115138 Euchner Safety Accessories

115138 on MQ Automation
Euchner
  • 115138
  • 115138

Part#:115138

Alt. Part#:MGB-L1B-PNC-L-115138

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

115138 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, push-pull plug, RC12

Product Details

  • Weight
    7.62137134 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • B10D
    (According to manufacturer’s specifications)
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Performance Level
    PL e
  • Diagnostic Coverage (DC)
    99
  • Assignment diagram
    B1
  • Product version number
    V3.30.10
  • PFHD
    3.91 x 10⁻⁸
  • Category
    4
  • Color
    Red
  • Switching element
    1NO
  • Version
    Illuminated push buttons
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Safety class
    III
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Multicode
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Current consumption
    max.500 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Locking force FZh
    2000 N
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated insulation voltage Ui
    75 V
  • Connection
    Push-pull RJ45 (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Installation orientation
    Door hinge DIN left
  • Guard locking principle
    Closed-circuit current principle
  • Weight
    3,1 kg
  • Degree of protection
    IP54
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 115138 on MQ Automation is $3,018.55. Order now.


About the product

Guard locking with guard lock monitoring;3 illuminated pushbuttons;including adhesive labels;Push-pull plug;including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Integrated Profinet RT switch;Multicode


Manufacturer warranty

115138 Euchner

$3,018.55

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,018.55

$3,018.55 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 115138 with other products

Weight

Series

Product Class

Mission time

B10D

Safety Integrity Level

Performance Level

Diagnostic Coverage (DC)

Assignment diagram

Product version number

PFHD

Category

Color

Switching element

Version

Bus data protocol

Assured release distance ...

Safety class

Safety data protocol

Connecting cable

Fusing

Auxiliary voltage DC

Degree of contamination (...

Operating voltage DC

Transponder coding

EMC protection requiremen...

Current consumption

Rated impulse withstand v...

Locking force FZh

Maximum feed-in current i...

Rated insulation voltage ...

Connection

Installation orientation

Guard locking principle

Degree of protection

Housing material

Ambient temperature

Mechanical life

Switching frequency

Reaction time

Shock and vibration resis...

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN...

Solenoid duty cycle

Connection rating

Solenoid operating voltag...

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Operating current

Detent mechanism

Operating voltage

Selected product

115138
0 in stock
115138
Euchner

115138 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) wi...

Weight7.62137134 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

B10D(According to manufacturer’s...

Safety Integrity LevelSIL 3 (EN 62061:2005)

Performance LevelPL e

Diagnostic Coverage (DC)99

Assignment diagramB1

Product version numberV3.30.10

PFHD3.91 x 10⁻⁸

Category4

ColorRed

Switching element1NO

VersionIlluminated push buttons

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Safety classIII

Safety data protocolProfisafe (IEC 61784-3-3)

Connecting cableProfinet I/O cable, at least...

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingMulticode

EMC protection requirementsIn accordance with EN 61000-...

Current consumptionmax.500 mA

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh2000 N

Maximum feed-in current in the connection blockmax.4000 mA

Rated insulation voltage Ui75 V

ConnectionPush-pull RJ45 (X4 (The doc...

Installation orientationDoor hinge DIN left

Guard locking principleClosed-circuit current princ...

Degree of protectionIP54

Housing materialReinforced plastic, die-cast...

Ambient temperature-20 ... 55 °C

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Reaction timemax.550 ms Switch-off time...

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

B10D-

Safety Integrity Level-

Performance LevelPL e

Diagnostic Coverage (DC)-

Assignment diagram-

Product version number-

PFHD4.1 x 10 ⁻⁹

Category4

Color-

Switching element-

Version-

Bus data protocol-

Assured release distance Sar-

Safety classIII

Safety data protocol-

Connecting cable-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Reaction time-

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

Safety Integrity Level-

Performance LevelPL e

Diagnostic Coverage (DC)-

Assignment diagram-

Product version number-

PFHD4.1 x 10 ⁻⁹

Category4

Color-

Switching element2 pos. driven NC

VersionEmergency stop

Bus data protocol-

Assured release distance Sar-

Safety classIII

Safety data protocol-

Connecting cable-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh-

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5-pin

Installation orientationDoor hinge DIN right

Guard locking principle-

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Reaction time-

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating1 W

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 115138?
The price of 115138 on MQ Automation is $3,018.55. Order now.

Out if stock but available for backorder.

115138 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, push-pull plug, RC12

What can I help you find today?

Recommended parts