116523 Euchner Safety Accessories

116523 on MQ Automation
Euchner
  • 116523
  • 116523

Part#:116523

Alt. Part#:MGB-L2B-PNC-L-116523

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

116523 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, push-pull plug, RC12

Product Details

  • Weight
    7.73380696 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Diagnostic Coverage (DC)
    99
  • Mission time
    20
  • B10D
    (According to manufacturer’s specifications)
  • PFHD
    4.1 x 10⁻⁸
  • Category
    4
  • Performance Level
    PL e
  • Product version number
    V3.30.11
  • Switching element
    1NO
  • Color
    white
  • Special features
    Printed
  • Version
    Illuminated push buttons
  • Assignment diagram
    B1
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Multicode
  • Safety class
    III
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Guard locking principle
    Open-circuit current principle
  • Current consumption
    max.500 mA
  • Rated insulation voltage Ui
    75 V
  • Locking force FZh
    2000 N
  • Connection
    Push-pull RJ45 (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP54
  • Installation orientation
    Door hinge DIN left
  • Mechanical life
    0,1 x 10⁶
  • Weight
    3,1 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 116523 on MQ Automation is $2,907.56. Order now.


About the product

Guard locking with guard lock monitoring;3 illuminated pushbuttons;Push-pull plug;including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Multicode


Manufacturer warranty

116523 Euchner

$2,907.56

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,907.56

$2,907.56 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 116523 with other products

Weight

Series

Product Class

Safety Integrity Level

Diagnostic Coverage (DC)

Mission time

B10D

PFHD

Category

Performance Level

Product version number

Switching element

Color

Special features

Version

Assignment diagram

Safety data protocol

Bus data protocol

Assured release distance ...

Fusing

Auxiliary voltage DC

Operating voltage DC

Transponder coding

Safety class

Connecting cable

Degree of contamination (...

EMC protection requiremen...

Maximum feed-in current i...

Rated impulse withstand v...

Guard locking principle

Current consumption

Rated insulation voltage ...

Locking force FZh

Connection

Housing material

Reaction time

Switching frequency

Degree of protection

Installation orientation

Mechanical life

Shock and vibration resis...

Ambient temperature

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

116523
0 in stock
116523
Euchner

116523 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) ...

Weight7.73380696 lb

SeriesSpare parts

Product ClassAccessories

Safety Integrity LevelSIL 3 (EN 62061:2005)

Diagnostic Coverage (DC)99

Mission time20

B10D(According to manufacturer’s...

PFHD4.1 x 10⁻⁸

Category4

Performance LevelPL e

Product version numberV3.30.11

Switching element1NO

Colorwhite

Special featuresPrinted

VersionIlluminated push buttons

Assignment diagramB1

Safety data protocolProfisafe (IEC 61784-3-3)

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingMulticode

Safety classIII

Connecting cableProfinet I/O cable, at least...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Rated impulse withstand voltage Uimp0,5 kV

Guard locking principleOpen-circuit current princip...

Current consumptionmax.500 mA

Rated insulation voltage Ui75 V

Locking force FZh2000 N

ConnectionPush-pull RJ45 (X4 (The doc...

Housing materialReinforced plastic, die-cast...

Reaction timemax.250 ms Switch-off time...

Switching frequency0,25 Hz

Degree of protectionIP54

Installation orientationDoor hinge DIN left

Mechanical life0,1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... 55 °C

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Safety Integrity Level-

Diagnostic Coverage (DC)-

Mission time20 y

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

Switching element2 pos. driven NC

Color-

Special features-

VersionEmergency stop

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Guard locking principle-

Current consumption40 mA

Rated insulation voltage Ui50 V

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Reaction time-

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Safety Integrity Level-

Diagnostic Coverage (DC)-

Mission time20 y

B10D-

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

Switching element-

Color-

Special features-

Version-

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Guard locking principleClosed-circuit current princ...

Current consumption40 mA

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Reaction time-

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 116523?
The price of 116523 on MQ Automation is $2,907.56. Order now.

Out if stock but available for backorder.

116523 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, push-pull plug, RC12

What can I help you find today?

Recommended parts