128326 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop

Product Details

  • Weight
    2.20462 lb
  • Series
    MGB-EI
  • Product Class
    Accessories
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • B10D
    0,13 x 10⁶
  • Performance Level
    PL e
  • Diagnostic Coverage (DC)
    99
  • PFHD
    3.37 x 10⁻⁹ (Fixed failure rate without consideration of faults in wearing parts.)
  • Category
    4
  • Product version number
    V1.2
  • Additional feature
    Incl. cover set ID. No. 120344
  • Assignment diagram
    L1
  • Switching element
    2 pos. driven NC
  • Version
    Emergency stop illuminated
  • Safety data protocol
    CIP Safety
  • Special features
    With adhesive ring
  • Assured release distance Sar
    max.65 mm
  • Bus data protocol
    Ethernet/IP
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Rated insulation voltage Ui
    75 V
  • Connecting cable
    Ethernet/IP cable, Cat. 5e min.
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Transponder coding
    Unicode
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Current consumption
    max.500 mA
  • Weight
    3,1 kg
  • Degree of protection
    IP54
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Mechanical life
    0,1 x 10⁶
  • Guard locking principle
    Closed-circuit current principle
  • Locking force FZh
    2000 N
  • Connection
    M12 D-coded, screened (X4)
  • Reaction time
    max.100 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Installation orientation
    Door hinge DIN left
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Switching frequency
    0,25 Hz

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 128326 on MQ Automation is $3,137.56. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;3 illuminated pushbuttons;including adhesive labels;Connection via M12 plug;Pre-assembled on mounting plates;Unicode


Manufacturer warranty

128326 Euchner

$3,137.56

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,137.56

$3,137.56 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 128326 with other products

Weight

Series

Product Class

Mission time

Safety Integrity Level

B10D

Performance Level

Diagnostic Coverage (DC)

PFHD

Category

Product version number

Additional feature

Assignment diagram

Switching element

Version

Safety data protocol

Special features

Assured release distance ...

Bus data protocol

Fusing

Auxiliary voltage DC

Rated insulation voltage ...

Connecting cable

Operating voltage DC

Safety class

Degree of contamination (...

Transponder coding

EMC protection requiremen...

Rated impulse withstand v...

Maximum feed-in current i...

Current consumption

Degree of protection

Ambient temperature

Housing material

Mechanical life

Guard locking principle

Locking force FZh

Connection

Reaction time

Installation orientation

Shock and vibration resis...

Switching frequency

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

128326
0 in stock
128326
Euchner

128326 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, eme...

Weight2.20462 lb

SeriesMGB-EI

Product ClassAccessories

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

B10D0,13 x 10⁶

Performance LevelPL e

Diagnostic Coverage (DC)99

PFHD3.37 x 10⁻⁹ (Fixed failure ...

Category4

Product version numberV1.2

Additional featureIncl. cover set ID. No. 1203...

Assignment diagramL1

Switching element2 pos. driven NC

VersionEmergency stop illuminated

Safety data protocolCIP Safety

Special featuresWith adhesive ring

Assured release distance Sarmax.65 mm

Bus data protocolEthernet/IP

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Rated insulation voltage Ui75 V

Connecting cableEthernet/IP cable, Cat. 5e m...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Transponder codingUnicode

EMC protection requirementsIn accordance with EN 61000-...

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection blockmax.4000 mA

Current consumptionmax.500 mA

Degree of protectionIP54

Ambient temperature-20 ... 55 °C

Housing materialReinforced plastic, die-cast...

Mechanical life0,1 x 10⁶

Guard locking principleClosed-circuit current princ...

Locking force FZh2000 N

ConnectionM12 D-coded, screened (X4)

Reaction timemax.100 ms Switch-off time...

Installation orientationDoor hinge DIN left

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequency0,25 Hz

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

B10D0,13 x 10⁶

Performance LevelPL e

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Category4

Product version number-

Additional feature-

Assignment diagram-

Switching element2 pos. driven NC

VersionEmergency stop

Safety data protocol-

Special features-

Assured release distance Sar-

Bus data protocol-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Rated insulation voltage Ui50 V

Connecting cable-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection block-

Current consumption40 mA

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Guard locking principle-

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Reaction time-

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

B10D-

Performance LevelPL e

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Category4

Product version number-

Additional featureEscape release actuated by p...

Assignment diagram-

Switching element-

Version-

Safety data protocol-

Special features-

Assured release distance Sar-

Bus data protocol-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Rated insulation voltage Ui50 V

Connecting cable-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection block-

Current consumption40 mA

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Guard locking principleClosed-circuit current princ...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Reaction time-

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 128326?
The price of 128326 on MQ Automation is $3,137.56. Order now.

Out if stock but available for backorder.

128326 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop

What can I help you find today?

Recommended parts