Product Details

  • Weight
    1.53662014 lb
  • Series
    CES-AR
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.10 mm
  • Switching hysteresis
    min.1 mm
  • Assured release distance Sar
    max.60 mm
  • Operating distance
    15 mm
  • Performance Level
    PL e
  • Mission time
    20
  • PFHD
    4.1 x 10⁻⁹
  • Additional feature
    Rubber support included
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Category
    4
  • Discrepancy time
    max.10 ms
  • Repeat accuracy R
    ≤ 10
  • Off-state current Ir
    max.0,25 mA
  • Rated conditional short-circuit current
    100 A
  • Test-pulse interval
    min.140 ms
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Output voltage
    0,8 x UB ... UB V DC
  • Type of output
    Semiconductor output, p-switching, short circuit-proof
  • Switching current
    max.50 mA
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Turn-on time
    max.400 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Rated insulation voltage Ui
    300 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Fusing
    0,25 ... 8 A
  • Current consumption
    max.35 mA (Without taking into account the load currents on the monitoring output and the safety outputs)
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Ready delay
    10 s
  • Switching frequency
    max.1 Hz
  • Connection
    connection cable PUR, length 20m
  • Tightening torque
    max.0,8 Nm
  • Installation orientation
    Any
  • Mounting method
    Surface mounting on metal
  • Mounting distance
    min.80 mm
  • Degree of protection
    IP67
  • Dynamic bending radius
    10 x cable diameter
  • Cable ambient temperature (static)
    -25 ... 65 °C
  • Housing material
    Plastic, PBT
  • Weight
    0,7 kg
  • Material
    NBR 80 ±5 Shore
  • Static bending radius
    5 x cable diameter
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 119472 on MQ Automation is $391.79. Order now.


About the product

Safety switch with integrated evaluation electronics;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Three active faces;Connecting cable PUR, 20 m, flying lead, 8-core;Unicode


Manufacturer warranty

119472 Euchner

$391.79

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$391.79

$391.79 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 119472 with other products

Weight

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Performance Level

Mission time

PFHD

Additional feature

For the approval acc. to ...

Category

Discrepancy time

Repeat accuracy R

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Test pulses

Utilization category acc....

Output voltage

Type of output

Switching current

Safety class

Risk time according to EN...

Turn-on time

Degree of contamination (...

EMC protection requiremen...

Rated insulation voltage ...

Rated impulse withstand v...

Fusing

Current consumption

Operating voltage DC

Extension of risk time ac...

Ready delay

Switching frequency

Connection

Tightening torque

Installation orientation

Mounting method

Mounting distance

Degree of protection

Dynamic bending radius

Cable ambient temperature...

Housing material

Material

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Selected product

119472
0 in stock
119472
Euchner

119472 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, flying lead

Weight1.53662014 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.10 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance15 mm

Performance LevelPL e

Mission time20

PFHD4.1 x 10⁻⁹

Additional featureRubber support included

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Discrepancy timemax.10 ms

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

Switching currentmax.50 mA

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Current consumptionmax.35 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Switching frequencymax.1 Hz

Connectionconnection cable PUR, length...

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Mounting distancemin.80 mm

Degree of protectionIP67

Dynamic bending radius10 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Housing materialPlastic, PBT

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (dynamic)-25 ... 65 °C

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Performance LevelPL e

Mission time20

PFHD4.1 x 10⁻⁹

Additional featureRubber support included

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Discrepancy timemax.10 ms

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

Switching currentmax.50 mA

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Current consumptionmax.35 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Switching frequencymax.1 Hz

ConnectionConnection cable PUR, length...

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Mounting distancemin.80 mm

Degree of protectionIP67

Dynamic bending radius10 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Housing materialPlastic, PBT

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (dynamic)-25 ... 65 °C

109052
68 in stock
109052
Euchner

109052 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Weight1.763696 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.10 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.40 mm

Operating distance15 mm

Performance LevelPL e

Mission time20

PFHD1.9 x 10⁻⁹

Additional feature-

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Discrepancy timemax.10 ms

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Test pulsesmax.1 ms (Applies for a loa...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Type of outputp-switching, short circuit-p...

Switching currentmax.50 mA

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Current consumptionmax.50 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Switching frequencymax.1 Hz

Connectionconnection cable PUR, length...

Tightening torquemax.1 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Mounting distancemin.120 mm

Degree of protectionIP67, IP69K

Dynamic bending radius10 x cable diameter

Cable ambient temperature (static)-30 ... 65 °C

Housing materialPlastic, PBT

Material-

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (dynamic)-25 ... 65 °C

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 119472?
The price of 119472 on MQ Automation is $391.79. Order now.

Out if stock but available for backorder.

119472 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, flying lead

What can I help you find today?

Recommended parts