126637 Euchner Safety Accessories

126637 on MQ Automation
Euchner
  • 126637
  • 126637
  • 126637

Part#:126637

Alt. Part#:MGB-L1B-EIA-L-126637

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

126637 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 2 pushbuttons, emergency stop

Product Details

  • Weight
    2.20462 lb
  • Series
    MGB-EI
  • Product Class
    Accessories
  • Mission time
    20
  • PFHD
    3.37 x 10⁻⁹ (Fixed failure rate without consideration of faults in wearing parts.)
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • B10D
    0,13 x 10⁶
  • Diagnostic Coverage (DC)
    99
  • Additional feature
    Incl. cover set ID. No. 120344
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V1.2
  • Switching element
    2 pos. driven NC
  • Special features
    With adhesive ring
  • Safety data protocol
    CIP Safety
  • Assignment diagram
    B0
  • Version
    Emergency stop illuminated
  • Assured release distance Sar
    max.65 mm
  • Bus data protocol
    Ethernet/IP
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Transponder coding
    Unicode
  • Connecting cable
    Ethernet/IP cable, Cat. 5e min.
  • Safety class
    III
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    75 V
  • Current consumption
    max.500 mA
  • Guard locking principle
    Closed-circuit current principle
  • Locking force FZh
    2000 N
  • Connection
    M12 Power, A-coded (X1)
  • Switching frequency
    0,25 Hz
  • Weight
    3,1 kg
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Mechanical life
    0,1 x 10⁶
  • Installation orientation
    Door hinge DIN left
  • Degree of protection
    IP54
  • Ambient temperature
    -20 ... 55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 126637 on MQ Automation is $3,041.49. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;2 illuminated pushbuttons;including adhesive labels;Connection via M12 plug;Pre-assembled on mounting plates;Unicode


Manufacturer warranty

126637 Euchner

$3,041.49

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,041.49

$3,041.49 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 126637 with other products

Weight

Series

Product Class

Mission time

PFHD

Safety Integrity Level

B10D

Diagnostic Coverage (DC)

Additional feature

Performance Level

Category

Product version number

Switching element

Special features

Safety data protocol

Assignment diagram

Version

Assured release distance ...

Bus data protocol

Fusing

Auxiliary voltage DC

Operating voltage DC

Degree of contamination (...

Transponder coding

Connecting cable

Safety class

EMC protection requiremen...

Maximum feed-in current i...

Rated impulse withstand v...

Rated insulation voltage ...

Current consumption

Guard locking principle

Locking force FZh

Connection

Switching frequency

Reaction time

Mechanical life

Installation orientation

Degree of protection

Ambient temperature

Shock and vibration resis...

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

126637
0 in stock
126637
Euchner

126637 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 2 pushbuttons, eme...

Weight2.20462 lb

SeriesMGB-EI

Product ClassAccessories

Mission time20

PFHD3.37 x 10⁻⁹ (Fixed failure ...

Safety Integrity LevelSIL 3 (EN 62061:2005)

B10D0,13 x 10⁶

Diagnostic Coverage (DC)99

Additional featureIncl. cover set ID. No. 1203...

Performance LevelPL e

Category4

Product version numberV1.2

Switching element2 pos. driven NC

Special featuresWith adhesive ring

Safety data protocolCIP Safety

Assignment diagramB0

VersionEmergency stop illuminated

Assured release distance Sarmax.65 mm

Bus data protocolEthernet/IP

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Degree of contamination (external, according to EN 60947-1)3

Transponder codingUnicode

Connecting cableEthernet/IP cable, Cat. 5e m...

Safety classIII

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui75 V

Current consumptionmax.500 mA

Guard locking principleClosed-circuit current princ...

Locking force FZh2000 N

ConnectionM12 Power, A-coded (X1)

Switching frequency0,25 Hz

Reaction timemax.250 ms Switch-off time...

Mechanical life0,1 x 10⁶

Installation orientationDoor hinge DIN left

Degree of protectionIP54

Ambient temperature-20 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialReinforced plastic, die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Safety Integrity Level-

B10D0,13 x 10⁶

Diagnostic Coverage (DC)-

Additional feature-

Performance LevelPL e

Category4

Product version number-

Switching element2 pos. driven NC

Special features-

Safety data protocol-

Assignment diagram-

VersionEmergency stop

Assured release distance Sar-

Bus data protocol-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Connecting cable-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Guard locking principle-

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Reaction time-

Mechanical life1 x 10⁶

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Safety Integrity Level-

B10D-

Diagnostic Coverage (DC)-

Additional featureEscape release actuated by p...

Performance LevelPL e

Category4

Product version number-

Switching element-

Special features-

Safety data protocol-

Assignment diagram-

Version-

Assured release distance Sar-

Bus data protocol-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Connecting cable-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Guard locking principleClosed-circuit current princ...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Reaction time-

Mechanical life1 x 10⁶

Installation orientationAny

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 126637?
The price of 126637 on MQ Automation is $3,041.49. Order now.

Out if stock but available for backorder.

126637 Euchner - Locking module MGB-L1...-EI (guard locking by spring force) with 2 pushbuttons, emergency stop

What can I help you find today?

Recommended parts