110202 Euchner Safety Proximity Sensors

110202 on MQ Automation
Euchner
  • 110202
  • 110202
  • 110202

Part#:110202

Alt. Part#:CET4-AR-CRA-CH-50X-SH-110202

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

110202 Euchner - Non-contact safety switch CET-AR-..., RC18

Product Details

  • Weight
    2.60586084 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Performance Level
    PL e
  • Category
    4
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Switching delay from state change
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Turn-on time
    400 ms
  • Output voltage
    0 ... 1 V DC
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching current
    1 ... 200 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV2/CYJV8) or (CYJV/CYJV7))
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    80 mA
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Locking force Fmax
    6500 N
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Switching frequency
    max.0,5 Hz
  • Installation orientation
    Any (Preferably head downward)
  • Ready delay
    10 s
  • Mechanical life
    1 x 10⁶
  • Degree of freedom Z
    ±4 mm
  • Degree of freedom Y
    ±5 mm
  • Degree of protection
    IP65/IP67 (Screwed tight plug connector/mating component)
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    1 kg
  • Housing material
    Stainless steel
  • Degree of freedom X
    ±5 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110202 on MQ Automation is $872.40. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With plug connector M23 (RC18);Multicode;Door monitoring output;Approach direction A (delivery state)


Manufacturer warranty

110202 Euchner

$872.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$872.40

$872.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110202 with other products

Weight

Series

Product Class

PFHD

Mission time

Performance Level

Category

Repeat accuracy R

Discrepancy time

Risk time according to EN...

For the approval acc. to ...

Switching delay from stat...

Off-state current Ir

Turn-on time

Output voltage

Switching load

Type of output

Switching current

Extension of risk time ac...

Connecting cable

Safety class

Degree of contamination (...

Solenoid duty cycle

Connection rating

Fusing

Solenoid operating voltag...

Current consumption

EMC protection requiremen...

Operating voltage DC

Utilization category acc....

Locking force FZh

Locking force Fmax

Guard locking principle

Approach speed

Connection

Switching frequency

Installation orientation

Ready delay

Mechanical life

Degree of freedom Z

Degree of freedom Y

Degree of protection

Ambient temperature

Housing material

Degree of freedom X

Shock and vibration resis...

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

110202
0 in stock
110202
Euchner

110202 Euchner - Non-contact safety switch CET-AR-..., RC18

Weight2.60586084 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Repeat accuracy R10 %

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.400 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state changemax.400 ms

Off-state current Irmax.0,25 mA

Turn-on time400 ms

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (For altern...

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 200 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Connecting cable30V DC, 2A (For UL requirem...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating11 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption80 mA

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Operating voltage DC24 V DC -15% ... 10%

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh5000 N (FZH = FMAX/1.3)

Locking force Fmax6500 N

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Connection1 plug connector M23, 19-pin...

Switching frequencymax.0,5 Hz

Installation orientationAny (Preferably head downwa...

Ready delay10 s

Mechanical life1 x 10⁶

Degree of freedom Z±4 mm

Degree of freedom Y±5 mm

Degree of protectionIP65/IP67 (Screwed tight pl...

Ambient temperature-20 ... 55 °C

Housing materialStainless steel

Degree of freedom X±5 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3max.260 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Output voltage0,8xUB ... UB V DC

Switching load24V DC, class 2 (Alternativ...

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Connecting cable-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Installation orientationAny

Ready delay8 s

Mechanical life1 x 10⁶

Degree of freedom Z-

Degree of freedom Y-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of freedom X-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3-

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Off-state current Irmax.0,25 mA

Turn-on timemax.400 ms

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Extension of risk time according to EN 60947-5-3 per device-

Connecting cable-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Current consumption40 mA

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Ready delaymax.1 s

Mechanical life1 x 10⁶

Degree of freedom Z-

Degree of freedom Y-

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Degree of freedom X-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110202?
The price of 110202 on MQ Automation is $872.40. Order now.

Out if stock but available for backorder.

110202 Euchner - Non-contact safety switch CET-AR-..., RC18

What can I help you find today?

Recommended parts