137740 Euchner Safety Accessories
Part#:137740
Alt. Part#:MSM-1-P-CA-P0P-B6-137740
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Mar 16, 2025
Product description
137740 Euchner - Submodule MSM-1-P... (2 illuminated pushbuttons, top/bottom)
Product Details
- Weight 0.31746528 lb
- Series MSM-P
- Product Class Accessories
- Additional feature Incl. cover set ID. No. 120344
- Switching element 1NO
- Version Illuminated push buttons
- Software ID (SW-ID) 137740
- Power supply LED 24 V DC
- Breaking capacity max.0,25 W
- Degree of protection IP 65 (IP 20) (IP 65: Only in the screwed tight state with the specified base modules.)
- Switching current 5 ... 10 mA
- Current consumption max.20 mA
- Shock and vibration resistance In acc. with EN 60947-5-3
- Material Fiber glass reinforced plastic
- Switching voltage 24 V
- Ambient temperature -25 ... 55 °C
- Weight 0,1 kg
- Installation orientation Any
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 137740 on MQ Automation is $233.01. Order now.
About the product
Function expansion for modules MGB2 and MCM;Connection type: P;2 illuminated pushbuttons;incl. lens set
This item can ship in 3-5 days!
Manufacturer warranty
137740 Euchner
$233.01
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$233.01
$233.01 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 137740 with other products
Weight
Series
Product Class
Additional feature
Switching element
Version
Software ID (SW-ID)
Power supply LED
Breaking capacity
Degree of protection
Switching current
Current consumption
Shock and vibration resis...
Material
Switching voltage
Ambient temperature
Installation orientation
Mission time
PFHD
Category
Performance Level
For the approval acc. to ...
Repeat accuracy R
Discrepancy time
Output voltage
Turn-on time
Off-state current Ir
Type of output
Switching load
Risk time according to EN...
Safety class
Degree of contamination (...
Solenoid duty cycle
EMC protection requiremen...
Rated impulse withstand v...
Rated insulation voltage ...
Connection rating
Fusing
Solenoid operating voltag...
Operating voltage DC
Utilization category acc....
Test pulses
Test-pulse interval
Actuating force
Extension of risk time ac...
Extraction force
Overtravel
Locking force Fmax
Approach speed
Retention force
Connection
Locking force FZh
Guard locking principle
Mechanical life
Switching frequency
Ready delay
Housing material
Assured operating distanc...
Switching hysteresis
Assured release distance ...
Operating distance
Rated conditional short-c...
Tightening torque
Mounting method
Mounting distance
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Static bending radius
Selected product

137740
Euchner
137740 Euchner - Submodule MSM-1-P... (2 illuminated pushbuttons, top/bottom)
Weight0.31746528 lb
SeriesMSM-P
Product ClassAccessories
Additional featureIncl. cover set ID. No. 1203...
Switching element1NO
VersionIlluminated push buttons
Software ID (SW-ID)137740
Power supply LED24 V DC
Breaking capacitymax.0,25 W
Degree of protectionIP 65 (IP 20) (IP 65: Only ...
Switching current5 ... 10 mA
Current consumptionmax.20 mA
Shock and vibration resistanceIn acc. with EN 60947-5-3
MaterialFiber glass reinforced plast...
Switching voltage24 V
Ambient temperature-25 ... 55 °C
Installation orientationAny
Mission time-
PFHD-
Category-
Performance Level-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Output voltage-
Turn-on time-
Off-state current Ir-
Type of output-
Switching load-
Risk time according to EN 60947-5-3-
Safety class-
Degree of contamination (external, according to EN 60947-1)-
Solenoid duty cycle-
EMC protection requirements-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Connection rating-
Fusing-
Solenoid operating voltage DC-
Operating voltage DC-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Test-pulse interval-
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connection-
Locking force FZh-
Guard locking principle-
Mechanical life-
Switching frequency-
Ready delay-
Housing material-
Assured operating distance Sao-
Switching hysteresis-
Assured release distance Sar-
Operating distance-
Rated conditional short-circuit current-
Tightening torque-
Mounting method-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-

122813
Euchner
122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release
Weight1.763696 lb
SeriesCTP-AR
Product ClassSafety System
Additional featureEscape release actuated by p...
Switching element-
Version-
Software ID (SW-ID)-
Power supply LED-
Breaking capacity-
Degree of protectionIP67/IP69/IP69K (Screwed ti...
Switching current1 ... 50 mA
Current consumption40 mA
Shock and vibration resistanceIn acc. with EN 60947-5-3
Material-
Switching voltage-
Ambient temperature-20 ... +55 °C
Installation orientationAny
Mission time20 y
PFHD4.1 x 10 ⁻⁹
Category4
Performance LevelPL e
For the approval acc. to UL the following appliesOperation only with UL class...
Repeat accuracy R10 %
Discrepancy timemax.10 ms In acc. with EN ...
Output voltage0,8xUB ... UB V DC
Turn-on timemax.400 ms
Off-state current Irmax.0,25 mA
Type of outputp-switching, short circuit-p...
Switching load24V DC, class 2 (Alternativ...
Risk time according to EN 60947-5-3max.260 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Solenoid duty cycle100 %
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Rated impulse withstand voltage Uimp0,5 kV
Rated insulation voltage Ui50 V
Connection rating6 W
Fusing0,25 ... 8 A
Solenoid operating voltage DC24 V DC -15% ... +10% Re...
Operating voltage DC24 V DC -15% ... 15% Rev...
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Test pulsesmax.1,0 ms (Applies for a l...
Test-pulse intervalmin.140 ms
Actuating force10 N
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Extraction force20 N
Overtravel5 mm
Locking force Fmax3900 N
Approach speedmax.20 m/min
Retention force20 N
Connection2 plug connectors M12, 5 and...
Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...
Guard locking principleClosed-circuit current princ...
Mechanical life1 x 10⁶
Switching frequencymax.0,5 Hz
Ready delay8 s
Housing materialDie-cast zinc
Assured operating distance Sao-
Switching hysteresis-
Assured release distance Sar-
Operating distance-
Rated conditional short-circuit current-
Tightening torque-
Mounting method-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-
Weight0.23589434 lb
SeriesCES-AR
Product ClassSafety System
Additional featureRubber support included
Switching element-
Version-
Software ID (SW-ID)-
Power supply LED-
Breaking capacity-
Degree of protectionIP67
Switching currentmax.50 mA
Current consumptionmax.35 mA (Without taking i...
Shock and vibration resistanceIn acc. with EN 60947-5-3
MaterialNBR 80 ±5 Shore
Switching voltage-
Ambient temperature-
Installation orientationAny
Mission time20
PFHD4.1 x 10⁻⁹
Category4
Performance LevelPL e
For the approval acc. to UL the following appliesOperation only with UL class...
Repeat accuracy R≤ 10
Discrepancy timemax.10 ms
Output voltage0,8 x UB ... UB V DC
Turn-on timemax.400 ms
Off-state current Irmax.0,25 mA
Type of outputSemiconductor output, p-swit...
Switching load-
Risk time according to EN 60947-5-3max.260 ms
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Solenoid duty cycle-
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Rated impulse withstand voltage Uimp1,5 kV
Rated insulation voltage Ui300 V
Connection rating-
Fusing0,25 ... 8 A
Solenoid operating voltage DC-
Operating voltage DC24 V DC 15% ... 15% Regu...
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Test pulsesmax.1,0 ms (Applies for a l...
Test-pulse intervalmin.140 ms
Actuating force-
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
ConnectionConnection cable PUR, length...
Locking force FZh-
Guard locking principle-
Mechanical life-
Switching frequencymax.1 Hz
Ready delay10 s
Housing materialPlastic, PBT
Assured operating distance Sao6
Switching hysteresismin.1 mm
Assured release distance Sarmax.60 mm
Operating distance11 mm
Rated conditional short-circuit current100 A
Tightening torquemax.0,8 Nm
Mounting methodSurface mounting on metal
Mounting distancemin.80 mm
Cable ambient temperature (static)-25 ... 65 °C
Cable ambient temperature (dynamic)-25 ... 65 °C
Dynamic bending radius10 x cable diameter
Static bending radius5 x cable diameter

137740
Euchner
137740 Euchner - Submodule MSM-1-P... (2 illuminated pushbuttons, top/bottom)
Weight0.31746528 lb
SeriesMSM-P
Product ClassAccessories
Additional featureIncl. cover set ID. No. 1203...
Switching element1NO
VersionIlluminated push buttons
Software ID (SW-ID)137740
Power supply LED24 V DC
Breaking capacitymax.0,25 W
Degree of protectionIP 65 (IP 20) (IP 65: Only ...
Switching current5 ... 10 mA
Current consumptionmax.20 mA
Shock and vibration resistanceIn acc. with EN 60947-5-3
MaterialFiber glass reinforced plast...
Switching voltage24 V
Ambient temperature-25 ... 55 °C
Installation orientationAny
Mission time-
PFHD-
Category-
Performance Level-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Output voltage-
Turn-on time-
Off-state current Ir-
Type of output-
Switching load-
Risk time according to EN 60947-5-3-
Safety class-
Degree of contamination (external, according to EN 60947-1)-
Solenoid duty cycle-
EMC protection requirements-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Connection rating-
Fusing-
Solenoid operating voltage DC-
Operating voltage DC-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Test-pulse interval-
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connection-
Locking force FZh-
Guard locking principle-
Mechanical life-
Switching frequency-
Ready delay-
Housing material-
Assured operating distance Sao-
Switching hysteresis-
Assured release distance Sar-
Operating distance-
Rated conditional short-circuit current-
Tightening torque-
Mounting method-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 137740?
The price of 137740 on MQ Automation is $233.01. Order now.
Out if stock but available for backorder.
137740 Euchner - Submodule MSM-1-P... (2 illuminated pushbuttons, top/bottom)
Similar products from: Safety Accessories
What can I help you find today?