158117 Euchner - Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18

Product Details

  • Weight
    2.4471282 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Category
    4
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Additional feature
    Incl. cover set ID. No. 120344
  • Mission time
    20 y
  • Switching element
    2 pos. driven NC
  • Product version number
    V4.0.0
  • Version
    Emergency stop
  • Output current
    1 ... 200 mA
  • Assignment diagram
    L1
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Current consumption
    max.375 mA ((With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Power supply LED
    24 V DC
  • Switching voltage
    UA V
  • Test-pulse interval
    min.100 ms
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Test pulses
    max.5 ms
  • Safety class
    III
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Locking force FZh
    2000 N
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Discrepancy time
    max.10 ms
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP65
  • Ambient temperature
    -20 ... 55 °C
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Plug connector RC18 (X6)
  • Weight
    0,75 kg
  • Installation orientation
    Door hinge DIN right

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158117 on MQ Automation is $1,590.09. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;3 pushbuttons (illuminated);With lens set, 6 pcs.;With plug connector RC18;Unicode


Manufacturer warranty

158117 Euchner

$1,590.09

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,590.09

$1,590.09 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158117 with other products

Weight

Series

Product Class

B10D

Category

PFHD

Performance Level

Additional feature

Mission time

Switching element

Product version number

Version

Output current

Assignment diagram

Type of output

Current consumption

Output voltage

Operating voltage DC

Power supply LED

Switching voltage

Test-pulse interval

Breaking capacity

Switching current

Test pulses

Safety class

Transponder coding

Risk time according to EN...

Locking force FZh

Rated impulse withstand v...

Discrepancy time

Utilization category acc....

Rated insulation voltage ...

Degree of contamination (...

Housing material

Mechanical life

Switching frequency

Degree of protection

Ambient temperature

Guard locking principle

Connection

Installation orientation

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

158117
0 in stock
158117
Euchner

158117 Euchner - Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, eme...

Weight2.4471282 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Category4

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Additional featureIncl. cover set ID. No. 1203...

Mission time20 y

Switching element2 pos. driven NC

Product version numberV4.0.0

VersionEmergency stop

Output current1 ... 200 mA

Assignment diagramL1

Type of outputSemiconductor outputs, p-swi...

Current consumptionmax.375 mA ((With energized...

Output voltageUB-2V ... UB V DC (Value at...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Power supply LED24 V DC

Switching voltageU<sub>A</sub> V

Test-pulse intervalmin.100 ms

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Test pulsesmax.5 ms

Safety classIII

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Locking force FZh2000 N

Rated impulse withstand voltage Uimp1,5 kV

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Degree of contamination (external, according to EN 60947-1)3

Housing materialReinforced plastic; die-cast...

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Degree of protectionIP65

Ambient temperature-20 ... 55 °C

Guard locking principleClosed-circuit current princ...

ConnectionPlug connector RC18 (X6)

Installation orientationDoor hinge DIN right

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Additional feature-

Mission time20 y

Switching element2 pos. driven NC

Product version number-

VersionEmergency stop

Output current-

Assignment diagram-

Type of output2 semiconductor outputs, p-s...

Current consumption40 mA

Output voltage0 ... 1 V DC

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Switching voltage-

Test-pulse intervalmin.100 ms

Breaking capacity-

Switching current1 ... 150 mA

Test pulsesmax.0,3 ms (Applies for a l...

Safety classIII

Transponder coding-

Risk time according to EN 60947-5-3-

Locking force FZh-

Rated impulse withstand voltage Uimp0,5 kV

Discrepancy timemax.10 ms In acc. with EN ...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Degree of contamination (external, according to EN 60947-1)3

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Installation orientationDoor hinge DIN right

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Additional featureEscape release actuated by p...

Mission time20 y

Switching element-

Product version number-

Version-

Output current-

Assignment diagram-

Type of outputp-switching, short circuit-p...

Current consumption40 mA

Output voltage0,8xUB ... UB V DC

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Switching voltage-

Test-pulse intervalmin.140 ms

Breaking capacity-

Switching current1 ... 50 mA

Test pulsesmax.1,0 ms (Applies for a l...

Safety classIII

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated impulse withstand voltage Uimp0,5 kV

Discrepancy timemax.10 ms In acc. with EN ...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Degree of contamination (external, according to EN 60947-1)3

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Installation orientationAny

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158117?
The price of 158117 on MQ Automation is $1,590.09. Order now.

Out if stock but available for backorder.

158117 Euchner - Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18

What can I help you find today?

Recommended parts