Product description

119111 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Product Details

  • Weight
    6.62382 lb
  • Mission time
    20
  • Diagnostic Coverage (DC)
    99
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Performance Level
    PL e
  • PFHD
    4.1 x 10⁻⁸
  • Color
    white
  • Category
    4
  • Version
    Illuminated push buttons
  • Switching element
    1NO
  • B10D
    0,13 x 10⁶
  • Product version number
    V3.30.10
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Assignment diagram
    B1
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Operating voltage DC
    24 V DC -15% ... 10% (For looping through for connected devices)
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (For looping through for connected devices)
  • Fusing
    min.1 A Slow blow
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Rated insulation voltage Ui
    75 V
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Current consumption
    max.500 mA
  • Connection
    Push-pull RJ45 (X3 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Weight
    2,7 kg
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Switching frequency
    0,25 Hz
  • Installation orientation
    Any
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP54

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 119111 on MQ Automation is $4,355.71. Order now.


Manufacturer warranty

119111 Euchner

$4,355.71

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$4,355.71

$4,355.71 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 119111 with other products

Weight

Mission time

Diagnostic Coverage (DC)

Safety Integrity Level

Performance Level

PFHD

Color

Category

Version

Switching element

B10D

Product version number

Safety data protocol

Assignment diagram

Bus data protocol

Operating voltage DC

Auxiliary voltage DC

Fusing

Safety class

Degree of contamination (...

Connecting cable

Rated impulse withstand v...

EMC protection requiremen...

Rated insulation voltage ...

Maximum feed-in current i...

Current consumption

Connection

Shock and vibration resis...

Housing material

Reaction time

Switching frequency

Installation orientation

Ambient temperature

Degree of protection

Series

Product Class

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Mechanical life

Approach speed

Ready delay

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Risk time according to EN...

Extension of risk time ac...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

119111
0 in stock
119111
Euchner

119111 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Weight6.62382 lb

Mission time20

Diagnostic Coverage (DC)99

Safety Integrity LevelSIL 3 (EN 62061:2005)

Performance LevelPL e

PFHD4.1 x 10⁻⁸

Colorwhite

Category4

VersionIlluminated push buttons

Switching element1NO

B10D0,13 x 10⁶

Product version numberV3.30.10

Safety data protocolProfisafe (IEC 61784-3-3)

Assignment diagramB1

Bus data protocolProfinet (IEC 61158 type 10)

Operating voltage DC24 V DC -15% ... 10% (For...

Auxiliary voltage DC24 V DC -15% ... +10% (Fo...

Fusingmin.1 A Slow blow

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cableProfinet I/O cable, at least...

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn accordance with EN 61000-...

Rated insulation voltage Ui75 V

Maximum feed-in current in the connection blockmax.4000 mA

Current consumptionmax.500 mA

ConnectionPush-pull RJ45 (X3 (The doc...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialReinforced plastic, die-cast...

Reaction timemax.250 ms Switch-off time...

Switching frequency0,25 Hz

Installation orientationAny

Ambient temperature-20 ... 55 °C

Degree of protectionIP54

Series-

Product Class-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Mechanical life-

Approach speed-

Ready delay-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

Mission time20 y

Diagnostic Coverage (DC)-

Safety Integrity Level-

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Color-

Category4

VersionEmergency stop

Switching element2 pos. driven NC

B10D0,13 x 10⁶

Product version number-

Safety data protocol-

Assignment diagram-

Bus data protocol-

Operating voltage DC24 V DC -15% ... 15% Rev...

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui50 V

Maximum feed-in current in the connection block-

Current consumption40 mA

Connection2 plug connectors M12, 5-pin

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced therm...

Reaction time-

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

SeriesMGBS-P-I-AP

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Mechanical life1 x 10⁶

Approach speedmax.20 m/min

Ready delaymax.1 s

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

Mission time20

Diagnostic Coverage (DC)-

Safety Integrity Level-

Performance LevelPL e

PFHD1.9 x 10⁻⁹

Color-

Category4

Version-

Switching element-

B10D-

Product version number-

Safety data protocol-

Assignment diagram-

Bus data protocol-

Operating voltage DC24 V DC 15% ... 15% Regu...

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Rated impulse withstand voltage Uimp1,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui75 V

Maximum feed-in current in the connection block-

Current consumptionmax.50 mA (Without taking i...

ConnectionConnection cable PUR, length...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

Reaction time-

Switching frequencymax.1 Hz

Installation orientationAny

Ambient temperature-

Degree of protectionIP67

SeriesCES-AR

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R≤ 10

Detent mechanism-

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Operating voltage-

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load-

Output voltage0,8 x UB ... UB V DC

Connection rating-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Overtravel-

Test-pulse intervalmin.140 ms

Extraction force-

Test pulsesmax.1 ms (Applies for a loa...

Actuating force-

Mechanical life-

Approach speed-

Ready delay10 s

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 119111?
The price of 119111 on MQ Automation is $4,355.71. Order now.

Out if stock but available for backorder.

119111 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

What can I help you find today?

Recommended parts