110816 Euchner Safety Locking Systems

110816 on MQ Automation
Euchner

Part#:110816

Alt. Part#:MGB-CB-PN-110816

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

110816 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Product Details

  • Weight
    7.7175 lb
  • B10D
    0,13 x 10⁶
  • Diagnostic Coverage (DC)
    99
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Mission time
    20
  • PFHD
    4.1 x 10⁻⁸
  • Category
    4
  • Performance Level
    PL e
  • Product version number
    V3.30.10
  • Version
    Illuminated push buttons
  • Switching element
    1NO
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Fusing
    min.1 A Slow blow
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Assignment diagram
    C3
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Color
    white
  • Current consumption
    max.500 mA
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    75 V
  • Connection
    Push-pull power (X2 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Switching frequency
    0,25 Hz
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Installation orientation
    Any
  • Degree of protection
    IP54
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    2,7 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110816 on MQ Automation is $5,301.67. Order now.


Manufacturer warranty

110816 Euchner

$5,301.67

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$5,301.67

$5,301.67 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110816 with other products

Weight

B10D

Diagnostic Coverage (DC)

Safety Integrity Level

Mission time

PFHD

Category

Performance Level

Product version number

Version

Switching element

Safety data protocol

Auxiliary voltage DC

Fusing

Operating voltage DC

Assignment diagram

Bus data protocol

Color

Current consumption

Connecting cable

Degree of contamination (...

Safety class

EMC protection requiremen...

Maximum feed-in current i...

Rated impulse withstand v...

Rated insulation voltage ...

Connection

Switching frequency

Housing material

Reaction time

Installation orientation

Degree of protection

Ambient temperature

Shock and vibration resis...

Series

Product Class

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Mechanical life

Approach speed

Ready delay

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Risk time according to EN...

Extension of risk time ac...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

110816
0 in stock
110816
Euchner

110816 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

Weight7.7175 lb

B10D0,13 x 10⁶

Diagnostic Coverage (DC)99

Safety Integrity LevelSIL 3 (EN 62061:2005)

Mission time20

PFHD4.1 x 10⁻⁸

Category4

Performance LevelPL e

Product version numberV3.30.10

VersionIlluminated push buttons

Switching element1NO

Safety data protocolProfisafe (IEC 61784-3-3)

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Fusingmin.1 A Slow blow

Operating voltage DC24 V DC -15% ... 10% ((Re...

Assignment diagramC3

Bus data protocolProfinet (IEC 61158 type 10)

Colorwhite

Current consumptionmax.500 mA

Connecting cableProfinet I/O cable, at least...

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui75 V

ConnectionPush-pull power (X2 (The do...

Switching frequency0,25 Hz

Housing materialReinforced plastic, die-cast...

Reaction timemax.250 ms Switch-off time...

Installation orientationAny

Degree of protectionIP54

Ambient temperature-20 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Series-

Product Class-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Mechanical life-

Approach speed-

Ready delay-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

B10D0,13 x 10⁶

Diagnostic Coverage (DC)-

Safety Integrity Level-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

VersionEmergency stop

Switching element2 pos. driven NC

Safety data protocol-

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Assignment diagram-

Bus data protocol-

Color-

Current consumption40 mA

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Housing materialFiber glass reinforced therm...

Reaction time-

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

SeriesMGBS-P-I-AP

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Mechanical life1 x 10⁶

Approach speedmax.20 m/min

Ready delaymax.1 s

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

B10D-

Diagnostic Coverage (DC)-

Safety Integrity Level-

Mission time20

PFHD1.9 x 10⁻⁹

Category4

Performance LevelPL e

Product version number-

Version-

Switching element-

Safety data protocol-

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Assignment diagram-

Bus data protocol-

Color-

Current consumptionmax.50 mA (Without taking i...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

ConnectionConnection cable PUR, length...

Switching frequencymax.1 Hz

Housing materialPlastic, PBT

Reaction time-

Installation orientationAny

Degree of protectionIP67

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

SeriesCES-AR

Product ClassSafety System

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R≤ 10

Detent mechanism-

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Operating voltage-

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load-

Output voltage0,8 x UB ... UB V DC

Connection rating-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Overtravel-

Test-pulse intervalmin.140 ms

Extraction force-

Test pulsesmax.1 ms (Applies for a loa...

Actuating force-

Mechanical life-

Approach speed-

Ready delay10 s

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110816?
The price of 110816 on MQ Automation is $5,301.67. Order now.

Out if stock but available for backorder.

110816 Euchner - MULTIFUNCTIONAL GATE BOX COMPLETE

What can I help you find today?

Recommended parts