122814 Euchner Safety Switches

122814 on MQ Automation
Euchner
  • 122814
  • 122814
  • 122814

Part#:122814

Alt. Part#:CTP-L2-AR-U-HA-AZ-SAB-122814

Manufacturer:Euchner

Category:Safety Switches

Product Lifecycle:Active

38 in stock

Mar 15, 2025

Product description

122814 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12

Product Details

  • Weight
    1.3007258 lb
  • Series
    CTP-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Category
    4
  • PFHD
    4.1 x 10 ⁻⁹
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    0,8xUB ... UB V DC
  • Turn-on time
    max.400 ms
  • Switching current
    1 ... 50 mA
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Type of output
    p-switching, short circuit-proof
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    6 W
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Fusing
    0,25 ... 8 A
  • Rated insulation voltage Ui
    50 V
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    40 mA
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Overtravel
    5 mm
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Test-pulse interval
    min.140 ms
  • Actuating force
    10 N
  • Retention force
    20 N
  • Extraction force
    20 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Locking force Fmax
    3900 N
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Ready delay
    8 s
  • Switching frequency
    max.0,5 Hz
  • Installation orientation
    Any
  • Mechanical life
    1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ambient temperature
    -20 ... +55 °C
  • Degree of protection
    IP67/IP69/IP69K (Screwed tight plug connector/mating component)
  • Weight
    0,42 kg
  • Housing material
    Die-cast zinc

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 122814 on MQ Automation is $772.00. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Approach directions A, B and C (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

122814 Euchner

$772.00

Your price can be lower.
Log in or Create account to check your discount

Stock:

38

Select Qty:

$772.00

$772.00 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 122814 with other products

Weight

Series

Product Class

Mission time

Category

PFHD

Performance Level

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Output voltage

Turn-on time

Switching current

Risk time according to EN...

Safety class

Degree of contamination (...

Switching load

Type of output

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Rated impulse withstand v...

Fusing

Rated insulation voltage ...

Solenoid operating voltag...

Current consumption

Utilization category acc....

Operating voltage DC

Test pulses

Overtravel

Extension of risk time ac...

Test-pulse interval

Actuating force

Retention force

Extraction force

Locking force FZh

Locking force Fmax

Guard locking principle

Approach speed

Connection

Ready delay

Switching frequency

Installation orientation

Mechanical life

Shock and vibration resis...

Ambient temperature

Degree of protection

Housing material

Additional feature

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

122814
38 in stock
122814
Euchner

122814 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12

Weight1.3007258 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Switching current1 ... 50 mA

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Switching load24V DC, class 2 (Alternativ...

Type of outputp-switching, short circuit-p...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.1,0 ms (Applies for a l...

Overtravel5 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Test-pulse intervalmin.140 ms

Actuating force10 N

Retention force20 N

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Ready delay8 s

Switching frequencymax.0,5 Hz

Installation orientationAny

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Additional feature-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Switching current1 ... 50 mA

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Switching load24V DC, class 2 (Alternativ...

Type of outputp-switching, short circuit-p...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.1,0 ms (Applies for a l...

Overtravel5 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Test-pulse intervalmin.140 ms

Actuating force10 N

Retention force20 N

Extraction force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Ready delay8 s

Switching frequencymax.0,5 Hz

Installation orientationAny

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Additional featureEscape release actuated by p...

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Switching current1 ... 150 mA

Risk time according to EN 60947-5-3-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Switching load24V DC, class 2 (Alternativ...

Type of output2 semiconductor outputs, p-s...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Rated impulse withstand voltage Uimp0,5 kV

Fusing0,25 ... 8 A

Rated insulation voltage Ui50 V

Solenoid operating voltage DC-

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.0,3 ms (Applies for a l...

Overtravel5 mm

Extension of risk time according to EN 60947-5-3 per device-

Test-pulse intervalmin.100 ms

Actuating force10 N

Retention force-

Extraction force20 N

Locking force FZh-

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Ready delaymax.1 s

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Additional feature-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 122814?
The price of 122814 on MQ Automation is $772.00. Order now.

Out if stock but available for backorder.

122814 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12

Similar products from: Safety Switches

What can I help you find today?

Recommended parts