114054 Euchner Safety Accessories

114054 on MQ Automation
Euchner
  • 114054
  • 114054
  • 114054

Part#:114054

Alt. Part#:MGB-L1-ARA-AF8A1-S1-R-114054

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

114054 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    2.37217112 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • B10D
    0,13 x 10⁶
  • Switching element
    2 pos. driven NC + 1NO
  • Product version number
    V4.0.0
  • Assignment diagram
    L1
  • Special features
    With auxiliary contact
  • Version
    Emergency stop
  • Output current
    1 ... 200 mA
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Current consumption
    max.375 mA ((With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.5 ms
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 100 mA
  • Switching voltage
    5 ... 24 V
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Safety class
    III
  • Discrepancy time
    max.10 ms
  • Rated insulation voltage Ui
    30 V
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Locking force FZh
    2000 N
  • Installation orientation
    Door hinge DIN right
  • Weight
    0,75 kg
  • Switching frequency
    0,25 Hz
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Plug connector RC18 (X6)
  • Mechanical life
    0,1 x 10⁶
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP65

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114054 on MQ Automation is $1,450.53. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;1 pushbutton (illuminated, ye);incl. adhesive label;With plug connector RC18;Unicode


Manufacturer warranty

114054 Euchner

$1,450.53

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,450.53

$1,450.53 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 114054 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Category

B10D

Switching element

Product version number

Assignment diagram

Special features

Version

Output current

Output voltage

Type of output

Operating voltage DC

Current consumption

Test-pulse interval

Test pulses

Power supply LED

Breaking capacity

Switching current

Switching voltage

Transponder coding

Risk time according to EN...

Safety class

Discrepancy time

Rated insulation voltage ...

Degree of contamination (...

Utilization category acc....

Rated impulse withstand v...

Locking force FZh

Installation orientation

Switching frequency

Guard locking principle

Connection

Mechanical life

Housing material

Ambient temperature

Degree of protection

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

114054
0 in stock
114054
Euchner

114054 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbuttons, em...

Weight2.37217112 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

B10D0,13 x 10⁶

Switching element2 pos. driven NC + 1NO

Product version numberV4.0.0

Assignment diagramL1

Special featuresWith auxiliary contact

VersionEmergency stop

Output current1 ... 200 mA

Output voltageUB-2V ... UB V DC (Value at...

Type of outputSemiconductor outputs, p-swi...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Current consumptionmax.375 mA ((With energized...

Test-pulse intervalmin.100 ms

Test pulsesmax.5 ms

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Switching current1 ... 100 mA

Switching voltage5 ... 24 V

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Safety classIII

Discrepancy timemax.10 ms

Rated insulation voltage Ui30 V

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated impulse withstand voltage Uimp1,5 kV

Locking force FZh2000 N

Installation orientationDoor hinge DIN right

Switching frequency0,25 Hz

Guard locking principleClosed-circuit current princ...

ConnectionPlug connector RC18 (X6)

Mechanical life0,1 x 10⁶

Housing materialReinforced plastic; die-cast...

Ambient temperature-20 ... 55 °C

Degree of protectionIP65

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

B10D0,13 x 10⁶

Switching element2 pos. driven NC

Product version number-

Assignment diagram-

Special features-

VersionEmergency stop

Output current-

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Power supply LED-

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Transponder coding-

Risk time according to EN 60947-5-3-

Safety classIII

Discrepancy timemax.10 ms In acc. with EN ...

Rated insulation voltage Ui50 V

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh-

Installation orientationDoor hinge DIN right

Switching frequencymax.0,5 Hz

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

B10D-

Switching element-

Product version number-

Assignment diagram-

Special features-

Version-

Output current-

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Power supply LED-

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Discrepancy timemax.10 ms In acc. with EN ...

Rated insulation voltage Ui50 V

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Installation orientationAny

Switching frequencymax.0,5 Hz

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 114054?
The price of 114054 on MQ Automation is $1,450.53. Order now.