109941 Euchner Safety Proximity Sensors

109941 on MQ Automation
Euchner
  • 109941
  • 109941
  • 109941

Part#:109941

Alt. Part#:CET2-AR-CRA-CH-50F-SG-C2312-109941

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

109941 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

Product Details

  • Weight
    2.84616442 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Discrepancy time
    max.10 ms
  • PFHD
    3.1 x 10⁻⁹
  • Repeat accuracy R
    10 %
  • Category
    4
  • Off-state current Ir
    max.0,25 mA
  • Output current
    1 ... 200 mA
  • Performance Level
    PL e
  • Safety class
    III
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Output voltage
    UB-1,5V ... UB V DC (Values at a switching current of 50mA without taking into account the cable lengths)
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Fusing
    0,5 ... 8 A
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Locking force FZh
    5000 N
  • Current consumption
    450 mA
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Locking force Fmax
    6500 N
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Guard locking principle
    Open-circuit current principle
  • Degree of freedom X
    ±5 mm
  • Approach speed
    max.20 m/min
  • Ready delay
    10 s
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Housing material
    Stainless steel
  • Switching frequency
    max.0,5 Hz
  • Installation orientation
    Any (Preferably head downward)
  • Weight
    1 kg
  • Mechanical life
    1 x 10⁶
  • Ambient temperature
    -20 ... 55 °C
  • Degree of freedom Z
    ±4 mm
  • Degree of freedom Y
    ±5 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 109941 on MQ Automation is $1,015.63. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Escape release, 105 mm long;Approach direction A (delivery state)


Manufacturer warranty

109941 Euchner

$1,015.63

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,015.63

$1,015.63 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 109941 with other products

Weight

Series

Product Class

Mission time

Turn-on time

Risk time according to EN...

For the approval acc. to ...

Discrepancy time

PFHD

Repeat accuracy R

Category

Off-state current Ir

Output current

Performance Level

Safety class

Switching load

Output voltage

Extension of risk time ac...

Type of output

Degree of contamination (...

Solenoid duty cycle

Connection rating

EMC protection requiremen...

Solenoid operating voltag...

Fusing

Utilization category acc....

Locking force FZh

Current consumption

Operating voltage DC

Locking force Fmax

Connection

Guard locking principle

Degree of freedom X

Approach speed

Ready delay

Degree of protection

Housing material

Switching frequency

Installation orientation

Mechanical life

Ambient temperature

Degree of freedom Z

Degree of freedom Y

Additional feature

Switching current

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

Shock and vibration resis...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

109941
0 in stock
109941
Euchner

109941 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

Weight2.84616442 lb

SeriesCET-AR

Product ClassSafety System

Mission time20 y

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms

PFHD3.1 x 10⁻⁹

Repeat accuracy R10 %

Category4

Off-state current Irmax.0,25 mA

Output current1 ... 200 mA

Performance LevelPL e

Safety classIII

Switching load24V DC, class 2 (For altern...

Output voltageUB-1,5V ... UB V DC (Values...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Type of outputSemiconductor outputs, p-swi...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating11 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,5 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh5000 N

Current consumption450 mA

Operating voltage DC24 V DC -15% ... 10%

Locking force Fmax6500 N

Connection2 plug connectors M12, 5 and...

Guard locking principleOpen-circuit current princip...

Degree of freedom X±5 mm

Approach speedmax.20 m/min

Ready delay10 s

Degree of protectionIP67 (Screwed tight plug co...

Housing materialStainless steel

Switching frequencymax.0,5 Hz

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Ambient temperature-20 ... 55 °C

Degree of freedom Z±4 mm

Degree of freedom Y±5 mm

Additional feature-

Switching current-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms In acc. with EN ...

PFHD4.1 x 10 ⁻⁹

Repeat accuracy R10 %

Category4

Off-state current Irmax.0,25 mA

Output current-

Performance LevelPL e

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating6 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax3900 N

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Degree of freedom X-

Approach speedmax.20 m/min

Ready delay8 s

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Switching frequencymax.0,5 Hz

Installation orientationAny

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of freedom Z-

Degree of freedom Y-

Additional featureEscape release actuated by p...

Switching current1 ... 50 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms In acc. with EN ...

PFHD4.1 x 10 ⁻⁹

Repeat accuracy R10 %

Category4

Off-state current Irmax.0,25 mA

Output current-

Performance LevelPL e

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Extension of risk time according to EN 60947-5-3 per device-

Type of output2 semiconductor outputs, p-s...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

Connection rating1 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC-

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Locking force FZh-

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax-

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Degree of freedom X-

Approach speedmax.20 m/min

Ready delaymax.1 s

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Degree of freedom Z-

Degree of freedom Y-

Additional feature-

Switching current1 ... 150 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

109941
0 in stock
109941
Euchner

109941 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

Weight2.84616442 lb

SeriesCET-AR

Product ClassSafety System

Mission time20 y

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Discrepancy timemax.10 ms

PFHD3.1 x 10⁻⁹

Repeat accuracy R10 %

Category4

Off-state current Irmax.0,25 mA

Output current1 ... 200 mA

Performance LevelPL e

Safety classIII

Switching load24V DC, class 2 (For altern...

Output voltageUB-1,5V ... UB V DC (Values...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Type of outputSemiconductor outputs, p-swi...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Connection rating11 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Fusing0,5 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Locking force FZh5000 N

Current consumption450 mA

Operating voltage DC24 V DC -15% ... 10%

Locking force Fmax6500 N

Connection2 plug connectors M12, 5 and...

Guard locking principleOpen-circuit current princip...

Degree of freedom X±5 mm

Approach speedmax.20 m/min

Ready delay10 s

Degree of protectionIP67 (Screwed tight plug co...

Housing materialStainless steel

Switching frequencymax.0,5 Hz

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Ambient temperature-20 ... 55 °C

Degree of freedom Z±4 mm

Degree of freedom Y±5 mm

Additional feature-

Switching current-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 109941?
The price of 109941 on MQ Automation is $1,015.63. Order now.

Out if stock but available for backorder.

109941 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

What can I help you find today?

Recommended parts