
Euchner

158119 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, em...

Weight2.3589434 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

VersionEmergency stop

Category4

B10D0,13 x 10⁶

Product version numberV4.0.0

Additional featureIncl. cover set ID. No. 1203...

Switching element2 pos. driven NC

Assignment diagramL1

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Output voltageUB-2V ... UB V DC (Value at...

Test pulsesmax.0,3 ms

Operating voltage DC24 V DC -15% ... 10% ((Re...

Power supply LED24 V DC

Current consumptionmax.80 mA ((no load on outp...

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Degree of contamination (external, according to EN 60947-1)3

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Rated insulation voltage Ui30 V

Mechanical life0,1 x 10⁶

Locking force FZh2000 N

Degree of protectionIP65

Installation orientationDoor hinge DIN left

Guard locking principleClosed-circuit current princ...

ConnectionPlug connector RC18 (X6)

Housing materialReinforced plastic; die-cast...

Switching frequency0,25 Hz

Ambient temperature-20 ... 55 °C

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

VersionEmergency stop

Category4

B10D0,13 x 10⁶

Product version number-

Additional feature-

Switching element2 pos. driven NC

Assignment diagram-

Output current-

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Output voltage0 ... 1 V DC

Test pulsesmax.0,3 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Current consumption40 mA

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Locking force FZh-

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Version-

Category4

B10D-

Product version number-

Additional featureEscape release actuated by p...

Switching element-

Assignment diagram-

Output current-

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Output voltage0,8xUB ... UB V DC

Test pulsesmax.1,0 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Current consumption40 mA

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158119?
The price of 158119 on MQ Automation is $1,590.09. Order now.

Out if stock but available for backorder.

158119 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18

What can I help you find today?

Recommended parts