111683 Euchner Safety Proximity Sensors

111683 on MQ Automation
Euchner
  • 111683
  • 111683
  • 111683

Part#:111683

Alt. Part#:CET4-AR-CRA-AH-50X-SG-111683

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

111683 Euchner - Non-contact safety switch CET-AR-..., M12

Product Details

  • Weight
    2.52869914 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Performance Level
    PL e
  • Mission time
    20 y
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Repeat accuracy R
    10 %
  • Input voltage
    0 ... 1 V DC
  • Switching delay from state change
    max.400 ms
  • Discrepancy time
    max.10 ms
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Output voltage
    UB-1,5V ... UB V DC
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Switching current
    1 ... 200 mA
  • Safety class
    III
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    11 W
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Fusing
    0,25 ... 8 A
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Current consumption
    450 mA
  • Locking force Fmax
    6500 N
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Open-circuit current principle
  • Switching frequency
    max.0,5 Hz
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Installation orientation
    Any (Preferably head downward)
  • Ready delay
    10 s
  • Mechanical life
    1 x 10⁶
  • Degree of freedom Z
    ±4 mm
  • Weight
    1 kg
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Degree of freedom X
    ±5 mm
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Die-cast aluminum
  • Degree of freedom Y
    ±5 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 111683 on MQ Automation is $953.54. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Indication of the door position by LED;Teach-in input;Approach direction A (delivery state)


Manufacturer warranty

111683 Euchner

$953.54

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$953.54

$953.54 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 111683 with other products

Weight

Series

Product Class

PFHD

Performance Level

Mission time

Category

For the approval acc. to ...

Repeat accuracy R

Input voltage

Switching delay from stat...

Discrepancy time

Turn-on time

Risk time according to EN...

Off-state current Ir

Type of output

Output voltage

Extension of risk time ac...

Switching current

Safety class

Switching load

Connecting cable

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Solenoid operating voltag...

Fusing

Utilization category acc....

Operating voltage DC

Locking force FZh

Current consumption

Locking force Fmax

Approach speed

Guard locking principle

Switching frequency

Connection

Installation orientation

Ready delay

Mechanical life

Degree of freedom Z

Degree of protection

Degree of freedom X

Ambient temperature

Housing material

Degree of freedom Y

Shock and vibration resis...

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

111683
0 in stock
111683
Euchner

111683 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.52869914 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Performance LevelPL e

Mission time20 y

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Input voltage0 ... 1 V DC

Switching delay from state changemax.400 ms

Discrepancy timemax.10 ms

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Output voltageUB-1,5V ... UB V DC

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching current1 ... 200 mA

Safety classIII

Switching load24V DC, class 2 (For altern...

Connecting cable30V DC, 2A (For UL requirem...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating11 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 10%

Locking force FZh5000 N (FZH = FMAX/1.3)

Current consumption450 mA

Locking force Fmax6500 N

Approach speedmax.20 m/min

Guard locking principleOpen-circuit current princip...

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Installation orientationAny (Preferably head downwa...

Ready delay10 s

Mechanical life1 x 10⁶

Degree of freedom Z±4 mm

Degree of protectionIP67 (Screwed tight plug co...

Degree of freedom X±5 mm

Ambient temperature-20 ... 55 °C

Housing materialDie-cast aluminum

Degree of freedom Y±5 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Mission time20 y

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Input voltage-

Switching delay from state change-

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Off-state current Irmax.0,25 mA

Type of outputp-switching, short circuit-p...

Output voltage0,8xUB ... UB V DC

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching current1 ... 50 mA

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Current consumption40 mA

Locking force Fmax3900 N

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Ready delay8 s

Mechanical life1 x 10⁶

Degree of freedom Z-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Degree of freedom X-

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of freedom Y-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Mission time20 y

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Input voltage-

Switching delay from state change-

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Output voltage0 ... 1 V DC

Extension of risk time according to EN 60947-5-3 per device-

Switching current1 ... 150 mA

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Solenoid operating voltage DC-

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh-

Current consumption40 mA

Locking force Fmax-

Approach speedmax.20 m/min

Guard locking principle-

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Installation orientationDoor hinge DIN right

Ready delaymax.1 s

Mechanical life1 x 10⁶

Degree of freedom Z-

Degree of protectionIP65 (Screwed tight plug co...

Degree of freedom X-

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Degree of freedom Y-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 111683?
The price of 111683 on MQ Automation is $953.54. Order now.

Out if stock but available for backorder.

111683 Euchner - Non-contact safety switch CET-AR-..., M12

What can I help you find today?

Recommended parts