137736 Euchner Safety Accessories

137736 on MQ Automation
Euchner
  • 137736
  • 137736
  • 137736

Part#:137736

Alt. Part#:MSM-1-K-CA-CPJ-B4-137736

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Only 5 left in stock. Order Now!

Mar 15, 2025

Product description

137736 Euchner - Submodule MSM-1-K... (emergency stop, 1 illuminated pushbutton, 1 key-operated rotary switch, form L)

Product Details

  • Weight
    0.330693 lb
  • Series
    MSM-K
  • Product Class
    Accessories
  • Version
    Emergency stop
  • Switching element
    2 pos. driven NC + 1NO
  • B10D
    0,13 x 10⁶
  • Breaking capacity
    max.0,25 W
  • Power supply LED
    24 V DC
  • Additional feature
    Incl. cover set ID. No. 120344
  • Degree of protection
    IP 65 (IP 20) (IP 65: Only in the screwed tight state with the specified base modules.)
  • Switching current
    5 ... 10 mA
  • Weight
    0,1 kg
  • Ambient temperature
    -25 ... 55 °C
  • Material
    Glass fiber reinforced plastic, die-cast zinc, nickel-plated
  • Installation orientation
    Any
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Current consumption
    max.16 mA
  • Switching voltage
    24 V

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 137736 on MQ Automation is $443.65. Order now.


About the product

Function expansion;Connection type: K;Emergency stop according to ISO 13850;1 illuminated pushbuttons;1 key-operated rotary switch 1 x 90°, form L;incl. lens set


This item can ship in 3-5 days!

Manufacturer warranty

137736 Euchner

$443.65

Your price can be lower.
Log in or Create account to check your discount

Stock:

5

Select Qty:

$443.65

$443.65 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 137736 with other products

Weight

Series

Product Class

Version

Switching element

B10D

Breaking capacity

Power supply LED

Additional feature

Degree of protection

Switching current

Ambient temperature

Material

Installation orientation

Shock and vibration resis...

Current consumption

Switching voltage

Mission time

PFHD

Performance Level

Category

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Type of output

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Output voltage

Degree of contamination (...

Rated insulation voltage ...

Rated impulse withstand v...

Connection rating

Utilization category acc....

Fusing

Operating voltage DC

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Mechanical life

Housing material

Approach speed

Switching frequency

Ready delay

Connection

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Locking force FZh

Guard locking principle

Selected product

137736
5 in stock
137736
Euchner

137736 Euchner - Submodule MSM-1-K... (emergency stop, 1 illuminated pushbutton, 1 key-operated rota...

Weight0.330693 lb

SeriesMSM-K

Product ClassAccessories

VersionEmergency stop

Switching element2 pos. driven NC + 1NO

B10D0,13 x 10⁶

Breaking capacitymax.0,25 W

Power supply LED24 V DC

Additional featureIncl. cover set ID. No. 1203...

Degree of protectionIP 65 (IP 20) (IP 65: Only ...

Switching current5 ... 10 mA

Ambient temperature-25 ... 55 °C

MaterialGlass fiber reinforced plast...

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumptionmax.16 mA

Switching voltage24 V

Mission time-

PFHD-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Type of output-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Mechanical life-

Housing material-

Approach speed-

Switching frequency-

Ready delay-

Connection-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

VersionEmergency stop

Switching element2 pos. driven NC

B10D0,13 x 10⁶

Breaking capacity-

Power supply LED-

Additional feature-

Degree of protectionIP65 (Screwed tight plug co...

Switching current1 ... 150 mA

Ambient temperature-20 ... +55 °C

Material-

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumption40 mA

Switching voltage-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Type of output2 semiconductor outputs, p-s...

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Connection2 plug connectors M12, 5-pin

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Version-

Switching element-

B10D-

Breaking capacity-

Power supply LED-

Additional featureEscape release actuated by p...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching current1 ... 50 mA

Ambient temperature-20 ... +55 °C

Material-

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumption40 mA

Switching voltage-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Type of outputp-switching, short circuit-p...

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Output voltage0,8xUB ... UB V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delay8 s

Connection2 plug connectors M12, 5 and...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 137736?
The price of 137736 on MQ Automation is $443.65. Order now.

Out if stock but available for backorder.

137736 Euchner - Submodule MSM-1-K... (emergency stop, 1 illuminated pushbutton, 1 key-operated rotary switch, form L)

What can I help you find today?