109945 Euchner Safety Accessories

109945 on MQ Automation
Euchner
  • 109945
  • 109945
  • 109945

Part#:109945

Alt. Part#:MGB-L2-ARA-BA1A1-M-109945

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

109945 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) without control or indicator, guard lock monitoring switched off

Product Details

  • Weight
    2.0502966 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Product version number
    V4.0.0
  • Category
    4
  • Output current
    1 ... 200 mA
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Current consumption
    max.375 mA ((With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
  • Test pulses
    max.1 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Safety class
    III
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    30 V
  • Locking force FZh
    2000 N
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Degree of protection
    IP65
  • Ambient temperature
    -20 ... 55 °C
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Installation orientation
    Door hinge DIN right
  • Weight
    0,75 kg
  • Connection
    Cable entries M20x1.5
  • Guard locking principle
    Open-circuit current principle
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 109945 on MQ Automation is $878.46. Order now.


About the product

Guard locking with guard lock monitoring (switched off);Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);With cable entry;Unicode


Manufacturer warranty

109945 Euchner

$878.46

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$878.46

$878.46 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 109945 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Product version number

Category

Output current

Output voltage

Current consumption

Test pulses

Type of output

Test-pulse interval

Operating voltage DC

Transponder coding

Risk time according to EN...

Discrepancy time

Safety class

Connection cross-section

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Locking force FZh

Utilization category acc....

Degree of protection

Ambient temperature

Mechanical life

Switching frequency

Installation orientation

Connection

Guard locking principle

Housing material

For the approval acc. to ...

Additional feature

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

109945
0 in stock
109945
Euchner

109945 Euchner - Locking module MGB-L2-ARA... (guard locking by solenoid force) without control or i...

Weight2.0502966 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Product version numberV4.0.0

Category4

Output current1 ... 200 mA

Output voltageUB-2V ... UB V DC (Value at...

Current consumptionmax.375 mA ((With energized...

Test pulsesmax.1 ms

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Safety classIII

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui30 V

Locking force FZh2000 N

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Degree of protectionIP65

Ambient temperature-20 ... 55 °C

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Installation orientationDoor hinge DIN right

ConnectionCable entries M20x1.5

Guard locking principleOpen-circuit current princip...

Housing materialReinforced plastic; die-cast...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Product version number-

Category4

Output current-

Output voltage0,8xUB ... UB V DC

Current consumption40 mA

Test pulsesmax.1,0 ms (Applies for a l...

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Installation orientationAny

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Product version number-

Category4

Output current-

Output voltage0 ... 1 V DC

Current consumption40 mA

Test pulsesmax.0,3 ms (Applies for a l...

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Safety classIII

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Locking force FZh-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 109945?
The price of 109945 on MQ Automation is $878.46. Order now.