121290 Euchner - EXPANSION MODULE MSC

Product Details

  • Weight
    0.4851 lb
  • Mission time
    20 y (Acc. to ISO 13849-1:2006/IEC 62061:2005)
  • SIL CL
    3 (Acc. to IEC 62061:2005)
  • PFHD
    5.72E-09 1/h (Acc. to IEC 61508:2010)
  • Performance Level
    PL e (Acc. to ISO 13849-1:2006/IEC 62061:2005)
  • Inductive load
    max.30 mH
  • Category
    4 (Acc. to ISO 13849-1:2006/IEC 62061:2005)
  • ESPE type
    4 (Acc. to EN 61496-1)
  • Capacitive load
    max.0,82 μF
  • Output current
    max.100 mA
  • Output voltage
    UB-0,75 ... UB V DC
  • Type of output
    Semiconductor outputs, p-switching (Acc. to EN 61131-2)
  • Type of input
    Semiconductor inputs, p-switching (Acc. to EN 61131-2)
  • Test pulses
    0,2 ms
  • Degree of contamination according to EN 60664-1
    2
  • Overvoltage category according to IEC EN 60664-1
    II
  • Power consumption
    max.3 W
  • Delay time
    0,0106 ... 0,0546 s + filter time (Depending on the number of slave modules, operators and OSSD outputs. (See operating instructions and calculated values in the software "Euchner Safety Designer"))
  • Connection cross-section
    0,5 ... 2,5 mm² (Screw terminal)
  • Number of safety outputs
    2
  • Operating voltage DC
    24 V DC -20% ... +20% PELV (Acc. to EN 60204-1)
  • Dimensions
    108 x 22.5 x 114.5 (Including screw terminals)
  • Material
    Polyamide
  • Ambient temperature
    -10 ... +55 °C
  • Cable length
    max.100 m (With length above 50m use cross-section >1mm2.)
  • Degree of protection
    IP20
  • Connection
    Plug-in screw terminal (Terminals not included)
  • Mounting method
    Mounting rail 35mm (Acc. to EN 60715)
  • Number of monitoring outputs
    2
  • Number of outputs
    4
  • Atmospheric humidity
    10 ... 95 % rH
  • Number of inputs
    8

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121290 on MQ Automation is $529.65. Order now.


This item can ship in 3-5 days!

Manufacturer warranty

121290 Euchner

$529.65

Your price can be lower.
Log in or Create account to check your discount

Stock:

4

Select Qty:

$529.65

$529.65 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121290 with other products

Weight

Mission time

SIL CL

PFHD

Performance Level

Inductive load

Category

ESPE type

Capacitive load

Output current

Output voltage

Type of output

Type of input

Test pulses

Degree of contamination a...

Overvoltage category acco...

Power consumption

Delay time

Connection cross-section

Number of safety outputs

Operating voltage DC

Dimensions

Material

Ambient temperature

Cable length

Degree of protection

Connection

Mounting method

Number of monitoring outp...

Number of outputs

Atmospheric humidity

Number of inputs

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Utilization category acc....

Switching current

Turn-on time

Risk time according to EN...

Safety class

EMC protection requiremen...

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Switching frequency

Extension of risk time ac...

Current consumption

Ready delay

Tightening torque

Installation orientation

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Housing material

Static bending radius

Selected product

121290
4 in stock
121290
Euchner

121290 Euchner - EXPANSION MODULE MSC

Weight0.4851 lb

Mission time20 y (Acc. to ISO 13849-1:...

SIL CL3 (Acc. to IEC 62061:2005)

PFHD5.72E-09 1/h (Acc. to IEC 6...

Performance LevelPL e (Acc. to ISO 13849-1:2...

Inductive loadmax.30 mH

Category4 (Acc. to ISO 13849-1:2006...

ESPE type4 (Acc. to EN 61496-1)

Capacitive loadmax.0,82 μF

Output currentmax.100 mA

Output voltageUB-0,75 ... UB V DC

Type of outputSemiconductor outputs, p-swi...

Type of inputSemiconductor inputs, p-swit...

Test pulses0,2 ms

Degree of contamination according to EN 60664-12

Overvoltage category according to IEC EN 60664-1II

Power consumptionmax.3 W

Delay time0,0106 ... 0,0546 s + filt...

Connection cross-section0,5 ... 2,5 mm² (Screw term...

Number of safety outputs2

Operating voltage DC24 V DC -20% ... +20% PE...

Dimensions108 x 22.5 x 114.5 (Includi...

MaterialPolyamide

Ambient temperature-10 ... +55 °C

Cable lengthmax.100 m (With length abov...

Degree of protectionIP20

ConnectionPlug-in screw terminal (Ter...

Mounting methodMounting rail 35mm (Acc. to...

Number of monitoring outputs2

Number of outputs4

Atmospheric humidity10 ... 95 % rH

Number of inputs8

Series-

Product Class-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Tightening torque-

Installation orientation-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Housing material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

Mission time20

SIL CL-

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Inductive load-

Category4

ESPE type-

Capacitive load-

Output current-

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

Type of input-

Test pulsesmax.1,0 ms (Applies for a l...

Degree of contamination according to EN 60664-1-

Overvoltage category according to IEC EN 60664-1-

Power consumption-

Delay time-

Connection cross-section-

Number of safety outputs-

Operating voltage DC24 V DC 15% ... 15% Regu...

Dimensions-

MaterialNBR 80 ±5 Shore

Ambient temperature-

Cable length-

Degree of protectionIP67

ConnectionConnection cable PUR, length...

Mounting methodSurface mounting on metal

Number of monitoring outputs-

Number of outputs-

Atmospheric humidity-

Number of inputs-

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking i...

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

Mission time20

SIL CL-

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Inductive load-

Category4

ESPE type-

Capacitive load-

Output current-

Output voltage0,8 x UB ... UB V DC

Type of outputp-switching, short circuit-p...

Type of input-

Test pulsesmax.1 ms (Applies for a loa...

Degree of contamination according to EN 60664-1-

Overvoltage category according to IEC EN 60664-1-

Power consumption-

Delay time-

Connection cross-section-

Number of safety outputs-

Operating voltage DC24 V DC 15% ... 15% Regu...

Dimensions-

Material-

Ambient temperature-

Cable length-

Degree of protectionIP67

ConnectionConnection cable PUR, length...

Mounting methodSurface mounting on metal

Number of monitoring outputs-

Number of outputs-

Atmospheric humidity-

Number of inputs-

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.50 mA (Without taking i...

Ready delay10 s

Tightening torquemax.1 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.120 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121290?
The price of 121290 on MQ Automation is $529.65. Order now.

Out if stock but available for backorder.

121290 Euchner - EXPANSION MODULE MSC

What can I help you find today?

Recommended parts