111684 Euchner Safety Proximity Sensors

111684 on MQ Automation
Euchner
  • 111684
  • 111684
  • 111684

Part#:111684

Alt. Part#:CET4-AR-CRA-CH-50X-SG-111684

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

111684 Euchner - Non-contact safety switch CET-AR-..., M12

Product Details

  • Weight
    2.79325354 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Category
    4
  • Switching delay from state change
    max.400 ms
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Turn-on time
    400 ms
  • Switching current
    1 ... 200 mA
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Output voltage
    UB-1,5V ... UB V DC
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Safety class
    III
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Locking force Fmax
    6500 N
  • Connection rating
    11 W
  • Current consumption
    80 mA
  • Fusing
    0,5 ... 8 A
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Guard locking principle
    Open-circuit current principle
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Approach speed
    max.20 m/min
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    10 s
  • Installation orientation
    Any (Preferably head downward)
  • Degree of freedom X
    ±5 mm
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Mechanical life
    1 x 10⁶
  • Weight
    1 kg
  • Degree of freedom Z
    ±4 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Ambient temperature
    -20 ... 55 °C
  • Degree of freedom Y
    ±5 mm
  • Housing material
    Die-cast aluminum

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 111684 on MQ Automation is $872.40. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Door monitoring output;Indication of the door position by LED;Approach direction A (delivery state)


Manufacturer warranty

111684 Euchner

$872.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$872.40

$872.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 111684 with other products

Weight

Series

Product Class

PFHD

Mission time

Performance Level

For the approval acc. to ...

Category

Switching delay from stat...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Turn-on time

Switching current

Risk time according to EN...

Output voltage

Type of output

Safety class

Connecting cable

Extension of risk time ac...

Switching load

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Utilization category acc....

Solenoid operating voltag...

Locking force Fmax

Connection rating

Current consumption

Fusing

Locking force FZh

Operating voltage DC

Guard locking principle

Connection

Approach speed

Switching frequency

Ready delay

Installation orientation

Degree of freedom X

Degree of protection

Mechanical life

Degree of freedom Z

Shock and vibration resis...

Ambient temperature

Degree of freedom Y

Housing material

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

111684
0 in stock
111684
Euchner

111684 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.79325354 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Switching delay from state changemax.400 ms

Repeat accuracy R10 %

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Turn-on time400 ms

Switching current1 ... 200 mA

Risk time according to EN 60947-5-3max.400 ms

Output voltageUB-1,5V ... UB V DC

Type of output2 semiconductor outputs, p-s...

Safety classIII

Connecting cable30V DC, 2A (For UL requirem...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (For altern...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Locking force Fmax6500 N

Connection rating11 W

Current consumption80 mA

Fusing0,5 ... 8 A

Locking force FZh5000 N (FZH = FMAX/1.3)

Operating voltage DC24 V DC -15% ... 10%

Guard locking principleOpen-circuit current princip...

Connection2 plug connectors M12, 5 and...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delay10 s

Installation orientationAny (Preferably head downwa...

Degree of freedom X±5 mm

Degree of protectionIP67 (Screwed tight plug co...

Mechanical life1 x 10⁶

Degree of freedom Z±4 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... 55 °C

Degree of freedom Y±5 mm

Housing materialDie-cast aluminum

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Switching delay from state change-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Switching current1 ... 50 mA

Risk time according to EN 60947-5-3max.260 ms

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Safety classIII

Connecting cable-

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Locking force Fmax3900 N

Connection rating6 W

Current consumption40 mA

Fusing0,25 ... 8 A

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Operating voltage DC24 V DC -15% ... 15% Rev...

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Degree of freedom X-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Degree of freedom Z-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of freedom Y-

Housing materialDie-cast zinc

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Switching delay from state change-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Switching current1 ... 150 mA

Risk time according to EN 60947-5-3-

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Safety classIII

Connecting cable-

Extension of risk time according to EN 60947-5-3 per device-

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Solenoid operating voltage DC-

Locking force Fmax-

Connection rating1 W

Current consumption40 mA

Fusing0,25 ... 8 A

Locking force FZh-

Operating voltage DC24 V DC -15% ... 15% Rev...

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Degree of freedom X-

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Degree of freedom Z-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Ambient temperature-20 ... +55 °C

Degree of freedom Y-

Housing materialFiber glass reinforced therm...

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 111684?
The price of 111684 on MQ Automation is $872.40. Order now.

Out if stock but available for backorder.

111684 Euchner - Non-contact safety switch CET-AR-..., M12

What can I help you find today?

Recommended parts