Part#:110860

Alt. Part#:MGB-L2-ARA-AD3A1-S1-R-110860

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

110860 Euchner - Locking module MGB-L2-ARA..., (guard locking by solenoid force) with 3 pushbuttons, RC18

Product Details

  • Weight
    2.3479203 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Category
    4
  • Performance Level
    PL e
  • Product version number
    V4.0.0
  • Switching element
    1NO
  • Color
    Blue
  • Assignment diagram
    L1
  • Version
    Illuminated push buttons
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Power supply LED
    24 V DC
  • Test pulses
    max.5 ms
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Current consumption
    max.80 mA ((no load on outputs))
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Discrepancy time
    max.10 ms
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Locking force FZh
    2000 N
  • Guard locking principle
    Open-circuit current principle
  • Installation orientation
    Door hinge DIN right
  • Switching frequency
    0,25 Hz
  • Connection
    Plug connector RC18 (X6)
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Mechanical life
    0,1 x 10⁶
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    0,75 kg
  • Degree of protection
    IP65

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110860 on MQ Automation is $1,484.72. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);1 pushbutton (illuminated, bu);1 pushbutton (illuminated, with button labeling “Unlocked,” wh);1 pushbutton (illuminated, with button labeling “Locked,” wh);With plug connector RC18;Unicode


Manufacturer warranty

110860 Euchner

$1,484.72

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,484.72

$1,484.72 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110860 with other products

Weight

Series

Product Class

Mission time

PFHD

Category

Performance Level

Product version number

Switching element

Color

Assignment diagram

Version

Output voltage

Output current

Type of output

Test-pulse interval

Power supply LED

Test pulses

Breaking capacity

Switching current

Switching voltage

Current consumption

Operating voltage DC

Transponder coding

Discrepancy time

Risk time according to EN...

Safety class

Degree of contamination (...

Rated impulse withstand v...

Utilization category acc....

Rated insulation voltage ...

Locking force FZh

Guard locking principle

Installation orientation

Switching frequency

Connection

Housing material

Mechanical life

Ambient temperature

Degree of protection

B10D

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

110860
0 in stock
110860
Euchner

110860 Euchner - Locking module MGB-L2-ARA..., (guard locking by solenoid force) with 3 pushbuttons,...

Weight2.3479203 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Category4

Performance LevelPL e

Product version numberV4.0.0

Switching element1NO

ColorBlue

Assignment diagramL1

VersionIlluminated push buttons

Output voltageUB-2V ... UB V DC (Value at...

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Power supply LED24 V DC

Test pulsesmax.5 ms

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Current consumptionmax.80 mA ((no load on outp...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.350 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Locking force FZh2000 N

Guard locking principleOpen-circuit current princip...

Installation orientationDoor hinge DIN right

Switching frequency0,25 Hz

ConnectionPlug connector RC18 (X6)

Housing materialReinforced plastic; die-cast...

Mechanical life0,1 x 10⁶

Ambient temperature-20 ... 55 °C

Degree of protectionIP65

B10D-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

Switching element2 pos. driven NC

Color-

Assignment diagram-

VersionEmergency stop

Output voltage0 ... 1 V DC

Output current-

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Power supply LED-

Test pulsesmax.0,3 ms (Applies for a l...

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh-

Guard locking principle-

Installation orientationDoor hinge DIN right

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

Product version number-

Switching element-

Color-

Assignment diagram-

Version-

Output voltage0,8xUB ... UB V DC

Output current-

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Power supply LED-

Test pulsesmax.1,0 ms (Applies for a l...

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Installation orientationAny

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

B10D-

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110860?
The price of 110860 on MQ Automation is $1,484.72. Order now.

Out if stock but available for backorder.

110860 Euchner - Locking module MGB-L2-ARA..., (guard locking by solenoid force) with 3 pushbuttons, RC18

What can I help you find today?

Recommended parts