121208 Euchner Safety Accessories

121208 on MQ Automation
Euchner
  • 121208
  • 121208
  • 121208

Part#:121208

Alt. Part#:MGB-L1-ARA-AM3A1-S6-R-121208

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121208 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC26

Product Details

  • Weight
    2.866006 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Product version number
    V4.0.0
  • Performance Level
    PL e
  • Category
    4
  • Switching element
    2 pos. driven NC + 1NO
  • Additional feature
    Incl. cover set ID. No. 120344
  • Special features
    With auxiliary contact
  • Version
    Emergency stop
  • Assignment diagram
    L1
  • Output voltage
    0 ... 1 V DC
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Test pulses
    max.1 ms
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Locking force FZh
    2000 N
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Installation orientation
    Door hinge DIN right
  • Degree of protection
    IP65
  • Guard locking principle
    Closed-circuit current principle
  • Ambient temperature
    -20 ... 55 °C
  • Connection
    Plug connector RC26 (X6)
  • Switching frequency
    0,25 Hz
  • Mechanical life
    0,1 x 10⁶
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121208 on MQ Automation is $1,631.85. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated);With lens set, 6 pcs.;incl. adhesive labels;With plug connector RC26;Unicode


Manufacturer warranty

121208 Euchner

$1,631.85

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,631.85

$1,631.85 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121208 with other products

Weight

Series

Product Class

B10D

Mission time

PFHD

Product version number

Performance Level

Category

Switching element

Additional feature

Special features

Version

Assignment diagram

Output voltage

Power supply LED

Breaking capacity

Switching current

Switching voltage

Output current

Type of output

Test-pulse interval

Current consumption

Test pulses

Operating voltage DC

Transponder coding

Degree of contamination (...

Discrepancy time

Safety class

Risk time according to EN...

Rated impulse withstand v...

Utilization category acc....

Rated insulation voltage ...

Locking force FZh

Housing material

Installation orientation

Degree of protection

Guard locking principle

Ambient temperature

Connection

Switching frequency

Mechanical life

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

121208
0 in stock
121208
Euchner

121208 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, e...

Weight2.866006 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Mission time20 y

PFHD3.7 x 10⁻⁹

Product version numberV4.0.0

Performance LevelPL e

Category4

Switching element2 pos. driven NC + 1NO

Additional featureIncl. cover set ID. No. 1203...

Special featuresWith auxiliary contact

VersionEmergency stop

Assignment diagramL1

Output voltage0 ... 1 V DC

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Current consumptionmax.80 mA ((no load on outp...

Test pulsesmax.1 ms

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Degree of contamination (external, according to EN 60947-1)3

Discrepancy timemax.10 ms

Safety classIII

Risk time according to EN 60947-5-3max.350 ms

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Locking force FZh2000 N

Housing materialReinforced plastic; die-cast...

Installation orientationDoor hinge DIN right

Degree of protectionIP65

Guard locking principleClosed-circuit current princ...

Ambient temperature-20 ... 55 °C

ConnectionPlug connector RC26 (X6)

Switching frequency0,25 Hz

Mechanical life0,1 x 10⁶

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Product version number-

Performance LevelPL e

Category4

Switching element2 pos. driven NC

Additional feature-

Special features-

VersionEmergency stop

Assignment diagram-

Output voltage0 ... 1 V DC

Power supply LED-

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Output current-

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Current consumption40 mA

Test pulsesmax.0,3 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Risk time according to EN 60947-5-3-

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh-

Housing materialFiber glass reinforced therm...

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Guard locking principle-

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Product version number-

Performance LevelPL e

Category4

Switching element-

Additional featureEscape release actuated by p...

Special features-

Version-

Assignment diagram-

Output voltage0,8xUB ... UB V DC

Power supply LED-

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Output current-

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Current consumption40 mA

Test pulsesmax.1,0 ms (Applies for a l...

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Housing materialDie-cast zinc

Installation orientationAny

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Guard locking principleClosed-circuit current princ...

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121208?
The price of 121208 on MQ Automation is $1,631.85. Order now.

Out if stock but available for backorder.

121208 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC26

What can I help you find today?

Recommended parts