128323 Euchner Safety Accessories

128323 on MQ Automation
Euchner
  • 128323
  • 128323
  • 128323

Part#:128323

Alt. Part#:MGB-L1B-EIA-R-128323

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

128323 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop

Product Details

  • Weight
    8.19677716 lb
  • Series
    MGB-EI
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Diagnostic Coverage (DC)
    99
  • PFHD
    3.37 x 10⁻⁹ (Fixed failure rate without consideration of faults in wearing parts.)
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V1.2
  • Special features
    With adhesive ring
  • Version
    Emergency stop illuminated
  • Switching element
    2 pos. driven NC
  • Additional feature
    Incl. cover set ID. No. 120344
  • Assignment diagram
    B1
  • Safety data protocol
    CIP Safety
  • Bus data protocol
    Ethernet/IP
  • Assured release distance Sar
    max.65 mm
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Fusing
    min.1 A Slow blow
  • Transponder coding
    Unicode
  • Safety class
    III
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Connecting cable
    Ethernet/IP cable, Cat. 5e min.
  • Locking force FZh
    2000 N
  • Rated insulation voltage Ui
    75 V
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Current consumption
    max.500 mA
  • Connection
    M12 Power, A-coded (X1)
  • Guard locking principle
    Closed-circuit current principle
  • Installation orientation
    Door hinge DIN right
  • Mechanical life
    0,1 x 10⁶
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Switching frequency
    0,25 Hz
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of protection
    IP54
  • Weight
    3,1 kg
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 128323 on MQ Automation is $3,137.56. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;3 illuminated pushbuttons;including adhesive labels;Connection via M12 plug;Pre-assembled on mounting plates;Unicode


Manufacturer warranty

128323 Euchner

$3,137.56

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,137.56

$3,137.56 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 128323 with other products

Weight

Series

Product Class

B10D

Mission time

Safety Integrity Level

Diagnostic Coverage (DC)

PFHD

Performance Level

Category

Product version number

Special features

Version

Switching element

Additional feature

Assignment diagram

Safety data protocol

Bus data protocol

Assured release distance ...

Auxiliary voltage DC

Operating voltage DC

Fusing

Transponder coding

Safety class

EMC protection requiremen...

Maximum feed-in current i...

Connecting cable

Locking force FZh

Rated insulation voltage ...

Rated impulse withstand v...

Degree of contamination (...

Current consumption

Connection

Guard locking principle

Installation orientation

Mechanical life

Reaction time

Housing material

Switching frequency

Shock and vibration resis...

Degree of protection

Ambient temperature

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

128323
0 in stock
128323
Euchner

128323 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, eme...

Weight8.19677716 lb

SeriesMGB-EI

Product ClassAccessories

B10D0,13 x 10⁶

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

Diagnostic Coverage (DC)99

PFHD3.37 x 10⁻⁹ (Fixed failure ...

Performance LevelPL e

Category4

Product version numberV1.2

Special featuresWith adhesive ring

VersionEmergency stop illuminated

Switching element2 pos. driven NC

Additional featureIncl. cover set ID. No. 1203...

Assignment diagramB1

Safety data protocolCIP Safety

Bus data protocolEthernet/IP

Assured release distance Sarmax.65 mm

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Fusingmin.1 A Slow blow

Transponder codingUnicode

Safety classIII

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Connecting cableEthernet/IP cable, Cat. 5e m...

Locking force FZh2000 N

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Current consumptionmax.500 mA

ConnectionM12 Power, A-coded (X1)

Guard locking principleClosed-circuit current princ...

Installation orientationDoor hinge DIN right

Mechanical life0,1 x 10⁶

Reaction timemax.250 ms Switch-off time...

Housing materialReinforced plastic, die-cast...

Switching frequency0,25 Hz

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP54

Ambient temperature-20 ... 55 °C

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Special features-

VersionEmergency stop

Switching element2 pos. driven NC

Additional feature-

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Fusing0,25 ... 8 A

Transponder coding-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Connecting cable-

Locking force FZh-

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Current consumption40 mA

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Reaction time-

Housing materialFiber glass reinforced therm...

Switching frequencymax.0,5 Hz

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Special features-

Version-

Switching element-

Additional featureEscape release actuated by p...

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Fusing0,25 ... 8 A

Transponder coding-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Connecting cable-

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Current consumption40 mA

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Installation orientationAny

Mechanical life1 x 10⁶

Reaction time-

Housing materialDie-cast zinc

Switching frequencymax.0,5 Hz

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 128323?
The price of 128323 on MQ Automation is $3,137.56. Order now.

Out if stock but available for backorder.

128323 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop

What can I help you find today?

Recommended parts