111103 Euchner Safety Locking Systems

111103 on MQ Automation
Euchner
  • 111103
  • 111103
  • 111103

Part#:111103

Alt. Part#:MGB-L1-ARA-AC4A1-S1-L-111103

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

111103 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, RC18

Product Details

  • Weight
    2.3809896 lb
  • Series
    MGB-AR
  • Product Class
    Safety System
  • Performance Level
    PL e
  • Mission time
    20 y
  • B10D
    0,13 x 10⁶
  • Product version number
    V4.0.0
  • PFHD
    3.7 x 10⁻⁹
  • Category
    4
  • Color
    white
  • Special features
    Printed
  • Switching element
    1NO
  • Assignment diagram
    L1
  • Version
    Illuminated push buttons
  • Power supply LED
    24 V DC
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Breaking capacity
    max.0,25 W
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Output current
    1 ... 200 mA
  • Test-pulse interval
    min.100 ms
  • Switching current
    1 ... 10 mA
  • Test pulses
    max.1 ms
  • Discrepancy time
    max.10 ms
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Switching voltage
    UA V
  • Transponder coding
    Unicode
  • Current consumption
    max.80 mA ((no load on outputs))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Locking force FZh
    2000 N
  • Connection
    Plug connector RC18 (X6)
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Door hinge DIN left
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Mechanical life
    0,1 x 10⁶
  • Guard locking principle
    Closed-circuit current principle
  • Degree of protection
    IP65
  • Weight
    0,75 kg
  • Switching frequency
    0,25 Hz

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 111103 on MQ Automation is $1,518.69. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated and printed);incl. adhesive labels;With plug connector RC18;Unicode


Manufacturer warranty

111103 Euchner

$1,518.69

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,518.69

$1,518.69 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 111103 with other products

Weight

Series

Product Class

Performance Level

Mission time

B10D

Product version number

PFHD

Category

Color

Special features

Switching element

Assignment diagram

Version

Power supply LED

Type of output

Breaking capacity

Output voltage

Output current

Test-pulse interval

Switching current

Test pulses

Discrepancy time

Operating voltage DC

Switching voltage

Transponder coding

Current consumption

Degree of contamination (...

Safety class

Utilization category acc....

Rated insulation voltage ...

Risk time according to EN...

Rated impulse withstand v...

Locking force FZh

Connection

Ambient temperature

Installation orientation

Housing material

Mechanical life

Guard locking principle

Degree of protection

Switching frequency

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

111103
0 in stock
111103
Euchner

111103 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, em...

Weight2.3809896 lb

SeriesMGB-AR

Product ClassSafety System

Performance LevelPL e

Mission time20 y

B10D0,13 x 10⁶

Product version numberV4.0.0

PFHD3.7 x 10⁻⁹

Category4

Colorwhite

Special featuresPrinted

Switching element1NO

Assignment diagramL1

VersionIlluminated push buttons

Power supply LED24 V DC

Type of outputSemiconductor outputs, p-swi...

Breaking capacitymax.0,25 W

Output voltageUB-2V ... UB V DC (Value at...

Output current1 ... 200 mA

Test-pulse intervalmin.100 ms

Switching current1 ... 10 mA

Test pulsesmax.1 ms

Discrepancy timemax.10 ms

Operating voltage DC24 V DC -15% ... 10% ((Re...

Switching voltageU<sub>A</sub> V

Transponder codingUnicode

Current consumptionmax.80 mA ((no load on outp...

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Risk time according to EN 60947-5-3max.350 ms

Rated impulse withstand voltage Uimp1,5 kV

Locking force FZh2000 N

ConnectionPlug connector RC18 (X6)

Ambient temperature-20 ... 55 °C

Installation orientationDoor hinge DIN left

Housing materialReinforced plastic; die-cast...

Mechanical life0,1 x 10⁶

Guard locking principleClosed-circuit current princ...

Degree of protectionIP65

Switching frequency0,25 Hz

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Performance LevelPL e

Mission time20 y

B10D0,13 x 10⁶

Product version number-

PFHD4.1 x 10 ⁻⁹

Category4

Color-

Special features-

Switching element2 pos. driven NC

Assignment diagram-

VersionEmergency stop

Power supply LED-

Type of output2 semiconductor outputs, p-s...

Breaking capacity-

Output voltage0 ... 1 V DC

Output current-

Test-pulse intervalmin.100 ms

Switching current1 ... 150 mA

Test pulsesmax.0,3 ms (Applies for a l...

Discrepancy timemax.10 ms In acc. with EN ...

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching voltage-

Transponder coding-

Current consumption40 mA

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Risk time according to EN 60947-5-3-

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Installation orientationDoor hinge DIN right

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Guard locking principle-

Degree of protectionIP65 (Screwed tight plug co...

Switching frequencymax.0,5 Hz

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Performance LevelPL e

Mission time20 y

B10D-

Product version number-

PFHD4.1 x 10 ⁻⁹

Category4

Color-

Special features-

Switching element-

Assignment diagram-

Version-

Power supply LED-

Type of outputp-switching, short circuit-p...

Breaking capacity-

Output voltage0,8xUB ... UB V DC

Output current-

Test-pulse intervalmin.140 ms

Switching current1 ... 50 mA

Test pulsesmax.1,0 ms (Applies for a l...

Discrepancy timemax.10 ms In acc. with EN ...

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching voltage-

Transponder coding-

Current consumption40 mA

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Ambient temperature-20 ... +55 °C

Installation orientationAny

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Guard locking principleClosed-circuit current princ...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching frequencymax.0,5 Hz

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 111103?
The price of 111103 on MQ Automation is $1,518.69. Order now.

Out if stock but available for backorder.

111103 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, RC18

What can I help you find today?

Recommended parts