119476 Euchner Safety Proximity Sensors

119476 on MQ Automation
Euchner
  • 119476
  • 119476
  • 119476

Part#:119476

Alt. Part#:CES-I-AR-M-C04-U10-119476

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

10 in stock

Mar 15, 2025

Product description

119476 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, flying lead

Product Details

  • Weight
    0.8377556 lb
  • Series
    CES-AR
  • Product Class
    Safety System
  • Switching hysteresis
    min.1 mm
  • Mission time
    20
  • Assured operating distance Sao
    min.10 mm
  • Assured release distance Sar
    max.60 mm
  • PFHD
    4.1 x 10⁻⁹
  • Category
    4
  • Performance Level
    PL e
  • Operating distance
    15 mm
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Additional feature
    Rubber support included
  • Discrepancy time
    max.10 ms
  • Test-pulse interval
    min.140 ms
  • Repeat accuracy R
    ≤ 10
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Rated conditional short-circuit current
    100 A
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Output voltage
    0,8 x UB ... UB V DC
  • Off-state current Ir
    max.0,25 mA
  • Switching current
    max.50 mA
  • Type of output
    Semiconductor output, p-switching, short circuit-proof
  • Turn-on time
    max.400 ms
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Safety class
    III
  • Current consumption
    max.35 mA (Without taking into account the load currents on the monitoring output and the safety outputs)
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    300 V
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Mounting distance
    min.80 mm
  • Switching frequency
    max.1 Hz
  • Ready delay
    10 s
  • Connection
    connection cable PUR, length 10m
  • Tightening torque
    max.0,8 Nm
  • Installation orientation
    Any
  • Degree of protection
    IP67
  • Mounting method
    Surface mounting on metal
  • Cable ambient temperature (static)
    -25 ... 65 °C
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C
  • Weight
    0,36 kg
  • Material
    NBR 80 ±5 Shore
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Dynamic bending radius
    10 x cable diameter
  • Housing material
    Plastic, PBT
  • Static bending radius
    5 x cable diameter

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 119476 on MQ Automation is $274.79. Order now.


About the product

Safety switch with integrated evaluation electronics;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Three active faces;Connecting cable PUR, 10 m, flying lead, 8-core;Multicode


This item can ship in 3-5 days!

Manufacturer warranty

119476 Euchner

$274.79

Your price can be lower.
Log in or Create account to check your discount

Stock:

10

Select Qty:

$274.79

$274.79 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 119476 with other products

Weight

Series

Product Class

Switching hysteresis

Mission time

Assured operating distanc...

Assured release distance ...

PFHD

Category

Performance Level

Operating distance

For the approval acc. to ...

Additional feature

Discrepancy time

Test-pulse interval

Repeat accuracy R

Test pulses

Rated conditional short-c...

Utilization category acc....

Output voltage

Off-state current Ir

Switching current

Type of output

Turn-on time

Risk time according to EN...

Rated impulse withstand v...

Safety class

Current consumption

EMC protection requiremen...

Degree of contamination (...

Rated insulation voltage ...

Fusing

Operating voltage DC

Extension of risk time ac...

Mounting distance

Switching frequency

Ready delay

Connection

Tightening torque

Installation orientation

Degree of protection

Mounting method

Cable ambient temperature...

Cable ambient temperature...

Material

Shock and vibration resis...

Dynamic bending radius

Housing material

Static bending radius

Selected product

119476
10 in stock
119476
Euchner

119476 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, flying lead

Weight0.8377556 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Mission time20

Assured operating distance Saomin.10 mm

Assured release distance Sarmax.60 mm

PFHD4.1 x 10⁻⁹

Category4

Performance LevelPL e

Operating distance15 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Discrepancy timemax.10 ms

Test-pulse intervalmin.140 ms

Repeat accuracy R≤ 10

Test pulsesmax.1,0 ms (Applies for a l...

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Type of outputSemiconductor output, p-swit...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Current consumptionmax.35 mA (Without taking i...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.80 mm

Switching frequencymax.1 Hz

Ready delay10 s

Connectionconnection cable PUR, length...

Tightening torquemax.0,8 Nm

Installation orientationAny

Degree of protectionIP67

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

MaterialNBR 80 ±5 Shore

Shock and vibration resistanceIn acc. with EN 60947-5-3

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Mission time20

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

PFHD4.1 x 10⁻⁹

Category4

Performance LevelPL e

Operating distance11 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Discrepancy timemax.10 ms

Test-pulse intervalmin.140 ms

Repeat accuracy R≤ 10

Test pulsesmax.1,0 ms (Applies for a l...

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Type of outputSemiconductor output, p-swit...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Current consumptionmax.35 mA (Without taking i...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.80 mm

Switching frequencymax.1 Hz

Ready delay10 s

ConnectionConnection cable PUR, length...

Tightening torquemax.0,8 Nm

Installation orientationAny

Degree of protectionIP67

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

MaterialNBR 80 ±5 Shore

Shock and vibration resistanceIn acc. with EN 60947-5-3

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Mission time20

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Category4

Performance LevelPL e

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Discrepancy timemax.10 ms

Test-pulse intervalmin.140 ms

Repeat accuracy R≤ 10

Test pulsesmax.1 ms (Applies for a loa...

Rated conditional short-circuit current100 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Current consumptionmax.50 mA (Without taking i...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.120 mm

Switching frequencymax.1 Hz

Ready delay10 s

ConnectionConnection cable PUR, length...

Tightening torquemax.1 Nm

Installation orientationAny

Degree of protectionIP67

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Material-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 119476?
The price of 119476 on MQ Automation is $274.79. Order now.

Out if stock but available for backorder.

119476 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, flying lead

What can I help you find today?

Recommended parts