121294 Euchner Safety Relays

121294 on MQ Automation
Euchner

Part#:121294

Alt. Part#:MSC-CE-AC-FO2-121294

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

Only 4 left in stock. Order Now!

Mar 15, 2025

Product description

121294 Euchner - EXPANSION MODULE MSC

Product Details

  • Weight
    0.460845 lb
  • SIL CL
    3 (Acc. to IEC 62061:2005)
  • PFHD
    4.09E-09 1/h (Acc. to IEC 61508:2010)
  • Mission time
    20 y (Acc. to ISO 13849-1:2006/IEC 62061:2005)
  • Category
    4 (Acc. to ISO 13849-1:2006/IEC 62061:2005)
  • Output voltage
    0 ... 2 V DC
  • Performance Level
    PL e (Acc. to ISO 13849-1:2006/IEC 62061:2005)
  • Inductive load
    max.30 mH
  • Capacitive load
    max.0,82 μF
  • Test pulses
    0,1 ms
  • Type of input
    Semiconductor inputs, p-switching (Acc. to EN 61131-2)
  • ESPE type
    4 (Acc. to EN 61496-1)
  • Output current
    max.100 mA
  • Type of output
    Semiconductor outputs, p-switching (Acc. to EN 61131-2)
  • Power consumption
    max.3 W
  • Connection cross-section
    0,5 ... 2,5 mm² (Screw terminal)
  • Delay time
    0,0106 ... 0,0546 s + filter time (Depending on the number of slave modules, operators and OSSD outputs. (See operating instructions and calculated values in the software "Euchner Safety Designer"))
  • Number of safety outputs
    2
  • Overvoltage category according to IEC EN 60664-1
    II
  • Degree of contamination according to EN 60664-1
    2
  • Operating voltage DC
    24 V DC -20% ... +20% PELV (Acc. to EN 60204-1)
  • Number of inputs
    2
  • Degree of protection
    IP20
  • Ambient temperature
    -10 ... +55 °C
  • Number of monitoring outputs
    2
  • Dimensions
    108 x 22.5 x 114.5 (Including screw terminals)
  • Material
    Polyamide
  • Cable length
    max.100 m (With length above 50m use cross-section >1mm2.)
  • Connection
    Plug-in screw terminal (Terminals not included)
  • Mounting method
    Mounting rail 35mm (Acc. to EN 60715)
  • Atmospheric humidity
    10 ... 95 % rH

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121294 on MQ Automation is $466.49. Order now.


This item can ship in 3-5 days!

Manufacturer warranty

121294 Euchner

$466.49

Your price can be lower.
Log in or Create account to check your discount

Stock:

4

Select Qty:

$466.49

$466.49 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121294 with other products

Weight

SIL CL

PFHD

Mission time

Category

Output voltage

Performance Level

Inductive load

Capacitive load

Test pulses

Type of input

ESPE type

Output current

Type of output

Power consumption

Connection cross-section

Delay time

Number of safety outputs

Overvoltage category acco...

Degree of contamination a...

Operating voltage DC

Number of inputs

Degree of protection

Ambient temperature

Number of monitoring outp...

Dimensions

Material

Cable length

Connection

Mounting method

Atmospheric humidity

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Utilization category acc....

Switching current

Turn-on time

Risk time according to EN...

Safety class

EMC protection requiremen...

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Switching frequency

Extension of risk time ac...

Current consumption

Ready delay

Tightening torque

Installation orientation

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Housing material

Static bending radius

Selected product

121294
4 in stock
121294
Euchner

121294 Euchner - EXPANSION MODULE MSC

Weight0.460845 lb

SIL CL3 (Acc. to IEC 62061:2005)

PFHD4.09E-09 1/h (Acc. to IEC 6...

Mission time20 y (Acc. to ISO 13849-1:...

Category4 (Acc. to ISO 13849-1:2006...

Output voltage0 ... 2 V DC

Performance LevelPL e (Acc. to ISO 13849-1:2...

Inductive loadmax.30 mH

Capacitive loadmax.0,82 μF

Test pulses0,1 ms

Type of inputSemiconductor inputs, p-swit...

ESPE type4 (Acc. to EN 61496-1)

Output currentmax.100 mA

Type of outputSemiconductor outputs, p-swi...

Power consumptionmax.3 W

Connection cross-section0,5 ... 2,5 mm² (Screw term...

Delay time0,0106 ... 0,0546 s + filt...

Number of safety outputs2

Overvoltage category according to IEC EN 60664-1II

Degree of contamination according to EN 60664-12

Operating voltage DC24 V DC -20% ... +20% PE...

Number of inputs2

Degree of protectionIP20

Ambient temperature-10 ... +55 °C

Number of monitoring outputs2

Dimensions108 x 22.5 x 114.5 (Includi...

MaterialPolyamide

Cable lengthmax.100 m (With length abov...

ConnectionPlug-in screw terminal (Ter...

Mounting methodMounting rail 35mm (Acc. to...

Atmospheric humidity10 ... 95 % rH

Series-

Product Class-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Tightening torque-

Installation orientation-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Housing material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SIL CL-

PFHD4.1 x 10⁻⁹

Mission time20

Category4

Output voltage0,8 x UB ... UB V DC

Performance LevelPL e

Inductive load-

Capacitive load-

Test pulsesmax.1,0 ms (Applies for a l...

Type of input-

ESPE type-

Output current-

Type of outputSemiconductor output, p-swit...

Power consumption-

Connection cross-section-

Delay time-

Number of safety outputs-

Overvoltage category according to IEC EN 60664-1-

Degree of contamination according to EN 60664-1-

Operating voltage DC24 V DC 15% ... 15% Regu...

Number of inputs-

Degree of protectionIP67

Ambient temperature-

Number of monitoring outputs-

Dimensions-

MaterialNBR 80 ±5 Shore

Cable length-

ConnectionConnection cable PUR, length...

Mounting methodSurface mounting on metal

Atmospheric humidity-

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking i...

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SIL CL-

PFHD1.9 x 10⁻⁹

Mission time20

Category4

Output voltage0,8 x UB ... UB V DC

Performance LevelPL e

Inductive load-

Capacitive load-

Test pulsesmax.1 ms (Applies for a loa...

Type of input-

ESPE type-

Output current-

Type of outputp-switching, short circuit-p...

Power consumption-

Connection cross-section-

Delay time-

Number of safety outputs-

Overvoltage category according to IEC EN 60664-1-

Degree of contamination according to EN 60664-1-

Operating voltage DC24 V DC 15% ... 15% Regu...

Number of inputs-

Degree of protectionIP67

Ambient temperature-

Number of monitoring outputs-

Dimensions-

Material-

Cable length-

ConnectionConnection cable PUR, length...

Mounting methodSurface mounting on metal

Atmospheric humidity-

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.50 mA (Without taking i...

Ready delay10 s

Tightening torquemax.1 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.120 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121294?
The price of 121294 on MQ Automation is $466.49. Order now.

Out if stock but available for backorder.

121294 Euchner - EXPANSION MODULE MSC

What can I help you find today?

Recommended parts