116301 Euchner Safety Accessories

116301 on MQ Automation
Euchner
  • 116301
  • 116301
  • 116301

Part#:116301

Alt. Part#:MGB-L1-ARA-AA2A1-S1-R-116301

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

116301 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    2.4030358 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V4.0.0
  • Switching element
    2 pos. driven NC
  • Version
    Emergency stop
  • Power supply LED
    24 V DC
  • Switching current
    1 ... 10 mA
  • Assignment diagram
    L1
  • Switching voltage
    UA V
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Breaking capacity
    max.0,25 W
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Output current
    1 ... 200 mA
  • Test pulses
    max.1 ms
  • Test-pulse interval
    min.100 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Safety class
    III
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Discrepancy time
    max.10 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    30 V
  • Installation orientation
    Door hinge DIN right
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Connection
    Plug connector RC18 (X6)
  • Ambient temperature
    -20 ... 55 °C
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Locking force FZh
    2000 N
  • Guard locking principle
    Closed-circuit current principle
  • Weight
    0,75 kg
  • Degree of protection
    IP65
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 116301 on MQ Automation is $1,483.64. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode;Release monitoring


Manufacturer warranty

116301 Euchner

$1,483.64

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,483.64

$1,483.64 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 116301 with other products

Weight

Series

Product Class

B10D

Mission time

PFHD

Performance Level

Category

Product version number

Switching element

Version

Power supply LED

Switching current

Assignment diagram

Switching voltage

Output voltage

Breaking capacity

Type of output

Output current

Test pulses

Test-pulse interval

Current consumption

Safety class

Operating voltage DC

Transponder coding

Risk time according to EN...

Rated impulse withstand v...

Discrepancy time

Degree of contamination (...

Rated insulation voltage ...

Installation orientation

Mechanical life

Switching frequency

Connection

Ambient temperature

Utilization category acc....

Locking force FZh

Guard locking principle

Degree of protection

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

116301
0 in stock
116301
Euchner

116301 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, em...

Weight2.4030358 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

Product version numberV4.0.0

Switching element2 pos. driven NC

VersionEmergency stop

Power supply LED24 V DC

Switching current1 ... 10 mA

Assignment diagramL1

Switching voltageU<sub>A</sub> V

Output voltageUB-2V ... UB V DC (Value at...

Breaking capacitymax.0,25 W

Type of outputSemiconductor outputs, p-swi...

Output current1 ... 200 mA

Test pulsesmax.1 ms

Test-pulse intervalmin.100 ms

Current consumptionmax.80 mA ((no load on outp...

Safety classIII

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Rated impulse withstand voltage Uimp1,5 kV

Discrepancy timemax.10 ms

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui30 V

Installation orientationDoor hinge DIN right

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

ConnectionPlug connector RC18 (X6)

Ambient temperature-20 ... 55 °C

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh2000 N

Guard locking principleClosed-circuit current princ...

Degree of protectionIP65

Housing materialReinforced plastic; die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Switching element2 pos. driven NC

VersionEmergency stop

Power supply LED-

Switching current1 ... 150 mA

Assignment diagram-

Switching voltage-

Output voltage0 ... 1 V DC

Breaking capacity-

Type of output2 semiconductor outputs, p-s...

Output current-

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Current consumption40 mA

Safety classIII

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Risk time according to EN 60947-5-3-

Rated impulse withstand voltage Uimp0,5 kV

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Guard locking principle-

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Switching element-

Version-

Power supply LED-

Switching current1 ... 50 mA

Assignment diagram-

Switching voltage-

Output voltage0,8xUB ... UB V DC

Breaking capacity-

Type of outputp-switching, short circuit-p...

Output current-

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Current consumption40 mA

Safety classIII

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp0,5 kV

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Installation orientationAny

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Ambient temperature-20 ... +55 °C

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 116301?
The price of 116301 on MQ Automation is $1,483.64. Order now.

Out if stock but available for backorder.

116301 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

What can I help you find today?

Recommended parts