116300 Euchner Safety Accessories

116300 on MQ Automation
Euchner
  • 116300
  • 116300
  • 116300

Part#:116300

Alt. Part#:MGB-L0-ARA-AA2A1-S1-R-116300

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

116300 Euchner - Interlocking module MGB-L0-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    1.96652104 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • B10D
    0,13 x 10⁶
  • Performance Level
    PL e
  • PFHD
    3.7 x 10⁻⁹
  • Version
    Emergency stop
  • Category
    4
  • Product version number
    V4.0.0
  • Switching element
    2 pos. driven NC
  • Assignment diagram
    L1
  • Current consumption
    max.10 mA ((With no load on outputs OD, OT, OL, OI))
  • Operating voltage DC
    24 V DC -15% ... +10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Output current
    max.50 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Output voltage
    UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Safety class
    III
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Transponder coding
    Unicode
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    30 V
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP65
  • Mechanical life
    0,1 x 10⁶
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Installation orientation
    Door hinge DIN right
  • Weight
    0,75 kg
  • Switching frequency
    0,25 Hz
  • Connection
    Plug connector RC18 (X6)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 116300 on MQ Automation is $1,241.74. Order now.


About the product

Interlocking (without guard locking);Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode


Manufacturer warranty

116300 Euchner

$1,241.74

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,241.74

$1,241.74 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 116300 with other products

Weight

Series

Product Class

Mission time

B10D

Performance Level

PFHD

Version

Category

Product version number

Switching element

Assignment diagram

Current consumption

Operating voltage DC

Test-pulse interval

Test pulses

Output current

Type of output

Power supply LED

Breaking capacity

Output voltage

Safety class

Switching current

Switching voltage

Transponder coding

Housing material

Risk time according to EN...

Discrepancy time

Rated impulse withstand v...

Rated insulation voltage ...

Degree of contamination (...

Ambient temperature

Degree of protection

Mechanical life

Utilization category acc....

Installation orientation

Switching frequency

Connection

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Extension of risk time ac...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

116300
0 in stock
116300
Euchner

116300 Euchner - Interlocking module MGB-L0-ARA..., with 2 pushbuttons, emergency stop, incl. label ...

Weight1.96652104 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

B10D0,13 x 10⁶

Performance LevelPL e

PFHD3.7 x 10⁻⁹

VersionEmergency stop

Category4

Product version numberV4.0.0

Switching element2 pos. driven NC

Assignment diagramL1

Current consumptionmax.10 mA ((With no load on...

Operating voltage DC24 V DC -15% ... +10% ((R...

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Output currentmax.50 mA

Type of outputSemiconductor outputs, p-swi...

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Output voltageUA-2V ... UA V DC (Value at...

Safety classIII

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Transponder codingUnicode

Housing materialReinforced plastic; die-cast...

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui30 V

Degree of contamination (external, according to EN 60947-1)3

Ambient temperature-20 ... 55 °C

Degree of protectionIP65

Mechanical life0,1 x 10⁶

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Installation orientationDoor hinge DIN right

Switching frequency0,25 Hz

ConnectionPlug connector RC18 (X6)

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

VersionEmergency stop

Category4

Product version number-

Switching element2 pos. driven NC

Assignment diagram-

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Output current-

Type of output2 semiconductor outputs, p-s...

Power supply LED-

Breaking capacity-

Output voltage0 ... 1 V DC

Safety classIII

Switching current1 ... 150 mA

Switching voltage-

Transponder coding-

Housing materialFiber glass reinforced therm...

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Degree of contamination (external, according to EN 60947-1)3

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Installation orientationDoor hinge DIN right

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Mission time20

B10D-

Performance LevelPL e

PFHD1.9 x 10⁻⁹

Version-

Category4

Product version number-

Switching element-

Assignment diagram-

Current consumptionmax.50 mA (Without taking i...

Operating voltage DC24 V DC 15% ... 15% Regu...

Test-pulse intervalmin.140 ms

Test pulsesmax.1 ms (Applies for a loa...

Output current-

Type of outputp-switching, short circuit-p...

Power supply LED-

Breaking capacity-

Output voltage0,8 x UB ... UB V DC

Safety classIII

Switching currentmax.50 mA

Switching voltage-

Transponder coding-

Housing materialPlastic, PBT

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Ambient temperature-

Degree of protectionIP67

Mechanical life-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Installation orientationAny

Switching frequencymax.1 Hz

ConnectionConnection cable PUR, length...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R≤ 10

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speed-

Ready delay10 s

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 116300?
The price of 116300 on MQ Automation is $1,241.74. Order now.

Out if stock but available for backorder.

116300 Euchner - Interlocking module MGB-L0-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18

What can I help you find today?

Recommended parts